Comparative Study of In Situ Techniques to Enlarge Gold Nanoparticles for Highly Sensitive Lateral Flow Immunoassay of SARS-CoV-2

被引:21
作者
Panferov, Vasily G. [1 ]
Byzova, Nadezhda A. [1 ]
Biketov, Sergey F. [2 ]
Zherdev, Anatoly, V [1 ]
Dzantiev, Boris B. [1 ]
机构
[1] Russian Acad Sci, AN Bach Inst Biochem, Res Ctr Biotechnol, Moscow 119071, Russia
[2] State Res Ctr Appl Microbiol & Biotechnol, Obolensk 142279, Moscow Region, Russia
来源
BIOSENSORS-BASEL | 2021年 / 11卷 / 07期
关键词
immunochromatography; point-of-care testing; limit of detection; antigen test; coronavirus; receptor-binding domain; silver enhancement; gold enhancement; galvanic replacement; spike protein; AU NANOPARTICLES; SILVER; ENHANCEMENT; ASSAYS;
D O I
10.3390/bios11070229
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three techniques were compared for lowering the limit of detection (LOD) of the lateral flow immunoassay (LFIA) of the receptor-binding domain of severe acute respiratory syndrome-related coronavirus 2 (SARS-CoV-2) based on the post-assay in situ enlargement of Au nanoparticles (Au NPs) on a test strip. Silver enhancement (growth of a silver layer over Au NPs-Au@Ag NPs) and gold enhancement (growth of a gold layer over Au NPs) techniques and the novel technique of galvanic replacement of Ag by Au in Au@Ag NPs causing the formation of Au@Ag-Au NPs were performed. All the enhancements were performed on-site after completion of the conventional LFIA and maintained equipment-free assay. The assays demonstrated lowering of LODs in the following rows: 488 pg/mL (conventional LFIA with Au NPs), 61 pg/mL (silver enhancement), 8 pg/mL (galvanic replacement), and 1 pg/mL (gold enhancement). Using gold enhancement as the optimal technique, the maximal dilution of inactivated SARS-CoV-2-containing samples increased 500 times. The developed LFIA provided highly sensitive and rapid (8 min) point-of-need testing.
引用
收藏
页数:13
相关论文
共 49 条
[1]   Increased sensitivity of lateral flow immunoassay for ochratoxin A through silver enhancement [J].
Anfossi, L. ;
Di Nardo, F. ;
Giovannoli, C. ;
Passini, C. ;
Baggiani, C. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (30) :9859-9867
[2]   Multiplex Lateral Flow Immunoassay: An Overview of Strategies towards High-throughput Point-of-Need Testing [J].
Anfossi, Laura ;
Di Nardo, Fabio ;
Cavalera, Simone ;
Giovannoli, Cristina ;
Baggiani, Claudio .
BIOSENSORS-BASEL, 2018, 9 (01)
[3]  
[Anonymous], TECHNOTES
[4]   Functionalized Au@Ag-Au nanoparticles as an optical and SERS dual probe for lateral flow sensing [J].
Bai, Tingting ;
Wang, Meng ;
Cao, Min ;
Zhang, Juan ;
Zhang, Kangzhen ;
Zhou, Ping ;
Liu, Zhengxia ;
Liu, Ying ;
Guo, Zhirui ;
Lu, Xiang .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (09) :2291-2303
[5]   Sensitivity enhancement in lateral flow assays: a systems perspective [J].
Bishop, Joshua D. ;
Hsieh, Helen V. ;
Gasperino, David J. ;
Weigl, Bernhard H. .
LAB ON A CHIP, 2019, 19 (15) :2486-2499
[6]   Comparison of two rapid influenza A/B test kits with reference methods showing high specificity and sensitivity for influenza A infection [J].
Booth, S ;
Baleriola, C ;
Rawlinson, WD .
JOURNAL OF MEDICAL VIROLOGY, 2006, 78 (05) :619-622
[7]   Direct observation of the nanoscale Kirkendall effect during galvanic replacement reactions [J].
Chee, See Wee ;
Tan, Shu Fen ;
Baraissov, Zhaslan ;
Bosman, Michel ;
Mirsaidov, Utkur .
NATURE COMMUNICATIONS, 2017, 8
[8]   Immunochromatographic methods in food analysis [J].
Dzantiev, Boris B. ;
Byzova, Nadezhda A. ;
Urusov, Alexandr E. ;
Zherdev, Anatoly V. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 55 :81-93
[9]   Electron Compensation Effect Suppressed Silver Ion Release and Contributed Safety of Au@Ag Core-Shell Nanoparticles [J].
Feng, Yanlin ;
Wang, Guorui ;
Chang, Yun ;
Cheng, Yan ;
Sun, Bingbing ;
Wang, Liming ;
Chen, Chunying ;
Zhang, Haiyuan .
NANO LETTERS, 2019, 19 (07) :4478-4489
[10]   CONTROLLED NUCLEATION FOR REGULATION OF PARTICLE-SIZE IN MONODISPERSE GOLD SUSPENSIONS [J].
FRENS, G .
NATURE-PHYSICAL SCIENCE, 1973, 241 (105) :20-22