Long-term durability of bicuspid aortic valve repair: a comparison of 2 annuloplasty techniques

被引:26
作者
de Meester, Christophe [1 ]
Vanovershelde, Jean-Louis [1 ,2 ]
Jahanyar, Jama [3 ]
Tamer, Saadallah [3 ]
Mastrobuoni, Stefano [1 ,3 ]
Van Dyck, Michel [4 ]
Navarra, Emiliano [1 ,3 ]
Poncelet, Alain [1 ,3 ]
Astarci, Parla [1 ,3 ]
el Khoury, Gebrine [1 ,3 ]
de Kerchove, Laurent [1 ,3 ]
机构
[1] Univ Catholique Louvain UCL, Inst Rech Expt & Clin IREC, Pole Rech Cardiovasc, Louvain La Neuve, Belgium
[2] Clin Univ St Luc, Div Cardiol, Brussels, Belgium
[3] Clin Univ St Luc, Div Cardiothorac & Vasc Surg, Dept Cardiovasc Med, Brussels, Belgium
[4] Clin Univ St Luc, Div Anesthesiol, Dept Acute Med, Brussels, Belgium
关键词
Valve repair; Bicuspid; Valve sparing; Annuloplasty; ROOT REPLACEMENT; RING; REGURGITATION; OPERATION; DIMENSION;
D O I
10.1093/ejcts/ezaa471
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: To compare long-term outcomes after bicuspid aortic valve (BAV) repair utilizing the Cabrol annuloplasty versus valve sparing Reimplantation technique. METHODS: From 1996 to 2018, 340 consecutive patients underwent BAV repair. Eighty underwent Cabrol annuloplasty and 189 underwent Reimplantation. Exclusion criteria were re-repairs (n = 6), active endocarditis (n = 4), no annuloplasty (n = 41) and ring or suture annuloplasty (n = 20). We compared both groups for survival, reoperations, valve related events and recurrent severe aortic regurgitation (R > 2+). Inverse probability weighting (IPW) was used to balance the 2 groups. Cox regression analysis was used to identify outcome predictors. RESULTS: After weighting, pre- and intraoperative characteristics were similar between groups, except for aorta replacement techniques and operative time, which was longer in the Reimplantation group (P < 0.001). At 12 years, overall survival was similar between groups (IPW: Cabrol 97 +/- 2% vs Reimplantation 94 +/- 3%, P = 0.52). Freedom from reoperation and freedom from AR > 2+ were significantly lower in the Cabrol group (reoperation IPW: 69 +/- 9% vs 91 +/- 4%, P = 0.004 and AR > 2+ IPW: 71 +/- 8% vs 97 +/- 2%, P < 0.001). The Reimplantation technique was the only independent predictor of reoperation (hazard ratio 0.31; confidence interval 0.19-0.7; P = 0.005). CONCLUSIONS: In this study, comparing 2 annuloplasty strategies for BAV repair, we found statistically significant differences in long-term durability favouring the Reimplantation technique, and no differences in overall survival. The results support our current strategy of Reimplantation technique and repair of AR in patients with BAV. Cabrol annuloplasty is obsolete and should be generally abandoned in patients undergoing BAV repair for AR.
引用
收藏
页码:286 / 294
页数:9
相关论文
共 29 条
[1]   Valve Configuration Determines Long-Term Results After Repair of the Bicuspid Aortic Valve [J].
Aicher, Diana ;
Kunihara, Takashi ;
Abou Issa, Omar ;
Brittner, Brigitte ;
Graeber, Stefan ;
Schaefers, Hans-Joachim .
CIRCULATION, 2011, 123 (02) :178-185
[2]   Guidelines for reporting mortality and morbidity after cardiac valve interventions [J].
Akins, Cary W. ;
Miller, D. Craig ;
Turina, Marko I. ;
Kouchoukos, Nicholas T. ;
Blackstone, Eugene H. ;
Grunkemeier, Gary L. ;
Takkenberg, Johanna J. M. ;
David, Tirone E. ;
Butchart, Eric G. ;
Adams, David H. ;
Shahian, David M. ;
Hagl, Siegfried ;
Mayer, John E. ;
Lytle, Bruce W. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 33 (04) :523-528
[3]   Balance diagnostics for comparing the distribution of baseline covariates between treatment groups in propensity-score matched samples [J].
Austin, Peter C. .
STATISTICS IN MEDICINE, 2009, 28 (25) :3083-3107
[4]  
Cabrol C, 1966, Arch Mal Coeur Vaiss, V59, P1305
[5]   Intermediate-term durability of bicuspid aortic valve repair for prolapsing leaflet [J].
Casselman, FP ;
Gillinov, AM ;
Akhrass, R ;
Kasirajana, V ;
Blackstone, EH ;
Cosgrove, DM .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 15 (03) :302-308
[6]  
Cosgrove D M 3rd, 1992, Ann Thorac Surg, V54, P1014
[7]   AN ANATOMIC AND PHYSIOLOGICAL APPROACH TO ACQUIRED HEART-DISEASE - 8TH ANNUAL-MEETING OF THE EUROPEAN CARDIOTHORACIC ASSOCIATION, THE HAGUE, NETHERLANDS, SEPTEMBER 25-28, 1994 [J].
DAVID, TE .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1995, 9 (04) :175-180
[8]  
DAVID TE, 1992, J THORAC CARDIOV SUR, V103, P617
[9]   Variability of repairable bicuspid aortic valve phenotypes: towards an anatomical and repair-oriented classification [J].
de Kerchove, Laurent ;
Mastrobuoni, Stefano ;
Froede, Lennart ;
Tamer, Saadallah ;
Boodhwani, Munir ;
van Dyck, Michel ;
el Khoury, Gebrine ;
Schaefers, Hans-Joachim .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (02) :351-359
[10]   The role of annular dimension and annuloplasty in tricuspid aortic valve repair [J].
de Kerchove, Laurent ;
Mastrobuoni, Stefano ;
Boodhwani, Munir ;
Astarci, Parla ;
Rubay, Jean ;
Poncelet, Alain ;
Vanoverschelde, Jean-Louis ;
Noirhomme, Philippe ;
El Khoury, Gebrine .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (02) :428-438