Real-Time Robust Heart Rate Estimation From Wrist-Type PPG Signals Using Multiple Reference Adaptive Noise Cancellation

被引:71
作者
Chowdhury, Sayeed Shafayet [1 ]
Hyder, Rakib [1 ]
Bin Hafiz, Md. Samzid [1 ]
Haque, Mohammad Ariful [1 ]
机构
[1] Bangladesh Univ Engn & Technol, Dept Elect & Elect Engn, Dhaka 1205, Bangladesh
关键词
Adaptive noise cancellation (ANC); heart rate (HR) monitoring; motion artifact (MA); periodogram; photoplethysmography (PPG); recursive least-squares (RLS) adaptive filter; MOTION ARTIFACT; PHOTOPLETHYSMOGRAPHY; REDUCTION; ACCELEROMETERS; SENSOR; FILTER;
D O I
10.1109/JBHI.2016.2632201
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Heart rate (HR) monitoring using photo-plethysmographic (PPG) signals recorded from wearers' wrist greatly facilitates design of wearable devices and maximizes user experience. However, placing PPG sensors in wrist causes much stronger and complicated motion artifacts (MA) due to loose interface between sensors and skin. Therefore, developing robust HR estimation algorithms for wrist-type PPG signals has significant commercial values. In this paper, we propose a robust HR estimation algorithm for wrist-type PPG signals using multiple reference adaptive noise cancellation (ANC) technique-termed here as "MURAD." The main challenge of using ANC for MA reduction is to devise a qualified reference noise signal (RNS) to the adaptive filter. We propose a novel solution by using four RNSs, namely, the three-axis accelerometer data and the difference signal between the two PPG signals. For each RNS, we get a different version of the cleaned PPG signal. Then, a set of probable HR values is estimated using all of the cleaned PPG signals, and then, the value that is closest to the estimated HR of the previous time window is chosen to be the HR estimate of the current window. Then, some peak verification techniques are employed to ensure accurate HR estimations. The proposed technique gives lower average absolute error compared to state-of-the art methods. So, MURAD method provides a promising solution to the challenge of HR monitoring using PPG in wearable devices during severe MA conditions.
引用
收藏
页码:450 / 459
页数:10
相关论文
共 34 条
[1]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[2]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[3]  
Asada HH, 2004, P ANN INT IEEE EMBS, V26, P2157
[4]  
Fukushima H, 2012, IEEE ENG MED BIO, P2901, DOI 10.1109/EMBC.2012.6346570
[5]   A new method for pulse oximetry possessing inherent insensitivity to artifact [J].
Hayes, MJ ;
Smith, PR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (04) :452-461
[6]   A new probe for ankle systolic pressure measurement using Photoplethysmography (PPG) [J].
Jönsson, R ;
Laurent, C ;
Skau, T ;
Lindberg, LG .
ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (02) :232-239
[7]   SKIN PHOTOPLETHYSMOGRAPHY - A REVIEW [J].
KAMAL, AAR ;
HARNESS, JB ;
IRVING, G ;
MEARNS, AJ .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1989, 28 (04) :257-269
[8]   Motion artifact reduction in photoplethysmography using independent component analysis [J].
Kim, BS ;
Yoo, SK .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (03) :566-568
[9]   Adaptive noise cancellation using accelerometers for the PPG signal from forehead [J].
Kim, Sang Hyun ;
Ryoo, Dong Wan ;
Bae, Changseok .
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, :2564-+
[10]   Two-Stage Approach for Detection and Reduction of Motion Artifacts in Photoplethysmographic Data [J].
Krishnan, Rajet ;
Natarajan, Balasubramaniam ;
Warren, Steve .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (08) :1867-1876