Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty

被引:27
作者
Kutzner, Karl Philipp [1 ]
Pfeil, Joachim [1 ]
机构
[1] St Josefs Hosp Wiesbaden, Dept Orthopaed Surg & Traumatol, Wiesbaden, Germany
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2018年 / 132期
关键词
Total hip arthroplasty; short stem; calcar-guided; operation technique; stem alignment; positioning; implantation;
D O I
10.3791/56905
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Bone- and soft-tissue sparing short stems are increasingly used in total hip arthroplasty (THA). However, there are a large variety of models of short stems, differing in design and function. Calcar-guided short stems provide an anatomical curvature in the medial calcar region, thus, positioning is done individually alongside the calcar in the "round-the-corner" technique. Depending on the level of the neck's osteotomy, stems can be aligned individually in a large bandwidth of varus-and valgus anatomies. This differs from conventional total hip arthroplasty and potentially includes a severe learning curve. Given that a great variety of caput-collum-diaphyseal (CCD)-angles can be retained, the reconstruction of femoro-acetabular offsets can be achieved precisely. However, particularly extensive varus-and valgus positioning has raised concerns in regard to stability and bone remodeling. The purpose of the present manuscript is to showcase the implantation technique in calcarguided short-stem THA and to summarize short-term clinical and radiological results.
引用
收藏
页数:11
相关论文
共 19 条
[1]  
Anderl C., 2015, JATROS ORTHOPADIE RH
[2]   Reconstructed hip joint position and abductor muscle strength after total hip arthroplasty [J].
Asayama, I ;
Chamnongkich, S ;
Simpson, KJ ;
Kinsey, TL ;
Mahoney, OM .
JOURNAL OF ARTHROPLASTY, 2005, 20 (04) :414-420
[3]   Primary stability and strain distribution of cementless hip stems as a function of implant design [J].
Bieger, Ralf ;
Ignatius, Anita ;
Decking, Ralf ;
Claes, Lutz ;
Reichel, Heiko ;
Duerselen, Lutz .
CLINICAL BIOMECHANICS, 2012, 27 (02) :158-164
[4]  
Hochreiter J., 2016, INT ORTHOP, P1
[5]   Comparison between preoperative digital planning and postoperative outcomes in 197 hip endoprosthesis cases using short stem prostheses [J].
Hoehle, Philip ;
Schroeder, Simon M. ;
Pfeil, Joachim .
CLINICAL BIOMECHANICS, 2015, 30 (01) :46-52
[6]  
Jerosch J., 2017, KURZSCHAFTENDOPROTHE
[7]  
KOVACEVIC MP, 2014, OUP, V10, P456, DOI DOI 10.3238/0UP.2014.0456-0461
[8]  
Kutzner K.P., 2016, ARCH ORTHOP TRAUMA S, P431
[9]  
Kutzner K. P., 2017, OPER ORTHOP TRAUMATO
[10]  
Kutzner K. P., 2014, INT ORTHOP