Two dimensional rotational temperature measurement by multiline laser induced fluorescence of nitric oxide in combustion flame

被引:6
|
作者
Yorozu, M
Okada, Y
Endo, A
机构
[1] Sumitomo Heavy Industries, Ltd., Research and Development Center, Hiratsuka, Kanagawa 254, 63-30, Yuhigaoka
关键词
planar thermometry; planar laser induced fluorescence; combustion; NO;
D O I
10.1007/s10043-996-0293-1
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Two-dimensional rotational temperature measurement was performed in a stable combustion flame of premixed butane and oxygen using multiline laser induced fluorescence (LIF) of nitric oxide molecules. Multiple rotational absorption lines of A(2) Sigma(+)<--X(2) Pi(0,0) Q(1) and Q(2) lines were excited by laser light around 226 nm, and the LIF signal was observed by an image-intensified digital camera. Temperature was determined through least squares fitting correlation between LIF intensity and excitation rotational quantum number for the Boltzmann distribution function. The measured LIF intensity was approximated by the Boltzmann distribution with good accuracy, and the temperature obtained was between 500 K and 1800 K for the test flame. The measuring error of the temperature was evaluated and found to be 80 K, which corresponded to 8% of the measured fluorescence intensity. The two-line LIF scheme was evaluated by different pairs of excitation lines (Q(1)(31.5)/Q(1)(16.5) and Q(1)(18.5)/Q(1)(16.5)) for comparison with the multiline LIF approach. Temperature which was obtained by two-line LIF scheme corresponded well with multiline LIF results for Q(1)(31.5)/Q(1)(16.5) excitation. However, for Q(1)(18.5)/Q(1)(16.5) excitation, the obtained temperature did not agree with the multiline LIF result because the population of rotational states J=18.5 and J=16.5 is similar at high temperatures. We found that two-line LIF temperature measurement was reliable when excitation lines were suitably selected.
引用
收藏
页码:293 / 298
页数:6
相关论文
共 50 条
  • [1] Temperature measurement by laser induced fluorescence of nitric oxide in combustion flame
    Yorozu, M
    Okada, Y
    Endo, A
    COMBUSTION DIAGNOSTICS, 1997, 3108 : 80 - 86
  • [2] Rotational temperature measurement of NO molecule in a flame through laser-induced fluorescence spectrum
    Hayashida, K
    Shirai, H
    Amagai, K
    Arai, M
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2002, 45 (01) : 201 - 208
  • [3] Laser-induced fluorescence of seeded nitric oxide as a flame thermometer
    SRI Int, Menlo Park, United States
    Appl Phys B, 4 (503-510):
  • [4] Laser-induced fluorescence of seeded nitric oxide as a flame thermometer
    M. Tamura
    J. Luque
    J.E. Harrington
    P.A. Berg
    G.P. Smith
    J.B. Jeffries
    D.R. Crosley
    Applied Physics B, 1998, 66 : 503 - 510
  • [5] Laser-induced fluorescence of seeded nitric oxide as a flame thermometer
    Tamura, M
    Luque, J
    Harrington, JE
    Berg, PA
    Smith, GP
    Jeffries, JB
    Crosley, DR
    APPLIED PHYSICS B-LASERS AND OPTICS, 1998, 66 (04): : 503 - 510
  • [6] NITRIC-OXIDE MEASUREMENTS IN A FLAME BY LASER FLUORESCENCE
    GRIESER, DR
    BARNES, RH
    APPLIED OPTICS, 1980, 19 (05): : 741 - 743
  • [7] Measurement of two-dimensional distribution profile of lead in a flame by planar laser-induced fluorescence spectroscopy
    Kodama, Kenji
    Kitagawa, Kuniyuki
    JOURNAL OF VISUALIZATION, 2010, 13 (02) : 133 - 139
  • [8] Measurement of two-dimensional distribution profile of lead in a flame by planar laser-induced fluorescence spectroscopy
    Kenji Kodama
    Kuniyuki Kitagawa
    Journal of Visualization, 2010, 13 : 133 - 139
  • [9] Two dimensional temperature-field measurement of combustion flame depth in sudden spread combustion chamber
    Ouyang, Qi
    Xie, Zhijiang
    Wen, Liangying
    Chen, Ping
    Zhongguo Jixie Gongcheng/China Mechanical Engineering, 2007, 18 (16): : 1974 - 1979
  • [10] TWO-DIMENSIONAL IMAGING OF OH LASER-INDUCED FLUORESCENCE IN A FLAME
    DYER, MJ
    CROSLEY, DR
    OPTICS LETTERS, 1982, 7 (08) : 382 - 384