Ion transfer stripping voltammetry to detect nanomolar concentrations of Cr (VI) in drinking water

被引:20
作者
Izadyar, Anahita [1 ]
Al-Amoody, Fatma [1 ]
Arachchige, Dinusha Ranawaka [1 ]
机构
[1] Arkansas State Univ, Dept Chem & Phys, POB 419, State Univ, AR 72467 USA
关键词
Double polymer membrane; Ion transfer stripping voltammetry (ITSV); Hexavalent chromium (Cr (VI)); GC (glass carbon electrode) - POT (poly (3-octylthiophene))/PVC (poly (vinyl chloride))-modified electrode; SELECTIVE ELECTRODES; SOLID-CONTACT; PLATINUM-ELECTRODE; AQUEOUS-SOLUTION; TRACE CHROMIUM; CR(VI); SPECIATION; SAMPLES; PRECONCENTRATION; SPECTROMETRY;
D O I
10.1016/j.jelechem.2016.10.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A double polymer membrane modified glass carbon electrode with poly (3-octylthiophene) (POT) was developed for trace analysis of Cr (VI) in the form of hydrogen chromate ions (HCrO4-) in an acidic solution (pH 2.0). POT was electrochemically polymerized on glassy carbon (GC) electrode surfaces by cyclic voltammetry (-0.1-2.5 V, 100 mV s(-1), four cycles). Subsequently, a 54 plasticized poly (vinyl chloride) (PVC) was drop cast onto the POT as a second polymer, forming a double-polymer membrane. This modified electrode's stripping voltammetric current demonstrated an enhanced response to the hydrogen chromate ion, achieving a lower limit of detection of 12 nM (nanomolar). Operated in the stripping voltammetric mode, this GC - POT/PVC - modified electrode had a linear current response between 30 nM and 1300 nM in drinking water. The electrode demonstrates good selectivity relative to ClO4- and NO3- ions; the lower limit of detection of hydrogen chromate was 20 and 16 nM for ClO4- and NO3- ions, respectively. All solutions were prepared in tap water, which contains Cl-, F-, and CO32- ions at mg levels. These measurements could provide information on the lipophilicity of different toxins, leading to a better understanding of their environmental toxicity and the risks they pose to humans. Published by Elsevier B.V.
引用
收藏
页码:43 / 49
页数:7
相关论文
共 43 条
[1]   Carbon nanotube composite coated platinum electrode for detection of Cr(III) in real samples [J].
Abbaspour, Abdolkarim ;
Izadyar, Anahita .
TALANTA, 2007, 71 (02) :887-892
[2]   Platinum electrode coated with a bentonite-carbon composite as an environmental sensor for detection of lead [J].
Abbaspour, Abdolkarim ;
Izadyar, Anahita .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (05) :1559-1565
[3]  
Benefield L. D., 1982, PROCESS CHEM WATER W, P433
[4]   Revised Pourbaix diagrams for chromium at 25-300 degrees C [J].
Beverskog, B ;
Puigdomenech, I .
CORROSION SCIENCE, 1997, 39 (01) :43-57
[5]   THE DETERMINATION OF THE CHROMIUM SPECIATION IN SEA-WATER USING CATALYTIC CATHODIC STRIPPING VOLTAMMETRY [J].
BOUSSEMART, M ;
VAN DEN BERG, CMG ;
GHADDAF, M .
ANALYTICA CHIMICA ACTA, 1992, 262 (01) :103-115
[6]   DETERMINATION OF CHROMIUM(VI) IN NATURAL-WATERS BY DIFFERENTIAL PULSE POLAROGRAPHY [J].
CROSMUN, ST ;
MUELLER, TR .
ANALYTICA CHIMICA ACTA, 1975, 75 (01) :199-205
[7]   Electrochemical Ion Transfer with Thin Films of Poly(3-octylthiophene) [J].
Cuartero, Maria ;
Acres, Robert G. ;
De Marco, Roland ;
Bakker, Eric ;
Crespo, Gaston A. .
ANALYTICAL CHEMISTRY, 2016, 88 (13) :6939-6946
[8]   Ionophore-Based Voltammetric Ion Activity Sensing with Thin Layer Membranes [J].
Cuartero, Maria ;
Crespo, Gaston A. ;
Bakker, Eric .
ANALYTICAL CHEMISTRY, 2016, 88 (03) :1654-1660
[9]   Critical Review and Rethinking of USEPA Secondary Standards for Maintaining Organoleptic Quality of Drinking Water [J].
Dietrich, Andrea M. ;
Burlingame, Gary A. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (02) :708-720
[10]   Solid phase microextraction and determination of dichromate in aqueous solution based on pine needle powder-modified carbon paste electrode by potentiometry [J].
Dong, Guobin ;
Zhu, Yongchun ;
Tian, Hong ;
Li, Fei ;
Xin, Shigang ;
Qin, Yan .
RESEARCH ON CHEMICAL INTERMEDIATES, 2015, 41 (02) :1191-1201