Monitoring the integrity of the cement-metal interface of total joint components in vitro using acoustic emission and ultrasound

被引:33
作者
Davies, JP [1 ]
Tse, MK [1 ]
Harris, WH [1 ]
机构
[1] MASSACHUSETTS GEN HOSP,ORTHOPAED BIOMECH LAB,BOSTON,MA 02114
关键词
debonding; cement-metal interface; loosening; acoustic emission; ultrasound;
D O I
10.1016/S0883-5403(96)80115-X
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Debonding of the cement-metal interface of cemented femoral components of total hip arthroplasty has been shown from clinical and autopsy material to be a common occurrence. Experimentally debonding has been shown to increase markedly the strains in the adjacent cement mantle. Studies of autopsy-retrieved specimens demonstrate that debonding of the cement-metal interface is a key initiating event in loosening of cemented femoral components of total hip arthroplasty. However, both the radiographic and autopsy evidence of cement-metal interfacial debonding exist after the fact, that is, after debonding has occurred. The lack of prospective data showing that debonding does indeed occur under physiologic loading and occurs prior to other forms of failure of fixation leaves uncertain the issue of debonding and its role in initiating loosening of cemented femoral components. Knowing when, where, and to what extent the cement-metal interface debonds is critical information in understanding the process of loosening of cemented femoral components. Such information would contribute to improving the durability of stems and improving cementing techniques. In this study, the two nondestructive techniques of acoustic emission and ultrasonic evaluation of the cement-metal interface of cemented femoral stems of total hip arthroplasty were combined to investigate when, where, and to what extent cement-metal debonding occurred in vitro in simulated femurs loaded physiologically in fatigue in simulated single-leg stance. Debonding of the cement-metal interface of a cemented femoral component in this model was both an initiating event and a major mechanism of compromise of the cement-metal interface. Additional acoustic emission signals arose from cracks that developed in the cement.
引用
收藏
页码:594 / 601
页数:8
相关论文
共 22 条
[1]  
[Anonymous], NONDESTRUCTIVE TESTI
[2]  
BOURNE RB, 1984, CLIN ORTHOP RELAT R, V183, P12
[3]   MICROMOTION OF CEMENTED AND UNCEMENTED FEMORAL COMPONENTS [J].
BURKE, DW ;
OCONNOR, DO ;
ZALENSKI, EB ;
JASTY, M ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (01) :33-37
[4]   CENTRIFUGATION AS A METHOD OF IMPROVING TENSILE AND FATIGUE PROPERTIES OF ACRYLIC BONE-CEMENT [J].
BURKE, DW ;
GATES, EI ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (08) :1265-1273
[5]   CEMENT STRAIN-MEASUREMENT SURROUNDING LOOSE AND WELL-FIXED FEMORAL COMPONENT STEMS [J].
CROWNINSHIELD, RD ;
TOLBERT, JR .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (05) :819-828
[6]  
Davies J P, 1989, J Arthroplasty, V4, P15, DOI 10.1016/S0883-5403(89)80048-8
[7]  
Davies Jeffrey P., 1993, Clinical Materials, V12, P121, DOI 10.1016/0267-6605(93)90061-B
[8]   IN-VITRO EVALUATION OF BONDING OF THE CEMENT-METAL INTERFACE OF A TOTAL HIP FEMORAL COMPONENT USING ULTRASOUND [J].
DAVIES, JP ;
TSE, MK ;
HARRIS, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (03) :335-338
[9]  
HAMPTON S J, 1981, Orthopaedic Transactions, V5, P284
[10]   A 3-DIMENSIONAL NONLINEAR FINITE-ELEMENT STUDY OF THE EFFECT OF CEMENT-PROSTHESIS DEBONDING IN CEMENTED FEMORAL TOTAL HIP COMPONENTS [J].
HARRIGAN, TP ;
HARRIS, WH .
JOURNAL OF BIOMECHANICS, 1991, 24 (11) :1047-1058