Evaluation of an automated breast 3D-ultrasound system by comparing it with hand-held ultrasound (HHUS) and mammography

被引:36
|
作者
Golatta, Michael [1 ]
Baggs, Christina [1 ]
Schweitzer-Martin, Mirjam [1 ]
Domschke, Christoph [1 ]
Schott, Sarah [1 ]
Harcos, Aba [1 ]
Scharf, Alexander [1 ]
Junkermann, Hans [1 ]
Rauch, Geraldine [2 ]
Rom, Joachim [1 ]
Sohn, Christof [1 ]
Heil, Joerg [1 ]
机构
[1] Univ Breast Unit, D-69120 Heidelberg, Germany
[2] Heidelberg Univ, Inst Med Biometry & Informat, Heidelberg, Germany
关键词
Ultrasound; Breast; Automated three-dimensional breast ultrasound; 3D scanning; BI-RADS((R)); VOLUME SCANNER; LESION DETECTION; DENSE BREASTS; SONOGRAPHY; CANCER; AGREEMENT; DIAGNOSIS; US; CLASSIFICATION; CARCINOMA;
D O I
10.1007/s00404-014-3509-9
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Automated three-dimensional (3D) breast ultrasound (US) systems are meant to overcome the shortcomings of hand-held ultrasound (HHUS). The aim of this study is to analyze and compare clinical performance of an automated 3D-US system by comparing it with HHUS, mammography and the clinical gold standard (defined as the combination of HHUS, mammography and-if indicated-histology). Nine hundred and eighty three patients (=1,966 breasts) were enrolled in this monocentric, explorative and prospective cohort study. All examinations were analyzed blinded to the patientsA ' history and to the results of the routine imaging. The agreement of automated 3D-US with HHUS, mammography and the gold standard was assessed with kappa statistics. Sensitivity, specificity and positive and negative predictive value were calculated to assess the test performance. Blinded to the results of the gold standard the agreement between automated 3D-US and HHUS or mammography was fair, given by a Kappa coefficient of 0.31 (95 % CI [0.26;0.36], p < 0.0001) and 0.25 (95 % CI [0.2;0.3], p < 0.0001), respectively. Our results showed a high negative predictive value (NPV) of 98 %, a high specificity of 85 % and a sensitivity of 74 % based on the cases with US-guided biopsy. Including the cases where the lesion was seen in a second-look automated 3D-US the sensitivity improved to 84 % (NPV = 99 %, specificity = 85 %). The results of this study let us suggest, that automated 3D-US might be a helpful new tool in breast imaging, especially in screening.
引用
收藏
页码:889 / 895
页数:7
相关论文
共 50 条
  • [41] Correlation Factors Analysis of Breast Cancer Tumor Volume Doubling Time Measured by 3D-Ultrasound
    Zhang, Shuying
    Ding, Yan
    Zhu, Qiaoying
    Wang, Cheng
    Wu, Pengxi
    Dong, Ji
    MEDICAL SCIENCE MONITOR, 2017, 23 : 3147 - 3153
  • [42] Comparison of mammography, digital breast tomosynthesis, automated breast ultrasound, magnetic resonance imaging in evaluation of residual tumor after neoadjuvant chemotherapy
    Park, Jiyoon
    Chae, Eun Young
    Cha, Joo Hee
    Shin, Hee Jung
    Choi, Woo Jung
    Choi, Young-Wook
    Kim, Hak Hee
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 108 : 261 - 268
  • [43] Computer aided detection in automated 3-D breast ultrasound images: a survey
    Ehsan Kozegar
    Mohsen Soryani
    Hamid Behnam
    Masoumeh Salamati
    Tao Tan
    Artificial Intelligence Review, 2020, 53 : 1919 - 1941
  • [44] COMPARATIVE STUDY OF AUTOMATED BREAST 3-D ULTRASOUND AND HANDHELD B-MODE ULTRASOUND FOR DIFFERENTIATION OF BENIGN AND MALIGNANT BREAST MASSES
    Chen, Lin
    Chen, Yue
    Diao, Xue-Hong
    Fang, Liang
    Pang, Yun
    Cheng, Ai-Qun
    Li, Wei-Ping
    Wang, Yi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (10) : 1735 - 1742
  • [45] Automatic Nipple Detection on 3D Images of an Automated Breast Ultrasound System (ABUS)
    Moghaddam, Mandana Javanshir
    Tan, Tao
    Karssemeijer, Nico
    Platel, Bram
    MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034
  • [46] Validation of radiologists' findings by computer-aided detection (CAD) software in breast cancer detection with automated 3D breast ultrasound: a concept study in implementation of artificial intelligence software
    van Zelst, Jan C. M.
    Tan, Tao
    Mann, Ritse M.
    Karssemeijer, Nico
    ACTA RADIOLOGICA, 2020, 61 (03) : 312 - 320
  • [47] Comparison between different imaging techniques in the evaluation of malignant breast lesions: can 3D ultrasound be useful?
    Clauser, Paola
    Londero, Viviana
    Como, Giuseppe
    Girometti, Rossano
    Bazzocchi, Massimo
    Zuiani, Chiara
    RADIOLOGIA MEDICA, 2014, 119 (04): : 240 - 248
  • [48] Computer-Aided Lesion Diagnosis in Automated 3-D Breast Ultrasound Using Coronal Spiculation
    Tan, Tao
    Platel, Bram
    Huisman, Henkjan
    Sanchez, Clara I.
    Mus, Roel
    Karssemeijer, Nico
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (05) : 1034 - 1042
  • [49] Image guided breast biopsy using 3D ultrasound and stereotactic mammography
    Surry, KJM
    Mills, GR
    Bevan, K
    Downey, DB
    Fenster, A
    MEDICAL IMAGING 2003: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2003, 5029 : 376 - 383
  • [50] Automated Breast Ultrasound System for Breast Cancer Evaluation: Diagnostic Performance of the Two-View Scan Technique in Women with Small Breasts
    Kwon, Bo Ra
    Chang, Jung Min
    Kim, Soo Yeon
    Lee, Su Hyun
    Kim, Soo-Yeon
    Lee, So Min
    Cho, Nariya
    Moon, Woo Kyung
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (01) : 25 - 32