Swallowing assessment in patients with dysphagia: Validity and reliability of a pocket-sized ultrasound system

被引:10
作者
Winiker, Katharina [1 ,2 ,3 ]
Hammond, Rebecca [1 ,2 ,4 ]
Thomas, Paige [1 ,2 ,4 ]
Dimmock, Alice [4 ]
Huckabee, Maggie-Lee [1 ,2 ]
机构
[1] Univ Canterbury, Dept Psychol Speech & Hearing, Christchurch, New Zealand
[2] Univ Canterbury, Rose Ctr Stroke Recovery & Res, Christchurch, New Zealand
[3] Swiss Univ Speech & Language Sci SHLR, Dept Res & Dev, Rorschach, Switzerland
[4] Waitemat Dist Hlth Board, Speech Language Therapy, Auckland, New Zealand
关键词
ultrasound; videofluoroscopy; deglutition; dysphagia; validity; reliability; ULTRASONOGRAPHY; DISPLACEMENT;
D O I
10.1111/1460-6984.12703
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Background The use of ultrasound as an adjunct to clinical swallowing evaluation provides quantitative physiological and morphological data. As a low-risk procedure, ultrasound imaging can be performed outside of a medical setting. This is particularly important for patients living in rural areas with restricted access to a hospital. Technical advances have produced pocket-sized ultrasound technology that is more affordable, and therefore within the fiscal reach of most allied health services. Aims To explore the validity and reliability of pocket-sized ultrasound technology in dysphagia assessment. Methods & Procedures Data were acquired from 43 patients with dysphagia using the Clarius ultrasound device. Ultrasound and videofluoroscopic measures of hyoid and laryngeal displacement during liquid and puree swallowing were collected concurrently to quantify correlation and agreement between identical measures derived from the two instruments. Reliability of ultrasound was assessed for measures of hyoid and laryngeal displacement, tongue thickness, and size of the submental muscles in eight patients. Reliability was evaluated for the entire process of data acquisition including scanning and online measurement using an iPad in a clinical setting and for offline measurement on a computer screen to explore environmental influences on reliability. Outcomes & Results Results revealed poor correlation between the measures of interest across instruments. Reliability of the entire process of data acquisition in a clinical setting was insufficient while reliability was more promising for offline measurements. Conclusions & Implications The clinical use of pocket-sized ultrasound devices, such as the Clarius system, for swallowing evaluation is not indicated at this time. Enhanced validity and reliability of the entire process of data acquisition are needed prior to clinical translation of such technology. WHAT THIS PAPER ADDS What is already known on the subject The use of ultrasound allows for radiation-free, non-invasive swallowing assessment. Some data suggest that ultrasound is valid and reliable in the evaluation of swallowing using standard-sized equipment. Insufficient validity and reliability have been reported for pocket-sized ultrasound technology in the assessment of healthy swallowing. What this paper adds to existing knowledge This research is the first to provide validity and reliability data of the pocket-sized Clarius technology in the evaluation of swallowing in patients with dysphagia. Insufficient validity and reliability of online data acquisition in a clinical environment were found. Reliability for offline measurement was more promising. What are the potential or actual clinical implications of this work? The clinical use of pocket-sized ultrasound devices, such as the Clarius system, for swallowing assessment is not indicated at this time.
引用
收藏
页码:539 / 551
页数:13
相关论文
共 21 条
  • [1] Allen Mike., 2017, SAGE ENCY COMMUNICAT, DOI [10.4135/9781483381411, DOI 10.4135/9781483381411]
  • [2] Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables
    Bartlett, J. W.
    Frost, C.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (04) : 466 - 475
  • [3] Fitting Linear Mixed-Effects Models Using lme4
    Bates, Douglas
    Maechler, Martin
    Bolker, Benjamin M.
    Walker, Steven C.
    [J]. JOURNAL OF STATISTICAL SOFTWARE, 2015, 67 (01): : 1 - 48
  • [4] Chen YC, 2017, J MED ULTRASOUND, V25, P90, DOI 10.1016/j.jmu.2017.01.002
  • [5] Daniels S.K., 2014, DYSPHAGIA FOLLOWING
  • [6] Aging-Related Geniohyoid Muscle Atrophy Is Related to Aspiration Status in Healthy Older Adults
    Feng, Xin
    Todd, Tee
    Lintzenich, Catherine R.
    Ding, Jingzhong
    Carr, Jeffery J.
    Ge, Yaorong
    Browne, James D.
    Kritchevsky, Stephen B.
    Butler, Susan G.
    [J]. JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2013, 68 (07): : 853 - 860
  • [7] APPLICATION OF ULTRASONOGRAPHY IN ASSESSING OROPHARYNGEAL DYSPHAGIA IN STROKE PATIENTS
    Hsiao, Ming-Yen
    Chang, Yeun-Chung
    Chen, Wen-Shiang
    Chang, Hui-Ya
    Wang, Tyng-Guey
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (09) : 1522 - 1528
  • [8] ULTRASONOGRAPHIC EVALUATION OF HYOID-LARYNX APPROXIMATION IN DYSPHAGIC STROKE PATIENTS
    Huang, Ya-Ling
    Hsieh, Shih-Fu
    Chang, Yeun-Chung
    Chen, Hsiang-Chen
    Wang, Tyng-Guey
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (07) : 1103 - 1108
  • [9] UPPER ESOPHAGEAL SPHINCTER OPENING AND MODULATION DURING SWALLOWING
    JACOB, P
    KAHRILAS, PJ
    LOGEMANN, JA
    SHAH, V
    HA, T
    [J]. GASTROENTEROLOGY, 1989, 97 (06) : 1469 - 1478
  • [10] Structural displacements in normal swallowing:: A videofluoroscopic study
    Leonard, RJ
    Kendall, KA
    McKenzie, S
    Gonçalves, MI
    Walker, A
    [J]. DYSPHAGIA, 2000, 15 (03) : 146 - 152