Robust Fat Suppression at 3T in High-Resolution Diffusion-Weighted Single-Shot Echo-Planar Imaging of Human Brain

被引:15
作者
Sarlls, Joelle E. [1 ,2 ]
Pierpaoli, Carlo [3 ]
Talagala, S. Lalith [2 ]
Luh, Wen-Ming [4 ]
机构
[1] Natl Inst Neurol Disorders & Stroke, NIH MRI Res Facil, NIH, Bethesda, MD 20892 USA
[2] Uniformed Serv Univ Hlth Sci, Ctr Neurosci & Regenerat Med, Bethesda, MD 20814 USA
[3] Eunice Kennedy Shriver Natl Inst Child Hlth & Hum, Program Pediat Imaging & Tissue Sci, NIH, Bethesda, MD USA
[4] NIMH, Funct MRI Facil, NIH, Bethesda, MD 20892 USA
关键词
mri; diffusion; fat suppression; brain; artifact; SPIN-ECHO; GRADIENT REVERSAL; SLICE-SELECTION; HIGH-FIELD; TENSOR; MRI; EXCITATION; TISSUES;
D O I
10.1002/mrm.22940
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Single-shot echo-planar imaging is the most common acquisition technique for whole-brain diffusion tensor imaging (DTI) studies in vivo. Higher field MRI systems are readily available and advantageous for acquiring DTI due to increased signal. One of the practical issues for DTI with single-shot echo-planar imaging at high-field is incomplete fat suppression resulting in a chemically shifted fat artifact within the brain image. Unsuppressed fat is especially detrimental in DTI because the diffusion coefficient of fat is two orders of magnitude lower than that of parenchyma, producing brighter appearing fat artifacts with greater diffusion weighting. In this work, several fat suppression techniques were tested alone and in combination with the goal of finding a method that provides robust fat suppression and can be used in high-resolution single-shot echo-planar imaging DTI studies. Combination of chemical shift saturation with slice-select gradient reversal within a dual-spin-echo diffusion preparation period was found to provide robust fat suppression at 3 T. Magn Reson Med 66:1658-1665, 2011. (C) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:1658 / 1665
页数:8
相关论文
共 24 条
[11]   Efficient Fat Suppression by Slice-Selection Gradient Reversal in Twice-Refocused Diffusion Encoding [J].
Nagy, Zoltan ;
Weiskopf, Nikolaus .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (05) :1256-1260
[12]  
Pajevic S, 1999, MAGNET RESON MED, V42, P526, DOI 10.1002/(SICI)1522-2594(199909)42:3<526::AID-MRM15>3.0.CO
[13]  
2-J
[14]   Diffusion tensor MR imaging of the human brain [J].
Pierpaoli, C ;
Jezzard, P ;
Basser, PJ ;
Barnett, A ;
DiChiro, G .
RADIOLOGY, 1996, 201 (03) :637-648
[15]  
PIERPAOLI C, 2010, 18 ANN P ISMRM STOCK, P1597
[16]  
PIERPAOLI C, 2009, 17 ANN P ISMRM HON, P1414
[17]  
PIERPAOLI C, 2011, DIFFUSION MRI THEORY
[18]   Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo [J].
Reese, TG ;
Heid, O ;
Weisskoff, RM ;
Wedeen, VJ .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) :177-182
[19]   Improved clinical echo-planar MRI using spatial-spectral excitation [J].
Schick, F ;
Forster, J ;
Machann, J ;
Kuntz, R ;
Claussen, CD .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04) :960-967
[20]   CHEMICAL SHIFT-SPECIFIC SLICE SELECTION - A NEW METHOD FOR CHEMICAL-SHIFT IMAGING AT HIGH MAGNETIC-FIELD [J].
VOLK, A ;
TIFFON, B ;
MISPELTER, J ;
LHOSTE, JM .
JOURNAL OF MAGNETIC RESONANCE, 1987, 71 (01) :168-174