Development of 3D Printed Phantom for Dose Verification in Radiotherapy for the Patient with Metal Artefacts Inside

被引:4
作者
Adliene, Diana [1 ]
Jaselske, Evelina [1 ]
Urbonavicius, Benas Gabrielis [1 ]
Laurikaitiene, Jurgita [1 ]
Rudzianskas, Viktoras [1 ,2 ]
Didvalis, Tadas [3 ]
机构
[1] Kaunas Univ Technol, Studentu G 50, LT-51368 Kaunas, Lithuania
[2] Lithuanian Univ Hlth Sci, Inst Oncol, Eiveniu G 2, LT-50161 Kaunas, Lithuania
[3] Hosp Lithuanian Univ Hlth Sci, Kaunas Clin, Eiveniu G 2, LT-50161 Kaunas, Lithuania
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3 | 2019年 / 68卷 / 03期
关键词
Dose verification; IMRT; Metal artefacts; 3D printed patient specific phantom; MODULATED RADIATION-THERAPY; MONTE-CARLO METHOD; DENSITY; ALGORITHM; HEAD; GELS;
D O I
10.1007/978-981-10-9023-3_119
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
One of the problems performing IMRT dose planning or plan verification using anthropomorphic phantoms for head and neck cancer patients is the presence of possible artefacts (dental crowns, metal dental implants, dental restoration materials.) inside the oral cavity. In many cases these artefacts are not accounted but may cause deviations from patient treatment plans due to enhanced scattering dose from the metal artefacts. Exploiting 3D printing technologies 3D dosimetry phantom corresponding to patient-specific anatomic structures with precisely positioned artefacts can be produced. Application of such 3D phantom in radiation therapy may contribute to more accurate dose planning and thus more efficient patient treatment. In this work we propose newly developed patient-specific 3D printed phantom of lower jaw with teeth which can be used for patient specific QA in IMRT. Developing this phantom DICOM image of the real patient was used for 3D reconstruction of patient's lower jaw with teeth. 3D shape of this anatomic structure was printed out using Zortrax M300 3D printer. High Impact Polystyrene (HIPS) which is characterized as having satisfactory bone tissue equivalency was used as printing material. Keeping in mind a real patient, possibility of covering of corresponding teeth with a metallic crown in the 3D printed jaw construction was foreseen. Prepared construction was fixed in dose gel matrix, thus forming dosimetry phantom for the evaluation of possible radiation treatment errors caused by artefacts located in this anatomic region of the patient. Investigation of 3D printed lower jaw phantom has shown its feasibility for the assessment of dose distortions related to the presence of metal artefacts in the mouth of the patient. Also potential for the application of 3D printed phantoms in radiotherapy quality assurance has been shown.
引用
收藏
页码:643 / 647
页数:5
相关论文
共 29 条
[1]  
*AAPM, 2004, 85 AAPM
[2]   Application of Dose Gels in HDR Brachytherapy [J].
Adliene, D. ;
Jakstas, K. ;
Vaiciunaite, N. ;
Laurikaitiene, J. ;
Cerapaite-Trusinskiene, R. .
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 :724-727
[3]   Application of optical methods for dose evaluation in normoxic polyacrylamide gels irradiated at two different geometries [J].
Adliene, D. ;
Jakstas, K. ;
Vaiciunaite, N. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 741 :88-94
[4]  
Adliene D, 2018, NIMB62907
[5]  
Alssabbagh M, 2017, INT J ADV APPL SCI, V4, P168, DOI 10.21833/ijaas.2017.09.024
[6]   Evaluation of 3D printing materials for fabrication of a novel multi-functional 3D thyroid phantom for medical dosimetry and image quality [J].
Alssabbagh, Moayyad ;
Tajuddin, Abd Aziz ;
Abdulmanap, Mahayuddin ;
Zainon, Rafidah .
RADIATION PHYSICS AND CHEMISTRY, 2017, 135 :106-112
[7]   Dosimetric evaluation of scattered and attenuated radiation due to dental restorations in head and neck radiotherapy [J].
Azizi, Mona ;
Mowlavi, Ali Asghar ;
Ghorbani, Mahdi ;
Azadegan, Behnam ;
Akbari, Fatemeh .
JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2018, 11 (01) :23-28
[8]   Improved Survival Using Intensity-Modulated Radiation Therapy in Head and Neck Cancers [J].
Beadle, Beth M. ;
Liao, Kai-Ping ;
Elting, Linda S. ;
Buchholz, Thomas A. ;
Ang, K. Kian ;
Garden, Adam S. ;
Guadagnolo, B. Ashleigh .
CANCER, 2014, 120 (05) :702-710
[9]   Use of 3D printers to create a patient-specific 3D bolus for external beam therapy [J].
Burleson, Sarah ;
Baker, Jamie ;
Hsia, An Ting ;
Xu, Zhigang .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03) :166-178
[10]   High-density dental implants and radiotherapy planning: evaluation of effects on dose distribution using pencil beam convolution algorithm and Monte Carlo method [J].
Catli, Serap .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (05) :46-52