Validation of a gas chromatography-triple quadrupole mass spectrometry method for confirmatory analysis of dioxins and dioxin-like polychlorobiphenyls in feed following new EU Regulation 709/2014

被引:53
作者
L'Homme, B. [1 ]
Scholl, G. [1 ]
Eppe, G. [1 ]
Focant, J. -F. [1 ]
机构
[1] Univ Liege, CART, Dept Chem, Organ & Biol Analyt Chem Grp, B-4000 Liege, Belgium
关键词
Dioxins; Gas chromatography coupled to tandem-in-space triple quadrupole mass spectrometry (GC-QQQMS/MS); Vegetable oil; Validation; EU Regulation 709/2014; POLYCHLORINATED-BIPHENYLS; DIETARY-INTAKE; SAMPLES; FOOD; FOODSTUFFS; EXPOSURE; PCBS;
D O I
10.1016/j.chroma.2014.12.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The European Regulations laying down methods of sampling and analysis for the EU official control of levels of polychlorodibenzo-p-dioxins (PCDDs), polychloro-dibenzofurans (PCDFs), dioxin-like (DL) and non dioxin-like (NDL) PCBs in food and feed have been recently amended by EU Regulation Nos. 589/2014 and 709/2014. A major update is the recognition of gas chromatography (GC) triple quadrupole mass spectrometry (GC-QQQMS/MS) as a confirmatory tool for checking compliance with maximum levels (ML). These revisions have been initiated since this technology now exhibits similar performances to GC (magnetic sector) high resolution mass spectrometry (GC-HRMS). In this paper, we show a fully validated method for PCDD/Fs and DL-PCBs analysis in feed material of plant origin (vegetable oil) using GC-QQQMS/MS following the dedicated EU Regulation 709/2014. We show that individual analytical criteria (selectivity, linearity, quant/qual MRM transitions, accuracy around ML of 1.50 ng WHO(2005)TEQ/kg, within-lab reproducibility, robustness, and background subtraction) meet the strict requirements set by the EU Regulation. We also propose a clear interpretation of instrumental limit of quantitation (iLOQ) as a 'performance-LOQ', defined in a specific way for GC-QQQMS/MS, and method limit of quantitation (mLOQ) as 'real-LOQ' that is used to report bound results. Eventually, the evaluation of measurement uncertainty, following a top-down approach and data produced with our method, demonstrates similar results than with GC-HRMS, thus offering a reliable alternative to the standard method for vegetable oil. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 158
页数:10
相关论文
共 31 条
[1]  
[Anonymous], OFFIC J EUR COMMUN L
[2]  
[Anonymous], 2002, OFFIC J EUR COMMUN L, VL6, P45
[3]  
[Anonymous], 2002, OFFIC J EUR COMMUN L, VL209, P15
[4]  
[Anonymous], 2001, OFFIC J EUR COMMUN L, VL77, P1
[5]  
[Anonymous], 2011, OFFIC J EUR COMMUN L, VL320, P18
[6]  
[Anonymous], 2006, OFFIC J EUR COMMUN L, VL328, P14
[7]  
[Anonymous], 2012, OFFIC J EUR COMMUN L, V115, P1
[8]  
[Anonymous], 2004, OFFIC J EUR COMMUN L, VL158, P7
[9]  
Behnisch P.A., 2001, ORGANOHALOGEN COMPD, V50, P59
[10]  
Ellison SLR., 2012, Quantifying uncertainty in analytical measurement