An improved high performance liquid chromatography-fluorescence detection method for the analysis of major phenolic compounds in cigarette smoke and smokeless tobacco products

被引:16
作者
Wu, Jingcun [1 ]
Rickert, William S. [1 ]
Masters, Andrew [1 ]
机构
[1] Labstat Int ULC, Kitchener, ON N2C 1L3, Canada
关键词
Improved HPLC method; Fluorescence detection; Cigarette smoke; Tobacco; Smokeless tobacco; Phenols; PRESSURE CHEMICAL-IONIZATION; MASS-SPECTROMETRY; WATER SAMPLES; EXTRACTION; CLASSIFICATION;
D O I
10.1016/j.chroma.2012.09.060
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An improved HPLC method has been developed for the determination of major phenolic compounds in cigarette smoke. A novel reversed phase column with a pentafluorophenylpropyl (PFP) ligand in the stationary phase was chosen to separate the positional isomers (p-, m-, and o-cresols). Methanol instead of acetonitrile was used as the organic mobile phase component to improve the separation of the isomers and cope with the crisis of global acetonitrile shortage in 2009. A shorter analytical column with smaller particle size was used to further increase separation efficiency and reduces solvent consumption. These improvements have led to a new HPLC method that is simpler and faster than the GC-MS method and more sensitive, selective and efficient than the widely used traditional HPLC method. The limit of detection (LOD) and limit of quantification (LOQ) of this method are at the ng/mL level for most of the phenols with good linearity (R-2 >= 0.999) and precision (RSD < 15%). The method has been validated using reference tobacco products. The mainstream and sidestream cigarette smoke yields of phenolic compounds obtained by this method are comparable to those obtained by traditional HPLC method with the advantage that p-, m-, and o-cresols can be determined and reported separately by the new method. The method can also be applied for analysis of phenols in smokeless tobacco product. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:40 / 47
页数:8
相关论文
共 22 条
[1]   Determination of priority phenolic compounds in soil samples by various extraction methods followed by liquid chromatography atmospheric pressure chemical ionisation mass spectrometry [J].
Alonso, MC ;
Puig, D ;
Silgoner, I ;
Graserbauer, M ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 1998, 823 (1-2) :231-239
[2]   Contributions to reversed-phase column selectivity. I. Steric interaction [J].
Carr, P. W. ;
Dolan, J. W. ;
Neue, U. D. ;
Snyder, L. R. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (13) :1724-1742
[3]   Chromatographic classification and comparison of commercially available reversed-phase liquid chromatographic columns containing phenyl moieties using principal component analysis [J].
Euerby, Melvin R. ;
Petersson, Patrik ;
Campbell, William ;
Roe, Wendy .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) :138-151
[4]   Chromatographic classification and comparison of commercially available perfluorinated stationary phases for reversed-phase liquid chromatography using Principal Component Analysis [J].
Euerby, MR ;
McKeown, AP ;
Petersson, P .
JOURNAL OF SEPARATION SCIENCE, 2003, 26 (3-4) :295-306
[5]   Column selectivity in reversed-phase liquid chromatography - VIII. Phenylalkyl and fluoro-substituted columns [J].
Marchand, DH ;
Croes, K ;
Dolan, JW ;
Snyder, LR ;
Henry, RA ;
Kallury, KMR ;
Waite, S ;
Carr, PW .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1062 (01) :65-78
[6]   Gas chromatography/mass spectrometry versus liquid chromatography/fluorescence detection in the analysis of phenols in mainstream cigarette smoke [J].
Moldoveanu, Serban C. ;
Kiser, Melissa .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1141 (01) :90-97
[7]   Extraction and analysis of phenolics in food [J].
Naczk, M ;
Shahidi, F .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1054 (1-2) :95-111
[8]   SEPARATION AND QUANTITATION OF PHENOLIC-COMPOUNDS IN MAINSTREAM CIGARETTE-SMOKE BY CAPILLARY GAS-CHROMATOGRAPHY WITH MASS-SPECTROMETRY IN THE SELECTED-ION MODE [J].
NANNI, EJ ;
LOVETTE, ME ;
HICKS, RD ;
FOWLER, KW ;
BORGERDING, MF .
JOURNAL OF CHROMATOGRAPHY, 1990, 505 (02) :365-374
[9]  
Puig D, 1996, J MASS SPECTROM, V31, P1297, DOI 10.1002/(SICI)1096-9888(199611)31:11<1297::AID-JMS425>3.3.CO
[10]  
2-C