Comparison and optimization of various moving patient-based real-time quality control procedures for serum sodium

被引:13
作者
Li, Yuanyuan [1 ,2 ,3 ]
Yu, Qian [1 ,2 ,3 ]
Zhang, Xiaoyan [1 ,2 ,3 ]
Chen, Xiaoling [1 ,2 ,3 ]
机构
[1] Zhejiang Univ, Affiliated Hosp 1, Coll Med, Dept Lab Med, Hangzhou, Peoples R China
[2] Key Lab Clin In Vitro Diagnost Tech Zhejiang Prov, Hangzhou, Peoples R China
[3] Zhejiang Univ, Inst Lab Med, Hangzhou, Peoples R China
关键词
moving average; moving median; moving proportion of normal results; moving standard deviation; patient-based real-time quality control; AVERAGE; TOOLS; SUM;
D O I
10.1002/jcla.23985
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Patient-based real-time quality control (PBRTQC) is a valuable tool for monitoring the performance of testing processes. We aimed to compare and optimize various PBRTQC procedures for serum sodium. Methods In a computer simulation, artificial errors were added to 680,000 real patients' results. The characteristics of error detection of various algorithms-moving average, moving median, moving SD and moving proportion of normal results including different control limits (CLs)-were assessed on their ability to detect critical errors early. Results The moving average and moving median were sensitive to system error, and the moving SD tended to detect random error. P-3SD (moving proportion of normal results, CLs based on mean and SD of proportion of normal results) demonstrated excellent performance for both system error and random error. The increase of block sizes (N) leads to the delay of error detection and the decrease of false rejection, except for QC procedures with minimum and maximum as CLs. CLs calculation with "0.1% false alarm rate" had more effective performance than that set false alarm to zero (minimum and maximum as CLs). The impact of truncation on QC performance depended on truncation limits, algorithms and the types of error. The significant improvement in QC performance due to truncation was only found in moving SD. Conclusion "P-3SD,N = 50, without truncation" and "moving SD, N = 25, set 0.1% false alarm as CLs and set 1% outliers exclusion as truncation limits" were recommended as the optimized procedures for serum sodium to monitor system error and random error, respectively.
引用
收藏
页数:14
相关论文
共 24 条
[1]   Failure of Current Laboratory Protocols to Detect Lot-to-Lot Reagent Differences: Findings and Possible Solutions [J].
Algeciras-Schimnich, Alicia ;
Bruns, David E. ;
Boyd, James C. ;
Bryant, Sandra C. ;
La Fortune, Kristin A. ;
Grebe, Stefan K. G. .
CLINICAL CHEMISTRY, 2013, 59 (08) :1187-1194
[2]   Patient-Based Real-Time Quality Control: Review and Recommendations [J].
Badrick, Tony ;
Bietenbeck, Andreas ;
Cervinski, Mark A. ;
Katayev, Alex ;
van Rossum, Huub H. ;
Loh, Tze Ping .
CLINICAL CHEMISTRY, 2019, 65 (08) :962-971
[3]   Understanding Patient-Based Real-Time Quality Control Using Simulation Modeling [J].
Bietenbeck, Andreas ;
Cervinski, Mark A. ;
Katayev, Alex ;
Loh, Tze Ping ;
van Rossum, Huub H. ;
Badrick, Tony .
CLINICAL CHEMISTRY, 2020, 66 (08) :1072-1083
[4]   Sigma Metrics Across the Total Testing Process [J].
Charuruks, Navapun .
CLINICS IN LABORATORY MEDICINE, 2017, 37 (01) :97-+
[5]   Patient pools and the use of "patient means" are valuable tools in quality control illustrated by a bone-specific alkaline phosphatase assay [J].
Hinge, Maja ;
Lund, Erik D. ;
Brandslund, Ivan ;
Plesner, Torben ;
Madsen, Jonna S. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (03) :403-406
[6]  
HOFFMANN RG, 1965, AM J CLIN PATHOL, V43, P134
[7]   Average of delta: a new quality control tool for clinical laboratories [J].
Jones, Graham R. D. .
ANNALS OF CLINICAL BIOCHEMISTRY, 2016, 53 (01) :133-140
[8]   Median of patient results as a tool for assessment of analytical stability [J].
Jorgensen, Lars Monster ;
Hansen, Steen Ingemann ;
Petersen, Per Hyltoft ;
Soletormos, Gyorgy .
CLINICA CHIMICA ACTA, 2015, 446 :186-191
[9]   Moving standard deviation and moving sum of outliers as quality tools for monitoring analytical precision [J].
Liu, Jiakai ;
Tan, Chin Hon ;
Badrick, Tony ;
Loh, Tze Ping .
CLINICAL BIOCHEMISTRY, 2018, 52 :112-116
[10]   Moving sum of number of positive patient results as a quality control tool [J].
Liu, Jiakai ;
Tan, Chin Hon ;
Badrick, Tony ;
Loh, Tze Ping .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (11) :1709-1714