A novel nanocarrier sirolimus-coated balloon for coronary interventions: 12-Month data from the Nanolute Registry

被引:20
作者
Dani, Sameer [1 ]
Shah, Dinesh [2 ]
Sojitra, Prakash [3 ]
Parikh, Keyur [4 ]
Shetty, Ranjan [5 ]
Di Palma, Gaetano [6 ]
Cortese, Bernardo [7 ,8 ]
机构
[1] Life Care Inst Med Sci, Ahmadabad, Gujarat, India
[2] Beaumont Hosp, Royal Oak, MI USA
[3] Concept Med Private Ltd, Surat, India
[4] Care Inst Med Sci, Ahmadabad, Gujarat, India
[5] Kasturba Med Ctr, Manipal, Karnataka, India
[6] ASST Fatebenefratelli Sacco, Intervent Cardiol, Milan, Italy
[7] Fdn Monasterio Reg Toscana CNR, Massa, Italy
[8] San Carlo Clin, Intervent Cardiol, Milan, Italy
关键词
SCB; CAD; PTCA; DRUG; RESTENOSIS; RELEASE;
D O I
10.1016/j.carrev.2018.06.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of the Nanolute registry was to observe the clinical performance of a novel sirolimus coated balloon (SCB) (Concept Medical Research Private Limited, India) for the treatment of coronary de-novo and restenotic lesions. Methods: All patients treated with SCB between July 2012 and September 2015 were enrolled at Indian centres and clinically followed for 1, 3, 6 and 12 months post-procedure. Primary endpoints were procedural success and device-oriented adverse cardiac events (DOCE) at 12 months. DOCE were defined as a composite of cardiac death, target lesion revascularization (TLR) and target vessel-myocardial infarction. Results: A total of 394 SCB were used in 332 patients to treat 356 lesions. In-stent restenosis and small coronary vessel disease occurred in 46% and 43% of the patients respectively. Mean balloon length and diameter (average +/- SD) were 21.83 +/- 6.70 mm and 2.69 +/- 0.45 mm respectively. All patients with 1 year follow-up were included. Overall DOCE rate was 4.2% (n = 14) which included death 0.3% (n = 1), TLR 3.6% (n = 12) and myocardial infarction 0.3% (n = 1). Conclusion: The Nanolute prospective registry, is the first clinical evidence of the safety and feasibility of this type of SCB, both in patients with in-stent restenosis or de novo lesions. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:235 / 240
页数:6
相关论文
共 14 条
[1]  
Cortese B, 2017, CARDIOVASC REVASCULA, V18, P487, DOI 10.1016/j.carrev.2017.03.025
[2]   Drug-coated balloon treatment for lower extremity vascular disease intervention: an international positioning document [J].
Cortese, Bernardo ;
Granada, Juan F. ;
Scheller, Bruno ;
Schneider, Peter A. ;
Tepe, Gunnar ;
Scheinert, Dierk ;
Garcia, Lawrence ;
Stabile, Eugenio ;
Alfonso, Fernando ;
Ansel, Gary ;
Zeller, Thomas .
EUROPEAN HEART JOURNAL, 2016, 37 (14) :1096-U100
[3]   SICI-GISE position document on the correct use of the drug release flask in the coronary district [J].
Cortese, Bernardo ;
Sgueglia, Gregory A. ;
Berti, Sergio ;
Biondi-Zoccai, Giuseppe ;
Colombo, Antonio ;
Limbruno, Ugo ;
Bedogni, Francesco ;
Cremonesi, Alberto .
GIORNALE ITALIANO DI CARDIOLOGIA, 2013, 14 (10) :681-689
[4]   Paclitaxel coated balloons for coronary artery interventions: A comprehensive review of preclinical and clinical data [J].
Cortese, Bernardo ;
Bertoletti, Alessandra .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 161 (01) :4-12
[5]   Clinical restenosis after coronary stenting: Perspectives from multicenter clinical trials [J].
Cutlip, DE ;
Chauhan, MS ;
Baim, DS ;
Ho, KKL ;
Popma, JJ ;
Carrozza, JP ;
Cohen, DJ ;
Kuntz, RE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (12) :2082-2089
[6]   Restenosis Delineating the Numerous Causes of Drug-Eluting Stent Restenosis [J].
Farooq, Vasim ;
Gogas, Bill D. ;
Serruys, Patrick W. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (02) :195-205
[7]  
Lemos PA, 2013, EUROINTERVENTION, V9, P148, DOI 10.4244/EIJV9I1A21
[8]   A comparative study of restenosis rates in bare metal and drug-eluting stents [J].
Mohan, Shilpi ;
Dhall, Anil .
INTERNATIONAL JOURNAL OF ANGIOLOGY, 2010, 19 (02) :E66-E72
[9]   REAL-WORLD SAFETY AND OUTCOME MEASURES OF NOVEL SIROLIMUS COATED BALLOON CATHETER [J].
Parikh, Keyur H. ;
Shetty, Ranjan ;
Dani, Sameer ;
Bhatt, Parloop ;
Doshi, Manish ;
Sojitra, Prakash .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) :225-225
[10]  
Sojitra P., 2013, JACC Cardiovasc. Interv, V6, pS40, DOI [10.1016/j.jcin.2013.01.042, DOI 10.1016/J.JCIN.2013.01.042]