Recent advances in cholesterol biosensor

被引:197
作者
Arya, Sunil K. [1 ,2 ]
Datta, Monika [2 ]
Malhotra, Bansi D. [1 ]
机构
[1] Natl Phys Lab, Biomol Elect & Conducting Polymer Res Grp, New Delhi 110012, India
[2] Univ Delhi, Dept Chem, Delhi 110007, India
关键词
cholesterol oxidase; cholesterol; immobilization; transducer; biosensor; SELF-ASSEMBLED MONOLAYER; IN-SITU PREPARATION; AMPEROMETRIC DETERMINATION; CARBON NANOTUBES; STREPTOMYCES-HYGROSCOPICUS; ENZYME ELECTRODE; ELECTROCHEMICAL BIOSENSOR; OVEROXIDIZED POLYPYRROLE; CONDUCTING POLYMERS; GOLD NANOPARTICLES;
D O I
10.1016/j.bios.2007.10.018
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Biosensors have recently gained much attention in the field of health care for the management of various important analytes in a biological system. The area achieved tremendous progress from the time when the first Clark electrode for measurement of glucose was realized. Advances in the biosensor design are appearing at a high rate as these devices play increasingly important roles in our daily lives. The increasing incidences of cardiovascular diseases and cardiac arrest are major cause of death of humans world over. One of the most important reasons is hypercholesterolemia, i.e. increased concentration of cholesterol in blood. Hence estimation of cholesterol level in blood is important in clinical applications. This review aims to highlight the recent advances in materials and techniques for cholesterol biosensor design and construction. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1083 / 1100
页数:18
相关论文
共 102 条
[1]   Electrochemical study of the interaction between cytochrome P450sccK201E and cholesterol [J].
Antonini, M ;
Ghisellini, P ;
Paternolli, C ;
Nicolini, C .
TALANTA, 2004, 62 (05) :945-950
[2]   Sensitive estimation of total cholesterol in blood using Au nanowires based micro-fluidic platform [J].
Aravamudhan, Shyam ;
Kumar, Arun ;
Mohapatra, Shyam ;
Bhansali, Shekhar .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10) :2289-2294
[3]   Electrochemical biosensor for targeted detection in blood using aligned Au nanowires [J].
Aravamudhan, Shyarn ;
Ramgir, Niranjan S. ;
Bhansah, Shekhar .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (01) :29-35
[4]  
Arya Sunil K., 2006, Proceedings of the Indian National Science Academy, V72, P249
[5]   Dithiobissuccinimidyl propionate self assembled monolayer based cholesterol biosensor [J].
Arya, Sunil K. ;
Pandey, Pratibha ;
Singh, Surinder P. ;
Datta, Monika ;
Malhotra, Bansi D. .
ANALYST, 2007, 132 (10) :1005-1009
[6]   Cholesterol biosensor based on N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane self-assembled monolayer [J].
Arya, Sunil K. ;
Prusty, Arun K. ;
Singh, S. P. ;
Solanki, Pratima R. ;
Pandey, Manoj K. ;
Datta, Monika ;
Malhotra, Bansi D. .
ANALYTICAL BIOCHEMISTRY, 2007, 363 (02) :210-218
[7]   Poly-(3-hexylthiophene) self-assembled monolayer based cholesterol biosensor using surface plasmon resonance technique [J].
Arya, Sunil K. ;
Solanki, Pratima R. ;
Singh, S. P. ;
Kaneto, K. ;
Pandey, Manoj K. ;
Datta, Monika ;
Malhotra, Bansi D. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) :2516-2524
[8]   Application of octadecanethiol self-assembled monolayer to cholesterol biosensor based on surface plasmon resonance technique [J].
Arya, Sunil K. ;
Solanki, Pratima R. ;
Singh, Ravindra P. ;
Pandey, Manoj K. ;
Datta, Monika ;
Malhotra, Bansi D. .
TALANTA, 2006, 69 (04) :918-926
[9]   Development of cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on oxygen electrode for the determination of total cholesterol in food samples [J].
Basu, Anjan Kumar ;
Chattopadhyay, Parimal ;
Roychoudhuri, Utpal ;
Chakraborty, Runu .
BIOELECTROCHEMISTRY, 2007, 70 (02) :375-379
[10]   Improvement of the analytical characteristics of an enzyme electrode for free and total cholesterol via laponite clay additives [J].
Besombes, JL ;
Cosnier, S ;
Labbe, P ;
Reverdy, G .
ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) :275-280