Body Fluid Cell Counts by Automated Methods

被引:36
|
作者
Sandhaus, Linda M. [1 ]
机构
[1] Univ Hosp, Case Med Ctr, Dept Pathol, Cleveland, OH 44106 USA
关键词
Cell counting; Body fluids; Automated body fluid analysis; Hematology analyzers; ACUTE LYMPHOBLASTIC-LEUKEMIA; TRAUMATIC LUMBAR PUNCTURE; CEREBROSPINAL-FLUID; SYSMEX XE-5000; BLOOD-CELLS; HEMATOLOGY ANALYZER; PERFORMANCE EVALUATION; LEUKOCYTE COUNTS; WHITE; CHILDREN;
D O I
10.1016/j.cll.2014.10.003
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Automated cell counting for body fluids is gradually replacing manual cell counting by hemocytometer. Automation offers potential benefits of improved accuracy, efficiency, and standardization. The addition of body fluid modes to some hematology analyzers adapts the technology and software to meet the particular requirements of body fluid analysis. However, the functional sensitivity for low cell counts currently limits applicability of automated methods to all types of body fluid. Microscopic review is indicated when malignancy is a diagnostic consideration.
引用
收藏
页码:93 / +
页数:12
相关论文
共 50 条
  • [1] Automated Cerebrospinal Fluid Cell Counts Using the New Body Fluid Mode of Sysmex UF-1000i
    Buoro, Sabrina
    Esposito, Sara Apassiti
    Alessio, MariaGrazia
    Crippa, Alberto
    Ottomano, Cosimo
    Lippi, Giuseppe
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2016, 30 (05) : 381 - 391
  • [2] Performance evaluation of automated cell counts compared with reference methods for body fluid analysis
    Seghezzi, Michela
    Previtali, Giulia
    Moioli, Valentina
    Alessio, Maria Grazia
    Guerra, Giovanni
    Buoro, Sabrina
    DIAGNOSIS, 2022, 9 (03) : 369 - 378
  • [3] A New Automated Technology for Cerebrospinal Fluid Cell Counts Comparison of Accuracy and Clinical Impact of GloCyte, Sysmex XN, and Manual Methods
    Sandhaus, Linda M.
    Dillman, Christine A.
    Hinkle, Warren P.
    MacKenzie, Julie M.
    Hong, George
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2017, 147 (05) : 507 - 514
  • [4] Automated white blood cell counts in cerebrospinal fluid using the body fluid mode on the platform Sysmex XE-5000
    Li, Aihong
    Gronlund, Elisabeth
    Brattsand, Goran
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2014, 74 (08) : 673 - 680
  • [5] Accuracy of automated analyzers for the estimation of CSF cell counts: A systematic review and meta-analysis
    Waldrop, Greer E.
    Cocuzzo, Kaitlyn
    Schneider, Colleen L.
    Kim, Carla Y.
    Goetz, Teddy G.
    Chomba, Mashina S.
    Delaurentis, Clare E.
    Smithgall, Marie C.
    Francis, Richard O.
    Thakur, Kiran T.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2024, 46 (02) : 234 - 242
  • [6] Automated Cerebrospinal Fluid Cell Counts Using the Sysmex XE-5000
    Sandhaus, Linda M.
    Ciarlini, Pedro
    Kidric, Diane
    Dillman, Christine
    O'Riordan, Mary Ann
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2010, 134 (05) : 734 - 738
  • [7] Automated cell count in body fluids: a review
    Alcaide Martin, Maria Jose
    Altimira Queral, Laura
    Sahuquillo Frias, Laura
    Valina Amado, Laura
    Merino, Anna
    de Guadiana-Romualdo, Luis Garcia
    ADVANCES IN LABORATORY MEDICINE-AVANCES EN MEDICINA DE LABORATORIO, 2021, 2 (02): : 149 - 161
  • [8] Evaluation of the Sysmex XE-5000 for automated body fluid and cerebrospinal fluid analysis
    Ho, G.
    Keutgens, A.
    Huwart, A.
    Tassin, F.
    Gothot, A.
    IMMUNO-ANALYSE & BIOLOGIE SPECIALISEE, 2011, 26 (5-6): : 256 - 263
  • [9] Gaining Efficiency in the Laboratory - Automated Body Fluid Cell Counts: Evaluation of the Body Fluid Application on the Sysmex XE-5000 Hematology Analyzer
    Williams, James E.
    Walters, Jeri
    Kabb, Kimberley
    LABMEDICINE, 2011, 42 (07): : 395 - 401
  • [10] Preliminary evaluation of UF-5000 Body Fluid Mode for automated cerebrospinal fluid cell counting
    Seghezzi, Michela
    Manenti, Barbara
    Previtali, Giulia
    Alessio, Maria Grazia
    Dominoni, Paola
    Buoro, Sabrina
    CLINICA CHIMICA ACTA, 2017, 473 : 133 - 138