Introduction Adequate fluid loading is the first step of hemodynamic optimization in cardiac patients undergoing surgery. Neither a clinical approach alone nor conventional parameters like central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP) are thought to be sufficient for recognizing fluid deficiency or overload. The aim of this study was to evaluate the suitability of CVP, PCWP, global end-diastolic volume index (GEDVI), pulse pressure variation (PPV), and stroke volume variation (SVV) for predicting changes in the cardiac index (CI) and stroke volume index (SVI) after sternotomy. Methods In 40 patients, CVP, PCWP, GEDVI, PPV, SVV, and the CI were measured at two points of time. One measurement was performed after inducing anesthesia and one after sternotomy. Results A significant increase in heart rate, CI, and GEDVI was observed during the study period. CVP, SVV, and PPV decreased significantly. There were no significant correlations between CVP and PCWP and changes in CI. In contrast, GEDVI, SVV, and PPV significantly correlated with CI changes. Only relative changes of GEDVI, SVV, and PPV predicted changes in SVI. Conclusion During cardiac surgery and especially after sternotomy, CVP and PCWP are not suitable for monitoring fluid status. Direct volume measurement like GEDVI and dynamic volume responsive measurements like SVV and PPV may be more suitable for monitoring the volume status of patients, particularly under open-chest conditions.
引用
收藏
页数:7
相关论文
共 30 条
  • [11] Intrathoracic blood volume as an end point in resuscitation of the severely burned:: An observational study of 24 patients
    Holm, C
    Melcer, B
    Hörbrand, F
    Wörl, HH
    von Donnersmarck, GH
    Mühlbauer, W
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 48 (04) : 728 - 734
  • [12] Current practice of hemodynamic monitoring and vasopressor and inotropic therapy in post-operative cardiac surgery patients in Germany: results from a postal survey
    Kastrup, M.
    Markewitz, A.
    Spies, C.
    Carl, M.
    Erb, J.
    Grosse, J.
    Schirmer, U.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2007, 51 (03) : 347 - 358
  • [13] The influence of positive end-expiratory pressure on stroke volume variation and central blood volume during open and closed chest conditions
    Kubitz, Jens C.
    Annecke, Thorsten
    Kemming, Gregor I.
    Forkl, Stefanie
    Kronas, Nils
    Goetz, Alwin E.
    Reuter, Daniel A.
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 30 (01) : 90 - 95
  • [14] Central venous pressure, pulmonary artery occlusion pressure, intrathoracic blood volume, and right ventricular end-diastolic volume as indicators of cardiac preload
    LichtwarckAschoff, M
    Beale, R
    Pfeiffer, UJ
    [J]. JOURNAL OF CRITICAL CARE, 1996, 11 (04) : 180 - 188
  • [15] Assessment of cardiac preload and left ventricular function under increasing levels of positive end-expiratory pressure
    Luecke, T
    Roth, H
    Herrmann, P
    Joachim, A
    Weisser, G
    Pelosi, P
    Quintel, M
    [J]. INTENSIVE CARE MEDICINE, 2004, 30 (01) : 119 - 126
  • [16] Changes in central venous pressure with vasoactive drug injections in humans
    Martin, EA
    Charkoudian, N
    [J]. CLINICAL AUTONOMIC RESEARCH, 2005, 15 (02) : 121 - 125
  • [17] Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis
    Marx, G
    Cope, T
    McCrossan, L
    Swaraj, S
    Cowan, C
    Mostafa, SM
    Wenstone, R
    Leuwer, M
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 (02) : 132 - 138
  • [18] Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock
    Michard, F
    Alaya, S
    Zarka, W
    Bahloul, M
    Richard, C
    Teboul, JL
    [J]. CHEST, 2003, 124 (05) : 1900 - 1908
  • [19] Assessing fluid responsiveness by the systolic pressure variation in mechanically ventilated patients - Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension
    Perel, A
    [J]. ANESTHESIOLOGY, 1998, 89 (06) : 1309 - 1310
  • [20] Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators
    Preisman, S
    Kogan, S
    Berkenstadt, H
    Perel, A
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2005, 95 (06) : 746 - 755