Research on the stress corrosion and cathodic protection of API X80 steel under AC stray current interference

被引:5
作者
Guo, Yanbao [1 ]
Liu, Zhenyuan [1 ,2 ]
Huang, Hui [3 ]
Wang, Deguo [1 ]
He, Renyang [3 ]
机构
[1] China Univ Petr, Coll Mech & Transportat Engn, Beijing, Peoples R China
[2] State Grid Intelligent Technol Co Ltd, Jinan, Peoples R China
[3] China Special Equipment Inspect & Res Inst, Beijing, Peoples R China
关键词
Cathodic protection; X80; steel; Alternating current interference; Stress corrosion;
D O I
10.1108/ACMM-03-2021-2463
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
Purpose The corrosion of buried steel pipelines is becoming more serious because of stress corrosion, stray current corrosion and other reasons. This paper aims to study the various alternating current (AC) interference densities on the stress corrosion cracking behaviors of X80 steel samples under cathodic protection (CP) in the simulated soil electrolyte environment by using an electrochemical method. Design/methodology/approach The change of corrosion rate and surface morphology of the X80 steel samples at various AC current densities from 0 to 150 A/m(2) or CP potential between -750 and -1,200 mV in the soil-simulating environment was revealed by the electrochemical methods and slow strain rate testing methods. Findings The results revealed that with the increase of interference density, the corrosion potential of the X80 steel samples shifted to the negative side, and the corrosion pitting was observed on the surface of the sample, this may cause a danger of energy leak. Moreover, the corrosion rate was found to follow a corresponding change with the stress-strain curve. Besides, with the introduction of the CP system, the corrosion rate of the X80 steel working electrode decreased at a low cathodic potential, while showed an opposite behavior at high cathodic potential. In this study, the correlation between AC stray current, cathodic potential and stress was established, which is beneficial to the protection of oil and gas pipeline. Originality/value Investigation results are of benefit to provide a new CP strategy under the interference of AC stray current corrosion and stress corrosion to reduce the corrosion rate of buried pipelines and improve the safety of pipeline transportation.
引用
收藏
页码:346 / 353
页数:8
相关论文
共 16 条
[1]   On the Mechanism of Cathodic Protection and Its Implications on Criteria Including AC and DC Interference Conditions [J].
Buchler, Markus .
CORROSION, 2020, 76 (05) :451-463
[2]  
Cao C.N, 2008, PRINCIPLE ELECTROCHE
[3]   Effect of cathodic protection on corrosion of pipeline steel under disbonded coating [J].
Chen, X. ;
Li, X. G. ;
Du, C. W. ;
Cheng, Y. F. .
CORROSION SCIENCE, 2009, 51 (09) :2242-2245
[4]  
Correa, 2013, SP01692013 NACE
[5]  
European standard, 2013, CENTS15280 BSI STAND
[6]   Experimental research on the corrosion of X series pipeline steels under alternating current interference [J].
Guo, Yanbao ;
Meng, Tao ;
Wang, Deguo ;
Tan, Hai ;
He, Renyang .
ENGINEERING FAILURE ANALYSIS, 2017, 78 :87-98
[7]   Effects of alternating current interference on the cathodic protection for API 5L X60 pipeline steel [J].
Guo, Yanbao ;
Tan, Hai ;
Meng, Tao ;
Wang, Deguo ;
Liu, Shuhai .
JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2016, 36 :414-423
[8]   Corrosion product force measurements in the study of exfoliation and stress corrosion cracking in high strength aluminium alloys [J].
McNaughtan, D ;
Worsfold, M ;
Robinson, MJ .
CORROSION SCIENCE, 2003, 45 (10) :2377-2389
[9]  
NACE, 2020, TM0198 NACE INT
[10]   Early stage beneficial effects of cathodic protection in concrete structures [J].
Polder, R. B. ;
Peelen, W. H. A. ;
Stoop, B. Th. J. ;
Neeft, E. A. C. .
MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2011, 62 (02) :105-110