Is three-dimensional power Doppler ultrasound useful in the assessment of placental perfusion in normal and growth-restricted pregnancies?

被引:125
作者
Guiot, C. [1 ,2 ]
Gaglioti, P. [3 ]
Oberto, M. [3 ]
Piccoli, E. [3 ]
Rosato, R. [4 ,5 ]
Todros, T. [3 ]
机构
[1] Univ Turin, Dept Neurosci, I-10125 Turin, Italy
[2] Univ Turin, CNISM, I-10125 Turin, Italy
[3] Univ Turin, Dept Obstet & Gynecol, I-10125 Turin, Italy
[4] Univ Turin, Dept Psychol, I-10125 Turin, Italy
[5] Univ Turin, CPO, I-10125 Turin, Italy
关键词
3D ultrasound; fetal growth restriction; placenta; umbilical Doppler;
D O I
10.1002/uog.5212
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To investigate three-dimensional (3D) power Doppler ultrasound indices in the assessment of placental perfusion and their relationship to gestational age (GA), placental position and umbilical artery Doppler flow velocity waveform (FVW) patterns in normal and intrauterine growth-restricted (IUGR) pregnancies. Methods Forty-five pregnant women at 23-37 weeks' gestation were studied, of whom 30 had lUGR and 15 were controls. Nine of the IUGR group had normal umbilical FVWs (NED), nine had abnormal patterns but positive end-diastolic velocities (PED) and 12 had absent or reversed end-diastolic velocities (AED). Placental position was assessed as being posterior, anterior or lateral. 3D power Doppler indices related to placental perfusion (vascularization index (VI), vascularization flow index (VFI) and flow index (FI)) were obtained from five different sampling sites in each placenta. Results VI, VFI and FI were not significantly dependent on GA or placental position. VI and VFI were significantly lower in PED and AED cases compared with controls, while FI was reduced in the AED group only. VI and VFI showed high variability between different sampling sites within each placenta, while the variability of FI was much lower. Conclusions 3D power Doppler sonograpby can provide new insights into placental pathophysiology. Fl, which identifies the most severe cases of placental impairment, appears to be the most reliable index because of its low intraplacental variability. Further studies are needed to verify its accuracy when applied in clinical practice as a substitute for or an adjunct to umbilical artery Doppler studies. Copyright (c) 2008 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:171 / 176
页数:6
相关论文
共 17 条
[11]  
Parazzini F, 1998, Pediatr Med Chir, V20, P93
[12]   Decreased endovascular trophoblast invasion in first trimester pregnancies with high-resistance uterine artery Doppler indices [J].
Prefumo, F ;
Sebire, NJ ;
Thilaganathan, B .
HUMAN REPRODUCTION, 2004, 19 (01) :206-209
[13]   EARLY DOPPLER ULTRASOUND SCREENING IN PREDICTION OF HYPERTENSIVE DISORDERS OF PREGNANCY [J].
STEEL, SA ;
PEARCE, JM ;
MCPARLAND, P ;
CHAMBERLAIN, GVP .
LANCET, 1990, 335 (8705) :1548-1551
[14]   MODELING THE FETOPLACENTAL CIRCULATION .2. A CONTINUOUS APPROACH TO EXPLAIN NORMAL AND ABNORMAL FLOW VELOCITY WAVE-FORMS IN THE UMBILICAL ARTERIES [J].
TODROS, T ;
GUIOT, C ;
PIANTA, PG .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1992, 18 (6-7) :545-551
[15]   Accuracy of the umbilical arteries Doppler flow velocity waveforms in detecting adverse perinatal outcomes in a high-risk population [J].
Todros, T ;
Ronco, G ;
Fianchino, O ;
Rosso, S ;
Gabrielli, S ;
Valsecchi, L ;
Spagnolo, D ;
Acanfora, L ;
Biolcati, M ;
Segnan, N ;
Pilu, GL .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1996, 75 (02) :113-119
[16]  
Wijman MJ, 2004, J SOC GYNECOL INVEST, V11, p223A
[17]  
Yu CH, 2003, ULTRASOUND MED BIOL, V29, P19, DOI 10.1016/S0301-5629(03)00136-4