Evaluation of an automated breast 3D-ultrasound system by comparing it with hand-held ultrasound (HHUS) and mammography

被引:36
|
作者
Golatta, Michael [1 ]
Baggs, Christina [1 ]
Schweitzer-Martin, Mirjam [1 ]
Domschke, Christoph [1 ]
Schott, Sarah [1 ]
Harcos, Aba [1 ]
Scharf, Alexander [1 ]
Junkermann, Hans [1 ]
Rauch, Geraldine [2 ]
Rom, Joachim [1 ]
Sohn, Christof [1 ]
Heil, Joerg [1 ]
机构
[1] Univ Breast Unit, D-69120 Heidelberg, Germany
[2] Heidelberg Univ, Inst Med Biometry & Informat, Heidelberg, Germany
关键词
Ultrasound; Breast; Automated three-dimensional breast ultrasound; 3D scanning; BI-RADS((R)); VOLUME SCANNER; LESION DETECTION; DENSE BREASTS; SONOGRAPHY; CANCER; AGREEMENT; DIAGNOSIS; US; CLASSIFICATION; CARCINOMA;
D O I
10.1007/s00404-014-3509-9
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Automated three-dimensional (3D) breast ultrasound (US) systems are meant to overcome the shortcomings of hand-held ultrasound (HHUS). The aim of this study is to analyze and compare clinical performance of an automated 3D-US system by comparing it with HHUS, mammography and the clinical gold standard (defined as the combination of HHUS, mammography and-if indicated-histology). Nine hundred and eighty three patients (=1,966 breasts) were enrolled in this monocentric, explorative and prospective cohort study. All examinations were analyzed blinded to the patientsA ' history and to the results of the routine imaging. The agreement of automated 3D-US with HHUS, mammography and the gold standard was assessed with kappa statistics. Sensitivity, specificity and positive and negative predictive value were calculated to assess the test performance. Blinded to the results of the gold standard the agreement between automated 3D-US and HHUS or mammography was fair, given by a Kappa coefficient of 0.31 (95 % CI [0.26;0.36], p < 0.0001) and 0.25 (95 % CI [0.2;0.3], p < 0.0001), respectively. Our results showed a high negative predictive value (NPV) of 98 %, a high specificity of 85 % and a sensitivity of 74 % based on the cases with US-guided biopsy. Including the cases where the lesion was seen in a second-look automated 3D-US the sensitivity improved to 84 % (NPV = 99 %, specificity = 85 %). The results of this study let us suggest, that automated 3D-US might be a helpful new tool in breast imaging, especially in screening.
引用
收藏
页码:889 / 895
页数:7
相关论文
共 50 条
  • [31] Automated 3D Ultrasound as an Adjunct to Screening Mammography Programs in Dense Breast: Literature Review and Metanalysis
    Gatta, Gianluca
    Somma, Francesco
    Sardu, Celestino
    De Chiara, Marco
    Massafra, Raffaella
    Fanizzi, Annarita
    La Forgia, Daniele
    Cuccurullo, Vincenzo
    Iovino, Francesco
    Clemente, Alfredo
    Marfella, Raffaele
    Di Grezia, Graziella
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (12):
  • [32] Development of a hand-held 3D photoacoustic imaging system for breast cancer detection
    Al-Aabed, Hazem
    Roumeliotis, Michael
    Carson, Jeffrey J. L.
    PHOTONICS NORTH 2010, 2010, 7750
  • [33] Radiologist-performed hand-held ultrasound screening at average risk of breast cancer: results from a single health screening center
    Chang, Jung Min
    Koo, Hye Ryoung
    Moon, Woo Kyung
    ACTA RADIOLOGICA, 2015, 56 (06) : 652 - 658
  • [34] SONOGRAPHIC PHENOTYPES OF MOLECULAR SUBTYPES OF INVASIVE DUCTAL CANCER IN AUTOMATED 3-D BREAST ULTRASOUND
    van Zelst, Jan C. M.
    Balkenhol, Maschenka
    Tan, Tao
    Rutten, Matthieu
    Imhof-Tas, Mechli
    Bult, Peter
    Karssemeijer, Nico
    Mann, Ritse M.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (09) : 1820 - 1828
  • [35] Radiologists' performance in the detection of benign and malignant masses with 3D automated breast ultrasound (ABUS)
    Chang, Jung Min
    Moon, Woo Kyung
    Cho, Nariya
    Park, Jeong Seon
    Kim, Seung Ja
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 78 (01) : 99 - 103
  • [36] Automated breast ultrasound system (ABUS): can it replace mammography as a screening tool?
    Abd Elkhalek, Yasser, I
    Bassiouny, Ahmed M.
    Hamid, Rasha Wessam Abdel Rahman Abdel
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2019, 50 (01)
  • [37] Automated breast ultrasound system (ABUS): can it replace mammography as a screening tool?
    Yasser I. Abd Elkhalek
    Ahmed M. Bassiouny
    Rasha Wessam Abdel Rahman Abdel Hamid
    Egyptian Journal of Radiology and Nuclear Medicine, 50
  • [38] Breast-density assessment with hand-held ultrasound: A novel biomarker to assess breast cancer risk and to tailor screening?
    Sergio J. Sanabria
    Orcun Goksel
    Katharina Martini
    Serafino Forte
    Thomas Frauenfelder
    Rahel A. Kubik-Huch
    Marga B. Rominger
    European Radiology, 2018, 28 : 3165 - 3175
  • [39] Computer aided detection in automated 3-D breast ultrasound images: a survey
    Kozegar, Ehsan
    Soryani, Mohsen
    Behnam, Hamid
    Salamati, Masoumeh
    Tan, Tao
    ARTIFICIAL INTELLIGENCE REVIEW, 2020, 53 (03) : 1919 - 1941
  • [40] Automated 3-D Ultrasound Elastography of the Breast: An In Vivo Validation Study
    Hendriks, Gijs A. G. M.
    Chen, Chuan
    Mann, Ritse
    Hansen, Hendrik H. G.
    de Korte, Chris L.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (03) : 358 - 363