Accuracy and Precision of Two Computer-Assisted Methods of Radiographic Wear Measurement in Total Hip Arthroplasty

被引:13
|
作者
Crockarell, John R., Jr. [1 ]
Snearly, Christine M. [2 ]
机构
[1] Univ Tennessee, Campbell Clin, Dept Orthopaed Surg, Collierville, TN 38017 USA
[2] InMot Orthopaed Res Ctr, Memphis, TN USA
关键词
Hip Analysis Suite; Roentgen Monographic Analysis Tool; total hip arthroplasty; MEASURING POLYETHYLENE WEAR;
D O I
10.1016/j.arth.2011.04.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Roentgen Monographic Analysis Tool (ROMAN) and Hip Analysis Suite (HAS) were used to analyze radiographs of a phantom hip model. Displacements of known magnitude and direction were produced using dial micrometers. Differences between the known displacement and the programs reported displacement were compared. Hip Analysis Suite was superior with a median error of 0.075 mm (range, 0.019-0.205 mm) compared with 0.137 mm (range, 0.008-0.389 mm) for ROMAN (P = .002). Hip Analysis Suite was also more precise when evaluating intraobserver variability, with a standard deviation between radiographs of 0.007 mm (range, 0.002-0.009 mm), whereas ROMAN's standard deviation was 0.117 mm (range, 0.007-0.153 mm). Repeatability for HAS was 0.019 mm and 0.325 mm for ROMAN. Hip Analysis Suite was more accurate and precise than ROMAN under experimental conditions with digital radiographs.
引用
收藏
页码:37 / 40
页数:4
相关论文
共 50 条
  • [1] Computer-assisted osteodensitometry following total hip arthroplasty
    Reilly, Keryn
    Munro, Jacob
    Pitto, Rocco P.
    EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (06) : 763 - 768
  • [2] Direct Anatomic Registration in Computer-Assisted Total Hip Arthroplasty Improves Accuracy of Acetabular Cup Alignment
    Patamarat, Apisit
    Laoruengthana, Artit
    Kitcharanant, Nitchanant
    Khantasit, Jakkaphong
    Thremthakanpon, Witoon
    ARTHROPLASTY TODAY, 2023, 21
  • [3] Accuracy of Acetabular Component Positioning Using Computer-assisted Navigation in Direct Anterior Total Hip Arthroplasty
    Bradley, Michael P.
    Benson, Jessica R.
    Muir, Jeffrey M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (04)
  • [5] Total hip arthroplasty in osteopetrosis using computer-assisted fluoroscopic navigation
    Egawa, H
    Nakano, S
    Hamada, D
    Sato, R
    Yasui, N
    JOURNAL OF ARTHROPLASTY, 2005, 20 (08) : 1074 - 1077
  • [6] Evaluation of cup placement accuracy in computer assisted total hip arthroplasty
    Kaneta, Hiroki
    Shoji, Takeshi
    Ueki, Shinichi
    Morita, Hiroyuki
    Kozuma, Yosuke
    Adachi, Nobuo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2025, 145 (01)
  • [7] Computer-Assisted Total Hip Arthroplasty Improves Acetabular Prosthesis Placement Accuracy: A Multicenter, Randomized Controlled Clinical Study
    Zhou, Ge
    Geng, Xiao
    Zhang, Ming
    Sun, Zhiwen
    Li, Feng
    Zhao, Minwei
    Tian, Hua
    ORTHOPAEDIC SURGERY, 2024, 16 (12) : 3078 - 3087
  • [8] Computer-assisted navigation as a diagnostic tool in revision total hip arthroplasty: A case report
    Paprosky, Wayne G.
    Vincent, John
    Sostak, Jennifer R.
    Muir, Jeffrey M.
    SAGE OPEN MEDICAL CASE REPORTS, 2019, 7
  • [9] Total hip arthroplasty through a minimal posterior approach using imageless computer-assisted hip navigation
    Wixson, RL
    MacDonald, MA
    JOURNAL OF ARTHROPLASTY, 2005, 20 (07) : 51 - 56
  • [10] Accuracy of Computer-Navigated Total Hip Arthroplasty
    Snyder, Garrett M.
    Calderon, Santiago A. Lozano
    Lucas, Paul A.
    Russinoll, Scott
    JOURNAL OF ARTHROPLASTY, 2012, 27 (03) : 415 - 420