Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research

被引:60
作者
Al-Fakih, Ebrahim A. [1 ]
Abu Osman, Noor Azuan [1 ]
Adikan, Faisal Rafiq Mahmad [2 ]
机构
[1] Univ Malaya, Fac Engn, Dept Biomed Engn, Kuala Lumpur 50603, Malaysia
[2] Univ Malaya, Fac Engn, Dept Elect Engn, Kuala Lumpur 50603, Malaysia
关键词
prosthetic sockets; transtibial amputee; pressure measurement transducers; interface stress investigations; PTB sockets; TSB sockets; liners; suspension systems; biomechanics; PATELLAR-TENDON-BEARING; BRAGG GRATING SENSORS; FIBER-OPTIC SENSORS; BELOW-KNEE PROSTHESES; TRANS-TIBIAL STUMP; OF-THE-ART; PRESSURE SENSOR; SUSPENSION SYSTEMS; SHEAR STRESSES; RESIDUAL LIMB;
D O I
10.3390/s16071119
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The distribution of interface stresses between the residual limb and prosthetic socket of a transtibial amputee has been considered as a direct indicator of the socket quality fit and comfort. Therefore, researchers have been very interested in quantifying these interface stresses in order to evaluate the extent of any potential damage caused by the socket to the residual limb tissues. During the past 50 years a variety of measurement techniques have been employed in an effort to identify sites of excessive stresses which may lead to skin breakdown, compare stress distributions in various socket designs, and evaluate interface cushioning and suspension systems, among others. The outcomes of such measurement techniques have contributed to improving the design and fitting of transtibial sockets. This article aims to review the operating principles, advantages, and disadvantages of conventional and emerging techniques used for interface stress measurements inside transtibial sockets. It also reviews and discusses the evolution of different socket concepts and interface stress investigations conducted in the past five decades, providing valuable insights into the latest trends in socket designs and the crucial considerations for effective stress measurement tools that lead to a functional prosthetic socket.
引用
收藏
页数:30
相关论文
共 155 条
[1]   The patellar tendon bar! Is it a necessary feature? [J].
Abu Osman, N. A. ;
Spence, W. D. ;
Solomonidis, S. E. ;
Paul, J. P. ;
Weir, A. M. .
MEDICAL ENGINEERING & PHYSICS, 2010, 32 (07) :760-765
[2]   Transducers for the determination of the pressure and shear stress distribution at the stump-socket interface of trans-tibial amputees [J].
Abu Osman, N. A. ;
Spence, W. D. ;
Solomonidis, S. E. ;
Paul, J. P. ;
Weir, A. M. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2010, 224 (B8) :1239-1250
[3]   Advances in Bio-Tactile Sensors for Minimally Invasive Surgery Using the Fibre Bragg Grating Force Sensor Technique: A Survey [J].
Abushagur, Abdulfatah A. G. ;
Arsad, Norhana ;
Reaz, Mamun Ibne ;
Bakar, A. Ashrif A. .
SENSORS, 2014, 14 (04) :6633-6665
[4]   The Use of Fiber Bragg Grating Sensors in Biomechanics and Rehabilitation Applications: The State-of-the-Art and Ongoing Research Topics [J].
Al-Fakih, Ebrahim ;
Abu Osman, Noor Azuan ;
Adikan, Faisal Rafiq Mahamd .
SENSORS, 2012, 12 (10) :12890-12926
[5]   Development and Validation of Fiber Bragg Grating Sensing Pad for Interface Pressure Measurements Within Prosthetic Sockets [J].
Al-Fakih, Ebrahim A. ;
Abu Osman, Noor Azuan ;
Adikan, Faisal Rafiq Mahamd ;
Eshraghi, Arezoo ;
Jahanshahi, Peyman .
IEEE SENSORS JOURNAL, 2016, 16 (04) :965-974
[6]   The Capability of Fiber Bragg Grating Sensors to Measure Amputees' Trans-Tibial Stump/Socket Interface Pressures [J].
Al-Fakih, Ebrahim A. ;
Abu Osman, Noor Azuan ;
Eshraghi, Arezoo ;
Adikan, Faisal Rafiq Mahamd .
SENSORS, 2013, 13 (08) :10348-10357
[7]  
Ali S, 2015, EUR J PHYS REHAB MED, V51, P31
[8]   Interface pressure in transtibial socket during ascent and descent on stairs and its effect on patient satisfaction [J].
Ali, Sadeeq ;
Abu Osman, Noor Azuan ;
Eshraghi, Arezoo ;
Gholizadeh, Hossein ;
bin Abd Razak, Nasrul Anwar ;
Abas, Wan Abu Bakar Bin Wan .
CLINICAL BIOMECHANICS, 2013, 28 (9-10) :994-999
[9]   Qualitative Study of Prosthetic Suspension Systems on Transtibial Amputees' Satisfaction and Perceived Problems With Their Prosthetic Devices [J].
Ali, Sadeeq ;
Abu Osman, Noor Azuan ;
Naqshbandi, Mohammad Muzamil ;
Eshraghi, Arezoo ;
Kamyab, Mojtaba ;
Gholizadeh, Hossein .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (11) :1919-1923
[10]   Clinical investigation of the interface pressure in the trans-tibial socket with Dermo and Seal-In X5 liner during walking and their effect on patient satisfaction [J].
Ali, Sadeeq ;
Abu Osman, Noor Azuan ;
Mortaza, Niyousha ;
Eshraghi, Arezoo ;
Gholizadeh, Hossein ;
Abas, Wan Abu Bakar Bin Wan .
CLINICAL BIOMECHANICS, 2012, 27 (09) :943-948