High-speed dual-beam, crossed line-scanning fluorescence microscope with a point confocal resolution

被引:6
作者
Jeong, Hyun-Woo [1 ,2 ]
Kim, Hyung-Jin [3 ]
Eun, Jung [4 ]
Heo, Seungjin [5 ,6 ]
Lim, Mikyoung [7 ]
Cho, Yong-Hoon [5 ,6 ]
Kim, Beop-Min [3 ]
机构
[1] Eulji Univ, Coll Hlth Sci, Dept Biomed Engn, Songnam, South Korea
[2] Eulji Univ, Sch Med, Songnam, South Korea
[3] Korea Univ, Coll Hlth Sci, Sch Biomed Engn, Seoul, South Korea
[4] Korea Adv Inst Sci & Technol, Dept Elect Engn, Taejon 305701, South Korea
[5] Korea Adv Inst Sci & Technol, Grad Sch Nanosci & Technol WCU, Dept Phys, Taejon 305701, South Korea
[6] Korea Adv Inst Sci & Technol, Inst NanoCentury, Taejon 305701, South Korea
[7] Korea Adv Inst Sci & Technol, Dept Math Sci, Taejon 305701, South Korea
关键词
IN-VIVO; ILLUMINATION;
D O I
10.1364/AO.54.003811
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Line-scanning microscopes are often used to overcome the limited scanning speed of conventional point-scanning confocal microscopes, at the cost, however, of spatial resolution. In this paper, we present a dual-beam fluorescence line-scanning microscope that can restore the original confocal resolution. This microscope forms two orthogonal line foci in the object plane with perpendicular scanning directions, which create two line-scan images of the same area. From these images, the real noise and confocal characteristics are analyzed. Based on this information, we developed an image restoration algorithm to produce a final image with spatial resolution comparable to that of a conventional point-scanning confocal microscope. This algorithm was derived with the total variation regularization, and the critical image restoration factor for the algorithm was determined via an iterative process. Our results indicate that the intrinsic resolution limit of line-scanning microscopes can be overcome without subsequent deterioration in spatial resolution. (C) 2015 Optical Society of America
引用
收藏
页码:3811 / 3816
页数:6
相关论文
共 28 条
  • [1] USE OF CONFOCAL IMAGING IN THE STUDY OF BIOLOGICAL STRUCTURES
    AMOS, WB
    WHITE, JG
    FORDHAM, M
    [J]. APPLIED OPTICS, 1987, 26 (16): : 3239 - 3243
  • [2] 3-DIMENSIONAL CHROMATIN DISTRIBUTION IN NEURO-BLASTOMA NUCLEI SHOWN BY CONFOCAL SCANNING LASER MICROSCOPY
    BRAKENHOFF, GJ
    VANDERVOORT, HTM
    VANSPRONSEN, EA
    LINNEMANS, WAM
    NANNINGA, N
    [J]. NATURE, 1985, 317 (6039) : 748 - 749
  • [3] 3-DIMENSIONAL IMAGING BY CONFOCAL SCANNING FLUORESCENCE MICROSCOPY
    BRAKENHOFF, GJ
    VANDERVOORT, HTM
    VANSPRONSEN, EA
    NANNINGA, N
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1986, 483 : 405 - 415
  • [4] CONFOCAL IMAGING WITH BILATERAL SCANNING AND ARRAY DETECTORS
    BRAKENHOFF, GJ
    VISSCHER, K
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1992, 165 : 139 - 146
  • [5] Random transverse motion-induced spatial compounding for fiber bundle imaging
    Cheon, Gyeong Woo
    Cha, Jaepyeong
    Kang, Jin U.
    [J]. OPTICS LETTERS, 2014, 39 (15) : 4368 - 4371
  • [6] DEPTH RESPONSE OF CONFOCAL OPTICAL MICROSCOPES
    CORLE, TR
    CHOU, CH
    KINO, GS
    [J]. OPTICS LETTERS, 1986, 11 (12) : 770 - 772
  • [7] Cushion J, 2003, CLIN EXP OPHTHALMOL, V31, P241
  • [8] DMD-based LED-illumination Super-resolution and optical sectioning microscopy
    Dan, Dan
    Lei, Ming
    Yao, Baoli
    Wang, Wen
    Winterhalder, Martin
    Zumbusch, Andreas
    Qi, Yujiao
    Xia, Liang
    Yan, Shaohui
    Yang, Yanlong
    Gao, Peng
    Ye, Tong
    Zhao, Wei
    [J]. SCIENTIFIC REPORTS, 2013, 3
  • [9] Richardson-Lucy algorithm with total variation regularization for 3D confocal microscope deconvolution
    Dey, N
    Blanc-Feraud, L
    Zimmer, C
    Roux, P
    Kam, Z
    Olivo-Marin, JC
    Zerubia, J
    [J]. MICROSCOPY RESEARCH AND TECHNIQUE, 2006, 69 (04) : 260 - 266
  • [10] Dey N., 2004, 5272 INRIA SOPH ANT