Influence of Aged Conductor Surface Conditions on AC Corona Discharge With a Corona Cage

被引:54
|
作者
Bian, Xingming [1 ,2 ]
Yu, Deming [1 ,2 ]
Chen, Lan [1 ,2 ]
MacAlpine, J. M. K. [2 ]
Wang, Liming [2 ]
Guan, Zhicheng [1 ,2 ]
Chen, Fangdong [3 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Grad Sch Shenzhen, Lab Adv Technol Elect Engn & Energy, Shenzhen 518055, Guangdong, Peoples R China
[3] N China Grid Co Ltd, Beijing Extra High Voltage Co, Beijing 102488, Peoples R China
基金
中国国家自然科学基金;
关键词
AC corona discharge; aging; surface condition; roughness; corona cage; PERFORMANCE;
D O I
10.1109/TDEI.2011.5931069
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Relatively little investigation has previously been done on the effects of aging on conductor surface conditions, or on the ac corona discharges from these conductors. In the present work these were investigated by means of comparing corona on typical aged conductors with that on new ones. The aged conductors from the ac power transmission lines had been in service for 12, 15 and 20 years. Scanning electron microscopy (SEM) and energy-dispersive X-ray (EDX) analysis were employed to characterize the surface morphology and composition of the conductors; and a non-contact surface profiler was used to measure the surface roughness of the six samples. As a result of corrosion and the adherence of various substances to the conductors, their surfaces were far rougher than the new ones. The ac corona discharge characteristics of these conductors were studied in a small corona cage using an ultraviolet imaging detector. As a result of the rough surfaces, the corona discharge intensity for the aged conductors was found to be much stronger than that for the new ones; and the corona inception voltages for the aged conductors were 10 to 25% lower than the new ones.
引用
收藏
页码:809 / 818
页数:10
相关论文
共 50 条
  • [1] Influence of Aged Conductor Surface Conditions on AC Corona-generated Audible Noise with a Corona Cage
    Bian, Xingming
    Chen, Lan
    Yu, Deming
    MacAlpine, J. M. K.
    Wang, Liming
    Guan, Zhicheng
    Chen, Fangdong
    Yao, Wenjun
    Zhao, Shuzhen
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (06) : 2037 - 2043
  • [2] Aging effects of conductor surface conditions on AC corona discharge
    Bian, Xingming
    Zhao, Xuesong
    Cao, Jin
    Gu, Lili
    Wang, Liming
    Guan, Zhicheng
    2010 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTIC PHENOMENA, 2010,
  • [3] Influence of Medium Particles on the Corona Discharge Process of AC Conductor
    Liu, Yunpeng
    Wu, Zhenyang
    Zhu, Lei
    Liu, Yang
    INTERNATIONAL CONFERENCE ON ELECTRICAL, CONTROL AND AUTOMATION (ICECA 2014), 2014, : 565 - 571
  • [4] Influence of air pressure and humidity on positive direct current corona discharge performances of the conductor in a corona cage
    Hu, Qin
    Shu, Lichun
    Jiang, Xingliang
    Sun, Caixin
    Qiu, Zongkui
    Lin, Rui
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2014, 24 (05): : 723 - 735
  • [5] Studies of DC conductor corona in a small corona cage
    Sibilant, GC
    Ijumba, NM
    Britten, AC
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 2202 - 2207
  • [6] Studies of DC conductor corona in a small corona cage
    Sibilant, GC
    Ijumba, NM
    Britten, AC
    2002 IEEE AFRICON, VOLS 1 AND 2: ELECTROTECHNOLOGICAL SERVICES FOR AFRICA, 2002, : 661 - 664
  • [7] Influence of AC Corona Discharge on Contamination Layer of Composite Insulator Surface
    Liu, Yingyan
    Xu, Sen
    Wu, Chao
    Yao, Yiming
    Wang, Jiafu
    Bao, Weining
    Liang, Xidong
    2015 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2015, : 197 - 200
  • [8] Laboratory Investigation of AC Corona Loss and Corona Onset Voltage on a Conductor under Icing Conditions
    Yin, Fanghui
    Farzaneh, Masoud
    Jiang, Xingliang
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (03) : 1862 - 1871
  • [9] Effect of air temperature on DC conductor corona performance in corona cage
    Wang, Wei
    Ding, Yan-Sheng
    Li, Cheng-Rong
    Li, Xiao-Lin
    Luo, Bing
    Yu, Zhuang-Zhuang
    An, Bing
    Wang, Yi-Xu
    Yang, Bo
    Fan, Fei
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (03): : 613 - 617
  • [10] Measurement methods for DC conductor corona onset voltage in the corona cage
    Zhao, Yu-Ming
    Ma, Min-Hua
    Chu, Jin-Wei
    Guan, Zhi-Cheng
    Wang, Li-Ming
    Gaodianya Jishu/High Voltage Engineering, 2008, 34 (08): : 1567 - 1572