Body Fluid Cell Counts by Automated Methods

被引:36
作者
Sandhaus, Linda M. [1 ]
机构
[1] Univ Hosp, Case Med Ctr, Dept Pathol, Cleveland, OH 44106 USA
关键词
Cell counting; Body fluids; Automated body fluid analysis; Hematology analyzers; ACUTE LYMPHOBLASTIC-LEUKEMIA; TRAUMATIC LUMBAR PUNCTURE; CEREBROSPINAL-FLUID; SYSMEX XE-5000; BLOOD-CELLS; HEMATOLOGY ANALYZER; PERFORMANCE EVALUATION; LEUKOCYTE COUNTS; WHITE; CHILDREN;
D O I
10.1016/j.cll.2014.10.003
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Automated cell counting for body fluids is gradually replacing manual cell counting by hemocytometer. Automation offers potential benefits of improved accuracy, efficiency, and standardization. The addition of body fluid modes to some hematology analyzers adapts the technology and software to meet the particular requirements of body fluid analysis. However, the functional sensitivity for low cell counts currently limits applicability of automated methods to all types of body fluid. Microscopic review is indicated when malignancy is a diagnostic consideration.
引用
收藏
页码:93 / +
页数:12
相关论文
共 50 条
[31]   Cell counting of body fluids: comparison between three automated haematology analysers and the manual microscope method [J].
Danise, P. ;
Maconi, M. ;
Rovetti, A. ;
Avino, D. ;
Di Palma, A. ;
Pirofalo, M. Gerardo ;
Esposito, C. .
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2013, 35 (06) :608-613
[32]   Automated vs. manual cerebrospinal fluid cell counts: a work and cost analysis comparing the Sysmex XE-5000 and the Fuchs-Rosenthal manual counting chamber [J].
Zimmermann, M. ;
Ruprecht, K. ;
Kainzinger, F. ;
Heppner, F. L. ;
Weimann, A. .
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2011, 33 (06) :629-637
[33]   Validation of reflex testing rules and establishment of a new workflow for body fluid cell analysis using a Sysmex XN-550 automatic hematology analyzer [J].
Cho, Y-U ;
You, E. ;
Jang, S. ;
Park, C-J .
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 (03) :258-267
[34]   A multicenter evaluation of the Iris iQ200 automated urine microscopy analyzer Body Fluids Module and comparison with hemacytometer cell counts [J].
Butch, Anthony W. ;
Wises, Porntip K. ;
Wah, David T. ;
Gornet, Terrie G. ;
Fritsche, Herbert A. .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 129 (03) :445-450
[35]   Automated Analysis of Cerebrospinal Fluid Cells Using Commercially Available Blood Cell Analysis Devices-A Critical Appraisal [J].
Wick, Manfred ;
Gross, Catharina C. ;
Tumani, Hayrettin ;
Wildemann, Brigitte ;
Stangel, Martin .
CELLS, 2021, 10 (05)
[36]   Performance evaluation and result comparison of the automated hematology analyzers Abbott CD 3700, Sysmex XE 2100 and Coulter LH 750 for cell counts in serous fluids [J].
Yang, Dagan ;
Zhou, Yunxian ;
Chen, Baode .
CLINICA CHIMICA ACTA, 2013, 419 :113-118
[37]   Determination of Mammalian Cell Counts, Cell Size and Cell Health Using the Moxi Z Mini Automated Cell Counter [J].
Dittami, Gregory M. ;
Sethi, Manju ;
Rabbitt, Richard D. ;
Ayliffe, H. Edward .
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2012, (64)
[38]   Development and evaluation of automated synovial fluid total cell count on an Iris iQ® 200 for identifying patients at risk of septic arthritis [J].
d'Epenoux, L. Ruffier ;
Fayoux, E. ;
Bemer, P. ;
Biering, V. ;
Bonte, A. ;
Elaiba, Y. ;
Robert, M. ;
Guillouzouic, A. ;
Tessier, E. ;
Persyn, E. ;
Corvec, S. .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2023, 42 (08) :1031-1036
[39]   Improving reliability of live/dead cell counting through automated image mosaicing [J].
Piccinini, Filippo ;
Tesei, Anna ;
Paganelli, Giulia ;
Zoli, Wainer ;
Bevilacqua, Alessandro .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2014, 117 (03) :448-463
[40]   Comparison between automated and microscopic analysis in body fluids cytology [J].
Bottini, P. V. ;
Pompeo, D. B. ;
Souza, M. I. ;
Garlipp, C. R. .
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2015, 37 (02) :e16-e18