Evaluation of an automated breast 3D-ultrasound system by comparing it with hand-held ultrasound (HHUS) and mammography

被引:36
|
作者
Golatta, Michael [1 ]
Baggs, Christina [1 ]
Schweitzer-Martin, Mirjam [1 ]
Domschke, Christoph [1 ]
Schott, Sarah [1 ]
Harcos, Aba [1 ]
Scharf, Alexander [1 ]
Junkermann, Hans [1 ]
Rauch, Geraldine [2 ]
Rom, Joachim [1 ]
Sohn, Christof [1 ]
Heil, Joerg [1 ]
机构
[1] Univ Breast Unit, D-69120 Heidelberg, Germany
[2] Heidelberg Univ, Inst Med Biometry & Informat, Heidelberg, Germany
关键词
Ultrasound; Breast; Automated three-dimensional breast ultrasound; 3D scanning; BI-RADS((R)); VOLUME SCANNER; LESION DETECTION; DENSE BREASTS; SONOGRAPHY; CANCER; AGREEMENT; DIAGNOSIS; US; CLASSIFICATION; CARCINOMA;
D O I
10.1007/s00404-014-3509-9
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Automated three-dimensional (3D) breast ultrasound (US) systems are meant to overcome the shortcomings of hand-held ultrasound (HHUS). The aim of this study is to analyze and compare clinical performance of an automated 3D-US system by comparing it with HHUS, mammography and the clinical gold standard (defined as the combination of HHUS, mammography and-if indicated-histology). Nine hundred and eighty three patients (=1,966 breasts) were enrolled in this monocentric, explorative and prospective cohort study. All examinations were analyzed blinded to the patientsA ' history and to the results of the routine imaging. The agreement of automated 3D-US with HHUS, mammography and the gold standard was assessed with kappa statistics. Sensitivity, specificity and positive and negative predictive value were calculated to assess the test performance. Blinded to the results of the gold standard the agreement between automated 3D-US and HHUS or mammography was fair, given by a Kappa coefficient of 0.31 (95 % CI [0.26;0.36], p < 0.0001) and 0.25 (95 % CI [0.2;0.3], p < 0.0001), respectively. Our results showed a high negative predictive value (NPV) of 98 %, a high specificity of 85 % and a sensitivity of 74 % based on the cases with US-guided biopsy. Including the cases where the lesion was seen in a second-look automated 3D-US the sensitivity improved to 84 % (NPV = 99 %, specificity = 85 %). The results of this study let us suggest, that automated 3D-US might be a helpful new tool in breast imaging, especially in screening.
引用
收藏
页码:889 / 895
页数:7
相关论文
共 50 条
  • [21] Is there an extraclinical value of automated breast volume scanner compared with hand-held ultrasound? A pilot study
    Zhan, Jia
    Diao, Xue-Hong
    Pang, Yun
    Wang, Yan
    Chen, Lin
    Chen, Yue
    MEDICINE, 2017, 96 (37)
  • [22] First Evaluation of the Diagnostic Accuracy of an Automated 3D Ultrasound System in a Breast Screening Setting
    Stoeblen, Frank
    Landt, Solveig
    Stelkens-Gebhardt, Ruth
    Sehouli, Jalid
    Rezai, Mahdi
    Kuemmel, Sherko
    ANTICANCER RESEARCH, 2011, 31 (08) : 2569 - 2574
  • [23] Dependability of Automated Breast Ultrasound (ABUS) in Assessing Breast Imaging Reporting and Data System (BI-RADS) Category and Size of Malignant Breast Lesions Compared with Handheld Ultrasound (HHUS) and Mammography (MG)
    Chen, He
    Han, Ming
    Jing, Hui
    Liu, Zhao
    Shang, Haitao
    Wang, Qiucheng
    Cheng, Wen
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 9193 - 9202
  • [24] Classification of Breast Lesions in Automated 3D breast Ultrasound
    Tan, Tao
    Huisman, Henkjan
    Platel, Bram
    Grivignee, Andre
    Mus, Roel
    Karssemeijer, Nico
    MEDICAL IMAGING 2011: COMPUTER-AIDED DIAGNOSIS, 2011, 7963
  • [25] Multiplanar Reconstructions of 3D Automated Breast Ultrasound Improve Lesion Differentiation by Radiologists
    Van Zelst, Jan C. M.
    Platel, Bram
    Karssemeijer, Nico
    Mann, Ritse M.
    ACADEMIC RADIOLOGY, 2015, 22 (12) : 1489 - 1496
  • [26] Performance of hand-held whole-breast ultrasound based on BI-RADS in women with mammographically negative dense breast
    Ji Hyun Youk
    Eun-Kyung Kim
    Min Jung Kim
    Jin Young Kwak
    Eun Ju Son
    European Radiology, 2011, 21 : 667 - 675
  • [27] 3D Automated Breast Ultrasound System: Comparison of Interpretation Time of Senior Versus Junior Radiologist
    Arslan, Aydan
    Ertas, Gokhan
    Aribal, Erkin
    EUROPEAN JOURNAL OF BREAST HEALTH, 2019, 15 (03) : 153 - 157
  • [28] Breast-density assessment with hand-held ultrasound: A novel biomarker to assess breast cancer risk and to tailor screening?
    Sanabria, Sergio J.
    Goksel, Orcun
    Martini, Katharina
    Forte, Serafino
    Frauenfelder, Thomas
    Kubik-Huch, Rahel A.
    Rominger, Marga B.
    EUROPEAN RADIOLOGY, 2018, 28 (08) : 3165 - 3175
  • [29] VALUE OF HAND-HELD ULTRASOUND IN THE DIFFERENTIAL DIAGNOSIS AND ACCURATE BREAST IMAGING REPORTING AND DATA SYSTEM SUBCLASSIFICATION OF COMPLEX CYSTIC AND SOLID BREAST LESIONS
    Xiang, Huiling
    Tang, Guoxue
    Li, Yin
    Liu, Ying
    Liu, Lixian
    Lin, Xi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (05) : 1111 - 1118
  • [30] Comparison between automated breast volume scanner (ABVS) versus hand-held ultrasound as a second look procedure after magnetic resonance imaging
    Girometti, Rossano
    Zanotel, Martina
    Londero, Viviana
    Bazzocchi, Massimo
    Zuiani, Chiara
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3767 - 3775