Optic disc measurements in myopia with optical coherence tomography and confocal scanning laser ophthalmoscopy

被引:130
作者
Leung, Christopher Kai-shun [1 ]
Cheng, Arthur Chak Kwan [1 ]
Chong, Kelvin Kam Lung [1 ]
Leung, King Sai [1 ]
Mohamed, Shaheeda [1 ]
Lau, Charles Sing Lok [1 ]
Cheung, Carol Yim Lui [1 ]
Chu, Geoffrey Chin-hung [1 ]
Lai, Ricky Yiu Kwong [1 ]
Pang, Calvin Chi Pui [1 ]
Lam, Dennis Shun Chiu [1 ]
机构
[1] Chinese Univ Hong Kong, Hong Kong Eye Hosp, Dept Ophthalmol & Visual Sci, Kowloon, Hong Kong, Peoples R China
关键词
D O I
10.1167/iovs.06-1315
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To evaluate the relationships between optic disc measurements, obtained by an optical coherence tomograph and a confocal scanning laser ophthalmoscope, and myopia. METHODS. One hundred thirty-three eyes from 133 healthy subjects with mean spherical equivalent -6.0 +/- 4.2 D ( range, -13.13 to + 3.25 D) were analyzed. Optic disc measurements including disc area, rim area, cup area, cup-to-disc area, and vertical and horizontal ratios were obtained with an optical coherence tomograph (StratusOCT; Carl Zeiss Meditec Inc., Dublin, CA) and a confocal scanning laser ophthalmoscope (Heidelberg Retina Tomograph, HRT 3; Heidelberg Engineering, GmbH, Dossenheim, Germany). The modified axial length method derived from prior published work was used to correct the OCT measurements for ocular magnification. Bland-Altman plots were used to evaluate the agreement for each optic disc parameter. Associations between optic disc area and axial length/spherical equivalent were evaluated by linear regression analysis. RESULTS. Disc area increased with the axial length/negative spherical equivalent in the HRT and the corrected OCT measurements although opposite directions of associations were found when the OCT measurements were not corrected for magnification. The difference of the corrected OCT and HRT disc area (corrected OCT disc area minus HRT disc area) was correlated with the axial length (r = 0.195, P = 0.025). When the ametropia was limited to -8.0 to +4.0 D, the correlations became insignificant in the HRT. Using the corrected OCT measurements, disc area, rim area, and cup area, cup-to-disc area, and cup-to-disc horizontal and vertical ratios were significantly larger than those measured by the HRT, with a span of 95% limits of agreement at 1.99, 1.33, and 1.86 mm(2) for the areas, 0.34, 0.53, and 0.58 for the ratios, respectively. CONCLUSIONS. While optic disc area generally increased with the axial length and myopic refraction, the HRT measurements demonstrated that optic disc size was largely independent of axial length and refractive error between -8 and +4 D. OCT may overestimate optic disc size in myopic eyes and results in poor agreement between the two instruments.
引用
收藏
页码:3178 / 3183
页数:6
相关论文
共 26 条
[1]  
BECK RW, 1984, OPHTHALMOLOGY, V91, P1334
[2]   CORRECTION OF OPTIC DISK MEASUREMENTS ON FUNDUS PHOTOGRAPHS [J].
BENGTSSON, B ;
KRAKAU, CET .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1992, 230 (01) :24-28
[3]   IMPROVEMENTS ON LITTMANN METHOD OF DETERMINING THE SIZE OF RETINAL FEATURES BY FUNDUS PHOTOGRAPHY [J].
BENNETT, AG ;
RUDNICKA, AR ;
EDGAR, DF .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1994, 232 (06) :361-367
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Histomorphometry of the optic disc in highly myopic eyes with absolute secondary angle closure glaucoma [J].
Dichtl, A ;
Jonas, JB ;
Naumann, GOH .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (03) :286-289
[6]   Measurement of optic disc size: equivalence of methods to correct for ocular magnification [J].
Garway-Heath, DF ;
Rudnicka, AR ;
Lowe, T ;
Foster, PJ ;
Fitzke, FW ;
Hitchings, RA .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (06) :643-649
[7]   Optic disk size in open-angle glaucoma: The Blue Mountains Eye Study [J].
Healey, PR ;
Mitchell, P .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 128 (04) :515-517
[8]   Agreement among 3 optical imaging methods for the assessment of optic disc topography [J].
Hoffmann, EM ;
Bowd, C ;
Medeiros, FA ;
Boden, C ;
Grus, FH ;
Bourne, RR ;
Zangwill, LM ;
Weinreb, RN .
OPHTHALMOLOGY, 2005, 112 (12) :2149-2156
[9]   Morphometric assessment of normal, suspect and glaucomatous optic discs with Stratus OCT and HRT II [J].
Iliev, M. E. ;
Meyenberg, A. ;
Garweg, J. G. .
EYE, 2006, 20 (11) :1288-1299
[10]   Optic disk size correlated with refractive error [J].
Jonas, JB .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (02) :346-348