Association of Self-Reported Coping Strategies With Speech Recognition Outcomes in Adult Cochlear Implant Users

被引:1
作者
Espahbodi, Mana [1 ]
Harvey, Erin [1 ]
Livingston, Austin J. [2 ]
Montagne, William [2 ]
Kozlowski, Kristin [1 ]
Jensen, Jamie [1 ]
Liu, Xuerong [3 ]
Juan, Wanlin [3 ]
Tarima, Sergey [3 ]
Rusch, Mark [4 ]
Harris, Michael S. [1 ,5 ]
机构
[1] Med Coll Wisconsin, Dept Otolaryngol & Commun Sci, 9200 W Wisconsin Ave, Milwaukee, WI 53226 USA
[2] Med Coll Wisconsin, Milwaukee, WI 53226 USA
[3] Med Coll Wisconsin, Div Biostat, Milwaukee, WI 53226 USA
[4] Med Coll Wisconsin, Dept Plast Surg, Milwaukee, WI 53226 USA
[5] Med Coll Wisconsin, Dept Neurosurg, Milwaukee, WI 53226 USA
基金
美国国家卫生研究院;
关键词
Cochlear implant; Coping strategies; Speech outcomes; QUALITY-OF-LIFE; SOUND QUALITY; QUESTIONNAIRE; VALIDATION; HEARING; HEALTH;
D O I
10.1097/MAO.0000000000003621
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective To characterize the degree to which individual coping strategies may influence speech perception after cochlear implantation. Study Design Retrospective cohort study. Setting Tertiary referral center. Patients Adult, postlingually deaf cochlear implant recipients. Intervention(s) The Coping Orientation to Problems Experience inventory, a validated, multidimensional self-reported coping scale, was administered preoperatively. Main Outcome Measure(s) Speech perception was measured using consonant-nucleus-consonant (CNC) phoneme and word scores, AzBio sentence accuracy in quiet and noise, and Hearing in Noise Test sentences in quiet preoperatively and at 1, 3, and 6 months postoperatively. Quality of life was measured with the Hearing Implant Sound Quality Index and the Nijmegen Cochlear Implant Questionnaire. Results Thirty-six patients were included in this study. Mean age at surgery was 70.7 +/- 11.4 years. Acceptance was associated with a decreased AzBio in noise score in the 6 months after CI (regression coefficient b = -0.05; 95% confidence interval [CI], -0.07 to -0.03; p < 0.01). Denial was associated with a decreased AzBio in quiet score (b = -0.05; 95% CI, -0.09 to -0.01; p < 0.05), whereas humor was associated with an increased AzBio in quiet score (b = 0.02; 95% CI, 0.01 to 0.04; p < 0.05). Humor was also associated with an increased Hearing in Noise Test score (b = 0.05; 95% CI, 0.02 to 0.07; p < 0.05). Denial was associated with decreased CNC word (b = -0.04; 95% CI, -0.06 to -0.02; p < 0.01) and phoneme (b = -0.04; 95% CI, -0.07 to -0.02; p < 0.01) scores, whereas substance use was associated with increased CNC word (b = 0.03; 95% CI, 0.01 to 0.05, p < 0.01) and phoneme (b = 0.04; 95% CI, 0.02 to 0.06; p < 0.01) scores. Scores on self-reported quality of life measures were not significantly correlated with coping strategies. Conclusion A variety of adaptive and maladaptive coping strategies are used by postlingually deaf adult cochlear implant users. Denial and acceptance may be more predictive of poor speech performance, whereas humor and substance use may be more predictive of improved speech performance.
引用
收藏
页码:E888 / E894
页数:7
相关论文
共 50 条
[31]   Speech Recognition, Quality of Hearing, and Data Logging Statistics over Time in Adult Cochlear Implant Users [J].
Malzanni, Giulia Elvira ;
Lerda, Caterina ;
Battista, Rosa Alessia ;
Canova, Chiara ;
Gatti, Omar ;
Bussi, Mario ;
Piccioni, Lucia Oriella .
INDIAN JOURNAL OF OTOLOGY, 2022, 28 (01) :45-51
[32]   Is the spread of excitation width correlated to the speech recognition in cochlear implant users? [J].
da Silva, Juliana Coutinho ;
Schmidt Goffi-Gomez, Maria Valeria ;
Magalhaes, Ana Tereza ;
Tsuji, Robinson Koji ;
Bento, Ricardo Ferreira .
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 278 (06) :1815-1820
[33]   Is the spread of excitation width correlated to the speech recognition in cochlear implant users? [J].
Juliana Coutinho da Silva ;
Maria Valéria Schmidt Goffi-Gomez ;
Ana Tereza Magalhães ;
Robinson Koji Tsuji ;
Ricardo Ferreira Bento .
European Archives of Oto-Rhino-Laryngology, 2021, 278 :1815-1820
[34]   Speech Recognition of Cochlear Implant Users Inside a Noisy Helicopter Environment [J].
Araujo Caldeiraa, Juliana Maria ;
Schmidt Goffi-Gomez, Maria Valeria ;
Imamura, Rui ;
Bento, Ricardo Ferreira .
AUDIOLOGY AND NEURO-OTOLOGY, 2019, 24 (01) :32-37
[35]   Long-TermInfluence of Electrode Array Length on Speech Recognition in Cochlear Implant Users [J].
Canfarotta, Michael W. ;
Dillon, Margaret T. ;
Buchman, Craig A. ;
Buss, Emily ;
O'Connell, Brendan P. ;
Rooth, Meredith A. ;
King, English R. ;
Pillsbury, Harold C. ;
Adunka, Oliver F. ;
Brown, Kevin D. .
LARYNGOSCOPE, 2021, 131 (04) :892-897
[36]   Pupillometry Assessment of Speech Recognition and Listening Experience in Adult Cochlear Implant Patients [J].
Russo, Francesca Yoshie ;
Hoen, Michel ;
Karoui, Chadlia ;
Demarcy, Thomas ;
Ardoint, Marine ;
Tuset, Maria-Pia ;
De Seta, Daniele ;
Sterkers, Olivier ;
Lahlou, Ghizlene ;
Mosnier, Isabelle .
FRONTIERS IN NEUROSCIENCE, 2020, 14
[37]   Our experience with home self-assessment of speech recognition in the care pathway of 10 newly implanted adult cochlear implant users [J].
de Graaff, Feike ;
Huysmans, Elke ;
Philips, Birgit ;
Merkus, Paul ;
Goverts, S. Theo ;
Kramer, Sophia E. ;
Smits, Cas .
CLINICAL OTOLARYNGOLOGY, 2019, 44 (03) :446-451
[38]   Factors That Influence Second-side Cochlear Implant Speech Recognition Outcomes [J].
Dornhoffer, James ;
Liu, Yuan F. ;
Zhao, Elise E. ;
Camposeo, Elizabeth L. ;
Meyer, Ted A. ;
McRackan, Theodore R. .
OTOLOGY & NEUROTOLOGY, 2021, 42 (03) :E279-E285
[39]   Factors influencing the relationship between cochlear health measures and speech recognition in cochlear implant users [J].
Zamaninezhad, Ladan ;
Mert, Berkutay ;
Benav, Heval ;
Tillein, Jochen ;
Garnham, Carolyn ;
Baumann, Uwe .
FRONTIERS IN INTEGRATIVE NEUROSCIENCE, 2023, 17
[40]   The effect of long-term deafness on speech recognition in postlingually deafened adult CLARION® cochlear implant users [J].
Geier, L ;
Barker, M ;
Fisher, L ;
Opie, J .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1999, 108 (04) :80-83