Factors associated with temporal window failure in transcranial Doppler sonography

被引:14
作者
Lee, Chan-Hyuk [1 ]
Jeon, Seung-Ho [1 ]
Wang, Su-Jung [1 ]
Shin, Byoung-Soo [1 ,2 ]
Kang, Hyun Goo [1 ,2 ]
机构
[1] Jeonbuk Natl Univ Hosp, Dept Neurol, Jeonju, South Korea
[2] Jeonbuk Natl Univ, Jeonbuk Natl Univ Hosp, Dept Neurol, Res Inst Clin Med,Biomed Res Inst, 20 Geonji Ro, Jeonju 54907, South Korea
关键词
Cerebral blood flow; Risk factor; Soft tissue; Temporal bone; Transcranial Doppler; BONE WINDOW; ACOUSTIC WINDOW; IMAGE QUALITY; THICKNESS; INSUFFICIENT; POPULATION; ULTRASOUND; LIMITS;
D O I
10.1007/s10072-020-04459-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Temporal window failure (TWF) is found in 8-20% of subjects. There are still insufficient studies about the factors affecting TWF. We aimed to elucidate the underlying causes of TWF. Methods We analyzed 376 patients who underwent both transcranial Doppler sonography and cerebral angiographic imaging. They were divided into two groups: with and without TWF. Demographics, cardiovascular factors, degree of stenosis from the proximal intracranial artery to the middle cerebral artery (MCA), MCA diameter, and skull features were examined. Results The subjects were 314 TWF-negative patients and 62 TWF-positive patients. The TWF-negative group was younger than that of the TWF-positive group (67.0 +/- 12.1 vs. 75.2 +/- 9.4, p < 0.001). The proportion of men in the TWF-negative group was higher than in the TWF-positive group (71% vs. 29%; p < 0.001). The TWF-negative group had a higher smoking rate than the TWF-positive group (34.4% vs. 12.9%; p = 0.001). In multivariate logistic regression analysis, age (odds ratio (OR), 1.05; p = 0.019), sex (OR, 4.64; p = 0.002), temporal bone thickness (OR, 6.03; p < 0.001), temporal bone density (OR, 0.996; p = 0.002), and soft tissue thickness (OR, 1.31; p = 0.004) significantly affected TWF. Conclusions In addition to age, sex, temporal bone thickness, and temporal bone density which were previously reported as variables associated with TWF, we confirmed that soft tissue thickness of the temporal area is a new associated factor of TWF. Measuring soft tissue thickness of the temporal area for patients with suspected TWF could be useful in identifying measurement error due to technical problems.
引用
收藏
页码:3293 / 3299
页数:7
相关论文
共 18 条
  • [1] EVALUATION OF THE TEMPORAL ACOUSTIC WINDOW FOR TRANSCRANIAL DOPPLER IN A MULTI-ETHNIC POPULATION IN BRAZIL
    Bazan, Rodrigo
    Braga, Gabriel Pereira
    Luvizutto, Gustavo Jose
    Hueb, Joao Carlos
    Hokama, Newton Key
    Zanati Bazan, Silmeia Garcia
    de Carvalho Nunes, Helio Rubens
    Leite, Joao Pereira
    Pontes-Neto, Octavio Marques
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (08) : 2131 - 2134
  • [2] Transcranial Doppler in a Hispanic-Mestizo population with neurological diseases: a study of sonographic window and its determinants
    Brunser, Alejandro M.
    Silva, Claudio
    Carcamo, Daniel
    Munoz, Paula
    Hoppe, Arnold
    Olavarria, Veronica V.
    Diaz, Violeta
    Abarca, Juan
    [J]. BRAIN AND BEHAVIOR, 2012, 2 (03): : 231 - 236
  • [3] The thickness of the temporal squama and its implication for transcranial sonography
    Jarquin-Valdivia, AA
    McCartney, J
    Palestrant, D
    Johnston, SC
    Gress, D
    [J]. JOURNAL OF NEUROIMAGING, 2004, 14 (02) : 139 - 142
  • [4] Image quality of the temporal bone window examined by transcranial Doppler sonography and correlation with postmortem computed tomography measurements
    Kollár, J
    Schulte-Altedorneburg, G
    Sikula, J
    Fülesdi, B
    Ringelstein, EB
    Mehta, V
    Csiba, L
    Droste, DW
    [J]. CEREBROVASCULAR DISEASES, 2004, 17 (01) : 61 - 65
  • [5] Suitability of temporal bone acoustic window: Conventional TCD versus transcranial color-coded duplex sonography
    Krejza, Jaroslaw
    Swiat, Maciej
    Pawlak, Mikolaj A.
    Oszkinis, Grzegorz
    Weigele, John
    Hurst, Robert W.
    Kasner, Scott
    [J]. JOURNAL OF NEUROIMAGING, 2007, 17 (04) : 311 - 314
  • [6] The thickness and texture of temporal bone in brain CT predict acoustic window failure of transcranial Doppler
    Kwon, Jee-Hyun
    Kim, Jong S.
    Kang, Dong-Wha
    Bae, Kyun-Seop
    Kwon, Sun U.
    [J]. JOURNAL OF NEUROIMAGING, 2006, 16 (04) : 347 - 352
  • [7] Echographic measurement of skin thickness in adults by high frequency ultrasound to assess the appropriate microneedle length for intradermal delivery of vaccines
    Laurent, Aurelie
    Mistretta, Frederic
    Bottigioli, David
    Dahel, Karima
    Goujon, Catherine
    Nicolas, Jean Francois
    Hennino, Anca
    Laurent, Philippe E.
    [J]. VACCINE, 2007, 25 (34) : 6423 - 6430
  • [8] Factors Associated with No or Insufficient Temporal Bone Window Using Transcranial Color-coded Sonography
    Lin, Yi-Pin
    Fu, Mu-Hui
    Tan, Teng-Yeow
    [J]. JOURNAL OF MEDICAL ULTRASOUND, 2015, 23 (03) : 129 - 132
  • [9] SIMULTANEOUS BILATERAL REAL-TIME 3-D TRANSCRANIAL ULTRASOUND IMAGING AT 1 MHZ THROUGH POOR ACOUSTIC WINDOWS
    Lindsey, Brooks D.
    Nicoletto, Heather A.
    Bennett, Ellen R.
    Laskowitz, Daniel T.
    Smith, Stephen W.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (04) : 721 - 734
  • [10] Technical limits in transcranial Doppler recording: Inadequate acoustic windows
    Marinoni, M
    Ginanneschi, A
    Forleo, P
    Amaducci, L
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (08) : 1275 - 1277