Semi-automated echocardiographic quantification of right ventricular size and function

被引:13
作者
Medvedofsky, Diego [1 ]
Addetia, Karima [1 ]
Hamilton, Jamie [2 ]
Leon Jimenez, Javier [3 ]
Lang, Roberto M. [1 ]
Mor-Avi, Victor [1 ]
机构
[1] Univ Chicago, Med Ctr, Dept Med, Cardiol Sect, Chicago, IL 60637 USA
[2] Epsilon Imaging, Ann Arbor, MI USA
[3] Jerez de la Frontera Hosp, Cadiz, Spain
关键词
Right ventricle; Ventricular function; Echocardiography; Automated quantification; AUTOMATED BORDER DETECTION; TIME 3-DIMENSIONAL ECHOCARDIOGRAPHY; PROGNOSTIC VALUE; EJECTION FRACTION; BOUNDARY DETECTION; SYSTOLIC FUNCTION; REFERENCE VALUES; HEART-FAILURE; STRAIN; VOLUME;
D O I
10.1007/s10554-015-0672-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although parameters of right ventricular (RV) size and function are clinically important, echocardiographic assessment of this chamber is complex. Existing quantitative approaches rely on manual measurements performed on different images, and are thus time-consuming. Consequently, in clinical practice, qualitative assessment is usually used instead. We tested a new approach for automated measurements of RV size and function using speckle tracking by comparing them to the conventional manual methodology. Transthoracic images were obtained in 149 patients with a wide range of RV size and function, and were analyzed by an expert using conventional techniques to obtain RV end-diastolic and end-systolic areas, fractional area change, dimensions (basal and mid-cavity diameters and length), tricuspid annular plane systolic excursion and peak systolic velocity. Same parameters were obtained using the semi-automated software (Epsilon Imaging), which requires tracing of the RV endocardial boundary in a single frame in the RV focused view. Fifteen patients were excluded due to image quality (90 % feasibility). Time required for the automated analysis was approximately 30 s per patient, compared to 4 min for conventional analysis. The parameters obtained with the semi-automated approach were in good agreement with manual measurements: r-values 0.79-0.95 for RV size and 0.70-0.74 for function indices and biases of 2-22 % of the mean measured values, which were comparable to the intrinsic variability of the conventional technique. In conclusion, the semi-automated technique is feasible, fast and provides quantitative parameters of RV size and function, which are comparable to conventional measurements.
引用
收藏
页码:1149 / 1157
页数:9
相关论文
共 45 条
  • [21] Mor-Avi V, 1995, J Am Soc Echocardiogr, V8, P679, DOI 10.1016/S0894-7317(05)80382-7
  • [22] Morrissey R L, 1994, J Am Soc Echocardiogr, V7, P107
  • [23] Right Ventricular Global Longitudinal Strain Provides Prognostic Value Incremental to Left Ventricular Ejection Fraction in Patients with Heart Failure
    Motoki, Hirohiko
    Borowski, Allen G.
    Shrestha, Kevin
    Hu, Bo
    Kusunose, Kenya
    Troughton, Richard W.
    Tang, W. H. Wilson
    Klein, Allan L.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (07) : 726 - 732
  • [24] Naderi Nasim, 2013, Congest Heart Fail, V19, P116, DOI 10.1111/chf.12009
  • [25] Anatomically oriented right ventricular volume measurements with dynamic three-dimensional echocardiography validated by 3-tesla magnetic resonance imaging
    Niemann, Petra S.
    Pinho, Luiz
    Balbach, Thomas
    Galuschky, Christian
    Blankenhagen, Michael
    Silberbach, Michael
    Broberg, Craig
    Jerosch-Herold, Michael
    Sahn, David J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (17) : 1668 - 1676
  • [26] AUTOMATED ECHOCARDIOGRAPHIC MEASURES OF RIGHT-VENTRICULAR AREA AS AN INDEX OF VOLUME AND END-SYSTOLIC PRESSURE-AREA RELATIONS TO ASSESS RIGHT-VENTRICULAR FUNCTION
    OE, M
    GORCSAN, J
    MANDARINO, WA
    KAWAI, A
    GRIFFITH, BP
    KORMOS, RL
    [J]. CIRCULATION, 1995, 92 (04) : 1026 - 1033
  • [27] Longitudinal Assessment of Right Ventricular Myocardial Strain in Relation to Transplant-Free Survival in Children with Idiopathic Pulmonary Hypertension
    Okumura, Kenichi
    Humpl, Tilman
    Dragulescu, Andreea
    Mertens, Luc
    Friedberg, Mark K.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (12) : 1344 - 1351
  • [28] ONLINE ASSESSMENT OF VENTRICULAR-FUNCTION BY AUTOMATIC BOUNDARY DETECTION AND ULTRASONIC BACKSCATTER IMAGING
    PEREZ, JE
    WAGGONER, AD
    BARZILAI, B
    MELTON, HE
    MILLER, JG
    SOBEL, BE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) : 313 - 320
  • [29] Regional Right Ventricular Strain Pattern in Patients with Acute Pulmonary Embolism
    Platz, Elke
    Hassanein, Amira H.
    Shah, Amil
    Goldhaber, Samuel Z.
    Solomon, Scott D.
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (04): : 464 - 470
  • [30] Poliacikova P, 2013, J INVASIVE CARDIOL, V25, P142