The Use of Superabsorbent Polymers in High Performance Concrete to Mitigate Autogenous Shrinkage in a Large-Scale Demonstrator

被引:20
作者
De Meyst, Laurence [1 ]
Kheir, Judy [1 ,2 ]
Filho, Jose Roberto Tenorio [1 ]
Van Tittelboom, Kim [1 ]
De Belie, Nele [1 ]
机构
[1] Univ Ghent, Magnel Vandepitte Lab Struct Engn & Bldg Mat, Technol Pk Zwijnaarde 60, B-9052 Ghent, Belgium
[2] Ecole Cent Nantes, Inst Rech Genie Civil & Mecan GeM, CNRS, UMR 6183, 1 Rue Noe, F-44321 Nantes, France
基金
欧盟地平线“2020”;
关键词
high performance concrete; internal curing; superabsorbent polymers; autogenous shrinkage; large-scale testing; WATER PERMEABILITY; CEMENT; TEMPERATURE;
D O I
10.3390/su12114741
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
High performance concrete (HPC) is a high strength concrete that undergoes a lot of early-age autogenous shrinkage (AS). If shrinkage is restrained, then micro-cracks arise and threaten the durability of the structure. Superabsorbent polymers (SAPs) can reduce/mitigate the autogenous shrinkage, due to their promising application as internal curing agents. In this paper, large-scale demonstrators were built to investigate the efficiency of SAPs to mitigate autogenous shrinkage in HPC. For this purpose, different measurement techniques were used like embedded fiber optic sensors and demountable mechanical strain gauges, complemented by AS measurements in corrugated tubes and restrained ring tests. The SAP wall showed an AS reduction of 22%, 54%, and 60% at the bottom, middle, and top, respectively, as recorded by the sensors (in comparison with the reference wall (REF)). In the corrugated tubes, mitigation of AS was shown in the SAP mixture, and under restrained conditions, in the ring test, the reference mixture cracked after two days, while the SAP mixture had not cracked at the end of the measurement period (20 days). Cracks were shown on REF wall after one day, while the SAP wall was crack-free. Water flow tests performed on the main crack of the REF wall confirmed that the flow rate is related to the third power of the crack width. All tests showed that SAPs could highly reduce AS in HPC and avoid cracking.
引用
收藏
页数:24
相关论文
共 55 条
[1]  
[Anonymous], 1980, 25PEM RILEM TC SARL, P75
[2]  
[Anonymous], 2012, STAR 225 SAP APPL SU
[3]  
[Anonymous], 2010, P INT RILEM C US SUP
[4]  
[Anonymous], 2018, CANCER DISCOV, V8, pOF6, DOI DOI 10.1617/s11527-018-1242-8
[5]  
[Anonymous], 2014, STANDARD TEST METHOD, DOI DOI 10.1520/D3039_D3039M-17
[6]  
[Anonymous], 2016, P MAT SYST STRUCT CI
[7]  
Armitage G C, 1999, Ann Periodontol, V4, P1, DOI 10.1902/annals.1999.4.1.1
[8]  
ASTM International, 2004, C158104 ASTM
[9]  
Belgian Standard, 2019, 123508 NBN EN BUR NO
[10]  
Belgian Standard, 2019, 1239032019 NBN EN BU