TOWARDS DOSE REDUCTION IN CT: PATIENT RADIATION DOSE ASSESSMENT FOR CT EXAMINATIONS AT UNIVERSITY HEALTH CENTER IN CANADA AND COMPARISON WITH NATIONAL DIAGNOSTIC REFERENCE LEVELS

被引:24
作者
Heliou, Regis [1 ]
Normandeau, Lysanne [1 ]
Beaudoin, Gilles [1 ]
机构
[1] Univ Montreal, Hop Notre Dame, Ctr Hosp, Montreal, PQ, Canada
关键词
COMPUTED-TOMOGRAPHY; STRATEGIES;
D O I
10.1093/rpd/ncr024
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Dose indicators such as the computed tomography dose index (CTDI) and dose-length product (DLP) were gathered for all routine abdomen-pelvis, chest and head examinations performed on all computed tomography (CT) scanners at a University Health Center (UHC) in Canada. These indicators were analysed and compared with the range of diagnostic reference levels (DRLs) suggested by Health Canada and with DRLs in other countries. Mean DLP values varied from one scanner to another, but mean values at the UHC (750 mGy cm(-1) for abdomen-pelvis CT, 349 mGy cm(-1) for chest CT and 1181 mGy cm(-1) for head CT) were all below the upper limit of the range of DRLs suggested by Health Canada. Local DRLs at the UHC were set to 810 mGy cm(-1) for abdomen-pelvis CT, 345 mGy cm(-1) for chest CT and 1205 mGy cm(-1) for head CT. Results, however, show the need for protocols revisions, since some scanners exhibit mean DLP values slightly below or above the upper limit of the range of DRLs suggested by Health Canada.
引用
收藏
页码:202 / 210
页数:9
相关论文
共 32 条
  • [1] Aldrich JE, 2005, CAN ASSOC RADIOL J, V56, P94
  • [2] Aldrich JE, 2006, CAN ASSOC RADIOL J, V57, P79
  • [3] [Anonymous], 2009, 160 NCRP
  • [4] [Anonymous], 2001, ANN ICRP
  • [5] [Anonymous], 1991, ANN ICRP, V60
  • [6] Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital
    Donnelly, LF
    Emery, KH
    Brody, AS
    Laor, T
    Gylys-Morin, VM
    Anton, CG
    Thomas, SR
    Frush, DP
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 303 - 306
  • [7] European Commission Guidance on Diagnostic Reference Levels for Medical Exposures, 1999, GUID DIAGN REF LEV M
  • [8] Friberg E G, 2008, NATL COLLECTION LOCA
  • [9] ICRP-International Commission on Radiological Protection, 2007, ANN ICRP, V37
  • [10] International Commission on Radiological Protection, 1996, ANN ICRP, V72