Design, simulation and performance analysis of MEMS based bio-sensors for the detection of cholera and diarrhea

被引:4
作者
Vineetha, K. V. [1 ]
Sravani, K. Girija [1 ,2 ]
Sailaja, B. V. S. [1 ]
Guha, Koushik [2 ]
Varma, P. Srinivas [1 ]
Rao, K. Srinivasa [1 ]
机构
[1] Koneru Laskmaiah Educ Fdn Deemed Be Univ, Dept Elect & Commun Engn, MEMS Res Ctr, Vaddeswaram, Andhra Pradesh, India
[2] Natl Inst Technol, Dept ECE, Natl MEMS Design Ctr, Silchar, Assam, India
来源
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS | 2018年 / 24卷 / 12期
关键词
MICROCANTILEVER; STRESS;
D O I
10.1007/s00542-018-3880-8
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents three types of the microchannel which is used for the detection of cholera and diarrhea. The three types of microchannels are namely cylindrical, rectangular, and triangular. The microchannels are designed and simulated using FEM tool. Capacitance, flow rate, flow velocity analysis are also carried out using FEM tool. The performance analysis of three channels are carried out using FEM tool. The principle used for the detection of cholera and diarrhea is a capacitive technique which have high sensitivity. The cylindrical channel has high performance than the rectangle and triangle based channel The time take by the cylindrical channel is the order of (6, 9 min) which is very less time for the detection than the rectangle (8, 13 min) and triangle (10, 15 min) based channels. The sensitivity and accuracy for the cylindrical channel is high than the rectangle and triangle based channels. Cylindrical channel have high performance than the rectangle and triangle based microchannels.
引用
收藏
页码:4785 / 4797
页数:13
相关论文
共 26 条
  • [21] Design and simulation of diatom-based microcantilever immunobiosensor for the early detection of Karnal bunt
    Manjita Mishra
    Shailendra Kumar Singh
    Rama Shanker
    Shanthy Sundaram
    3 Biotech, 2020, 10
  • [22] Performance Analysis of Optical MEMS Based Pressure Sensor Using Ring Resonators Structure on Circular Diaphragm
    Upadhyaya, Anup M.
    Srivastava, Maneesh
    Sharan, Preeta
    Srinivas, T.
    PROCEEDINGS OF THE 2019 IEEE REGION 10 CONFERENCE (TENCON 2019): TECHNOLOGY, KNOWLEDGE, AND SOCIETY, 2019, : 668 - 672
  • [23] Sealing Performance Analysis of Natural Gas Pipeline Venting and Nitrogen Injection Device Based on Numerical Simulation and Experiment
    Chen, Yong
    Huang, Xin
    Tan, Jinjin
    Meng, Dongying
    Tian, Shuxian
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2023, 23 (03) : 1171 - 1184
  • [24] Factor analysis and numerical simulation of rock breaking efficiency of TBM deep rock mass based on orthogonal design
    Li Xiao-jing
    Zhang Hua-ken
    Bai Yi-fan
    Zhang Xiang-yang
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2022, 29 (04) : 1345 - 1362
  • [25] Design and Analysis of a Slotted Micro-cantilever based Biosensor for Detection of P24 Antigen in HIV Diagnoses
    Sarker, Tasnim
    Samad, Mst Fateha
    2020 IEEE REGION 10 SYMPOSIUM (TENSYMP) - TECHNOLOGY FOR IMPACTFUL SUSTAINABLE DEVELOPMENT, 2020, : 1400 - 1403
  • [26] Design of Test Method for Analysis and Estimation of LED Luminaire Lifetime Performance Under Cycle Based Realistic Operating Conditions
    Padmasali, Anjan N.
    Lokesh, J.
    Kini, Savitha G.
    IEEE ACCESS, 2024, 12 : 87944 - 87953