Optical coherence tomography and 3-dimensional confocal structured imaging system-guided femtosecond laser capsulotomy versus manual continuous curvilinear capsulorhexis

被引:57
作者
Mastropasqua, Leonardo [1 ]
Toto, Lisa [1 ]
Mattei, Peter A. [1 ]
Vecchiarino, Luca [1 ]
Mastropasqua, Alessandra [5 ]
Navarra, Riccardo [2 ]
Di Nicola, Marta [3 ,4 ]
Nubile, Mario [1 ]
机构
[1] Univ G DAnnunzio, Ophthalmol Clin, I-66100 Chieti, Italy
[2] Univ G DAnnunzio, Dept Med & Sci Ageing, Dept Neurosci & Imaging, I-66100 Chieti, Italy
[3] Univ G DAnnunzio, Inst Adv Biomed Technol, I-66100 Chieti, Italy
[4] Univ G DAnnunzio, Dept Expt & Clin Sci, Lab Biostat, I-66100 Chieti, Italy
[5] Univ Rome, Ophthalm Clin, Rome, Italy
关键词
INTRAOCULAR-LENS TILT; CATARACT-SURGERY; ANTERIOR CAPSULOTOMY; DECENTRATION; CAPSULORRHEXIS; IMPLANTATION; PARAMETERS; PIECE;
D O I
10.1016/j.jcrs.2014.05.032
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the features of capsulotomy obtained during femtosecond laser assisted cataract surgery with those of continuous curvilinear capsulorhexis (CCC) obtained using a standard manual technique. SETTING: Ophthalmology Clinic, Department of Medicine and Science of Ageing, University G. D'Annunzio Chieti-Pescara, Chieti, Italy. DESIGN: Prospective randomized clinical study. METHODS: Candidates for cataract extraction were randomized into 1 of 3 groups as follows: Lensx femtosecond laser assisted cataract surgery capsulotomy (laser group 1), Lensar femtosecond laser assisted cataract surgery capsulotomy (laser group 2), and manual CCC (manual group). RESULTS: Each group comprised 30 eyes (30 patients). The capsulotomies in laser group 1 and laser group 2 showed significantly better circularity than the manual CCCs at 7 days (P<.001). There was a significant correlation between the intended versus achieved capsulotomy size in the 2 laser groups. Both laser groups had better intraocular lens (IOL) centration than the manual group at all timepoints (P<.001). Between-group differences in uncorrected and corrected distance visual acuities were not statistically significant. The residual spherical equivalent and mean absolute error were statistically significantly smaller in the 2 laser groups than in the manual group (P=.038) and increased significantly over time in all the groups (P<.001). CONCLUSIONS: Femtosecond laser capsulotomies showed better circularity with more predictable size than manual CCCs. In addition, IOL centration was better immediately after surgery and over time with better refractive results in the 2 laser groups.
引用
收藏
页码:2035 / 2043
页数:9
相关论文
共 30 条
[1]  
[Anonymous], 1999, HOLL IOL CONS US GUI
[2]   THE LENS OPACITIES CLASSIFICATION SYSTEM-III [J].
CHYLACK, LT ;
WOLFE, JK ;
SINGER, DM ;
LESKE, MC ;
BULLIMORE, MA ;
BAILEY, IL ;
FRIEND, J ;
MCCARTHY, D ;
WU, SY .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :831-836
[3]   Comparison of IOL Power Calculation and Refractive Outcome After Laser Refractive Cataract Surgery With a Femtosecond Laser Versus Conventional Phacoemulsification [J].
Filkom, Tamas ;
Kovacs, Illes ;
Takacs, Agnes ;
Horvath, Eva ;
Knorz, Michael C. ;
Nagy, Zoltan Z. .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (08) :540-544
[4]   Femtosecond laser capsulotomy [J].
Friedman, Neil J. ;
Palanker, Daniel V. ;
Schuele, Georg ;
Andersen, Dan ;
Marcellino, George ;
Seibel, Barry S. ;
Battle, Juan ;
Feliz, Rafael ;
Talamo, Jonathan H. ;
Blumenkranz, Mark S. ;
Culbertson, William W. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (07) :1189-1198
[5]   CONTINUOUS CURVILINEAR CAPSULORHEXIS [J].
GIMBEL, HV ;
NEUHANN, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (01) :110-111
[6]  
Gonzalez R.C., 2009, DIGITAL IMAGE PROCES, DOI 10.1117/1.3115362
[7]   Comparison of decentration and tilt between one piece and three piece polymethyl methacrylate intraocular lenses [J].
Hayashi, K ;
Hayashi, H ;
Nakao, F ;
Hayashi, F .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (04) :419-422
[8]   Femtosecond laser-assisted cataract surgery [J].
He, Lingmin ;
Sheehy, Katrina ;
Culbertson, William .
CURRENT OPINION IN OPHTHALMOLOGY, 2011, 22 (01) :43-52
[9]  
KORYNTA J, 1994, J REFRACT CORNEAL S, V10, P556
[10]   Intraocular Lens Tilt and Decentration Measured By Scheimpflug Camera Following Manual or Femtosecond Laser-created Continuous Circular Capsulotomy [J].
Kranitz, Kinga ;
Mihaltz, Kata ;
Sandor, Gabor L. ;
Takacs, Agnes ;
Knorz, Michael C. ;
Nagy, Zoltan Z. .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (04) :259-263