Measurement of the Limbus-Insertion Distance in Adult Strabismus Patients with Anterior Segment Optical Coherence Tomography

被引:45
作者
Liu, Xiaoqiang [1 ]
Wang, Fang [1 ]
Xiao, Ying [1 ,2 ]
Ye, Xinhai [1 ]
Hou, Lijie [2 ]
机构
[1] Tongji Univ, Sch Med, Dept Ophthalmol, Shanghai Peoples Hosp 10, Shanghai 200072, Peoples R China
[2] Wenzhou Med Coll, Hosp Eye, Wenzhou, Peoples R China
关键词
ULTRASOUND BIOMICROSCOPY; ORBITAL STRUCTURES; RECTUS; ESOTROPIA; MUSCLES; SITE;
D O I
10.1167/iovs.11-7752
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To determine the ability of the anterior segment optical coherence tomography (AS-OCT) in measuring the distance from the corneoscleral limbus to the insertion site of the horizontal extraocular muscles in adult patients with strabismus. METHODS. A total of 16 strabismus patients were recruited for this study. The limbus-insertion distances of the horizontal rectus muscles were measured with AS-OCT preoperatively and calipers intraoperatively. The intraclass correlation coefficient (ICC), Pearson's correlation coefficients, and Bland-Altman plots were used to evaluate the degree of agreement between the two methods of measurements. RESULTS. Measurements of the limbus-insertion distances were taken on 37 muscles of the 16 patients: 18 medial rectus (MR) and 19 lateral rectus (LR). The mean limbus-insertion distance of MR and LR measured intraoperatively were 5.32 +/- 0.44 mm (range, 4.5-6.1 mm) and 6.58 +/- 0.53 mm (range, 5.5-7.5 mm). Comparable results measured with the AS-OCT were 5.72 +/- 0.60 mm (range, 4.62-6.82 mm) and 6.80 +/- 0.61 mm (range, 5.8-7.86 mm). For MR group and LR group, the values of limbus-insertion distance showed high Pearson's correlation coefficients (0.729 and 0.786, respectively). With the ICC analysis excellent agreement was observed for the measurements of LR group (ICC = 0.75). Fair to good agreement was observed for the MR group (ICC = 0.61). Bland-Altman plots also showed good agreement between the two methods of measurements. CONCLUSIONS. AS-OCT can image the structure of horizontal rectus muscles well and provide good reliability and accuracy in measurement of the limbus-insertion distance. (Invest Ophthalmol Vis Sci. 2011;52:8370-8373) DOI: 10.1167/iovs.117752
引用
收藏
页码:8370 / 8373
页数:4
相关论文
共 23 条
[1]  
APT L, 1982, OPHTHALMIC SURG LAS, V13, P108
[2]  
BARSOUMHOMSY M, 1981, CAN J OPHTHALMOL, V16, P181
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Ultrasound biomicroscopy in strabismus reoperations [J].
Dai, Shuan ;
Kraft, Stephen P. ;
Smith, David R. ;
Buncic, J. Raymond .
JOURNAL OF AAPOS, 2006, 10 (03) :202-205
[5]   High-resolution magnetic resonance imaging of the normal extraocular musculature [J].
Ettl, A ;
Kramer, J ;
Daxer, A ;
Koornneef, L .
EYE, 1997, 11 (6) :793-797
[6]  
Huang David, 2004, Ophthalmol Clin North Am, V17, P1, DOI 10.1016/S0896-1549(03)00103-2
[7]   THE MEDIAL RECTUS MUSCLE INSERTION SITE IN INFANTILE ESOTROPIA [J].
KEECH, RV ;
SCOTT, WE ;
BAKER, JD .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 109 (01) :79-84
[8]  
Kushner B J, 1987, J Pediatr Ophthalmol Strabismus, V24, P159
[9]  
McGraw KO, 1996, PSYCHOL METHODS, V1, P30, DOI 10.1037/1082-989X.1.4.390
[10]  
NAKAMURA T, 1991, Nippon Ganka Gakkai Zasshi, V95, P698