Continuous-Flow Left Ventricular Assist Device Therapy in Patients With Preoperative Hepatic Failure: Are We Pushing the Limits Too Far?

被引:13
作者
Weymann, Alexander [1 ,2 ]
Patil, Nikhil P. [1 ]
Sabashnikov, Anton [1 ,3 ]
Mohite, Phrashant N. [1 ]
Saez, Diana Garcia [1 ]
Bireta, Christian [4 ]
Wahlers, Thorsten [3 ]
Karck, Matthias [2 ]
Kallenbach, Klaus [2 ]
Ruhparwar, Arjang [2 ]
Fatullayev, Javid [1 ,3 ]
Amrani, Mohamed [1 ]
De Robertis, Fabio [1 ]
Bahrami, Toufan [1 ]
Popov, Aron-Frederik [1 ]
Simon, Andre R. [1 ]
机构
[1] Royal Brompton & Harefield NHS Fdn Trust, Dept Cardiothorac Transplantat & Mech Circulatory, London, England
[2] Heidelberg Univ, Ctr Heart, Dept Cardiac Surg, Heidelberg, Germany
[3] Univ Hosp Cologne, Dept Cardiothorac Surg, Cologne, Germany
[4] Univ Hosp Gottingen, Dept Thorac & Cardiovasc Surg, Gottingen, Germany
关键词
Continuous-flow left ventricular assist device; Bridge-to-transplantation; Bridge-to-recovery; Hepatic failure; End-organ dysfunction; LIVER-DISEASE SCORE; HEART-FAILURE; ADVERSE EVENTS; MELD-XI; MODEL; IMPLANTATION; PREDICTOR; MORTALITY; SURVIVAL; OUTCOMES;
D O I
10.1111/aor.12375
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to evaluate the effects and outcome of continuous-flow left ventricular assist device (cf-LVAD) therapy in patients with preoperative acute hepatic failure. The study design was a retrospective review of prospectively collected data. Included were 42 patients who underwent cf-LVAD implantation (64.3% HeartMate II, 35.7% HeartWare) between July 2007 and May 2013 with preoperative hepatic failure defined as elevation of greater than or equal to two liver function parameters above twice the upper normal range. Mean patient age was 35 +/- 12.5 years, comprising 23.8% females. Dilated cardiomyopathy was present in 92.9% of patients (left ventricular ejection fraction 17.3 +/- 5.9%). Mean support duration was 511 +/- 512 days (range: 2-1996 days). Mean preoperative laboratory parameters for blood urea nitrogen, serum creatinine, total bilirubin, and alanine aminotransferase were 9.5 +/- 5.4 mg/dL, 110.3 +/- 42.8 mu mol/L, 51.7 +/- 38.3 mmol/L, and 242.1 +/- 268.6 U/L, respectively. All parameters decreased significantly 1 month postoperatively. The mean preoperative modified Model for Endstage Liver Disease excluding international normalized ratio score was 16.03 +/- 5.57, which improved significantly after cf-LVAD implantation to 10.62 +/- 5.66 (P < 0.001) at 7 days and 5.83 +/- 4.98 (P < 0.001) at 30 days postoperatively. One-year and 5-year survival was 75.9 and 48.1%, respectively. 21.4% of the patients underwent LVAD explantation for myocardial recovery, 16.7% were successfully transplanted, and 7.1% underwent LVAD exchange for device failure over the follow-up period. Patients with preexisting acute hepatic failure are reasonable candidates for cf-LVAD implantation, with excellent rates of recovery and survival, suggesting that cf-LVAD therapy should not be denied to patients merely on grounds of "preoperative elevated liver enzymes/hepatopathy."
引用
收藏
页码:336 / 342
页数:7
相关论文
共 50 条
[31]   Infectious complications after pulsatile-flow and continuous-flow left ventricular assist device implantation [J].
Schaffer, Justin M. ;
Allen, Jeremiah G. ;
Weiss, Eric S. ;
Arnaoutakis, George J. ;
Patel, Nishant D. ;
Russell, Stuart D. ;
Shah, Ashish S. ;
Conte, John V. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (02) :164-174
[32]   Durability and clinical impact of tricuspid valve procedures in patients receiving a continuous-flow left ventricular assist device [J].
Han, Jiho ;
Takeda, Koji ;
Takayama, Hiroo ;
Kurlansky, Paul A. ;
Mauro, Christine M. ;
Colombo, Paolo C. ;
Yuzefpolskaya, Melana ;
Fukuhara, Shinichi ;
Truby, Lauren K. ;
Topkara, Veli K. ;
Garan, Arthur R. ;
Mancini, Donna M. ;
Naka, Yoshifumi .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (02) :520-U357
[33]   Outcomes in Patients with Severe Preexisting Renal Dysfunction After Continuous-Flow Left Ventricular Assist Device Implantation [J].
Raichlin, Eugenia ;
Baibhav, Bipul ;
Lowes, Brian D. ;
Zolty, Ronald ;
Lyden, Elizabeth R. ;
Vongooru, Hareprasad R. ;
Sidique, Alem ;
Moulton, Michael J. ;
Um, John Y. .
ASAIO JOURNAL, 2016, 62 (03) :261-267
[34]   Predicting Right Ventricular Failure in the Modern, Continuous Flow Left Ventricular Assist Device Era [J].
Atluri, Pavan ;
Goldstone, Andrew B. ;
Fairman, Alex S. ;
MacArthur, John W. ;
Shudo, Yasuhiro ;
Cohen, Jeffrey E. ;
Acker, Alexandra L. ;
Hiesinger, William ;
Howard, Jessica L. ;
Acker, Michael A. ;
Woo, Y. Joseph .
ANNALS OF THORACIC SURGERY, 2013, 96 (03) :857-864
[35]   The Successful Implantation of Continuous-Flow Left Ventricular Assist Device as a Destination Therapy in Korea: Echocardiographic Assessment [J].
Lee, Ga Yeon ;
Park, Sung-Ji ;
Kim, Sujin ;
Choi, Namgyung ;
Jeong, Dong Seop ;
Jeon, Eun-Seok ;
Lee, Young Tak .
JOURNAL OF KOREAN MEDICAL SCIENCE, 2014, 29 (01) :137-140
[36]   Device thrombosis in HeartMate II continuous-flow Left ventricular assist devices: A multifactorial phenomenon [J].
Uriel, Nir ;
Han, Jason ;
Morrison, Kerry A. ;
Nahumi, Nadav ;
Yuzefpolskaya, Melana ;
Garan, Arthur R. ;
Duong, Jimmy ;
Colombo, Paolo C. ;
Takayama, Hiroo ;
Thomas, Sunu ;
Naka, Yoshifumi ;
Jorde, Ulrich P. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (01) :51-59
[37]   Melding a High-Risk Patient for Continuous Flow Left Ventricular Assist Device into a Low-Risk Patient [J].
Amione-Guerra, Javier ;
Cruz-Solbes, Ana S. ;
Bonilla, Hilda Gonzalez ;
Estep, Jerry D. ;
Guha, Ashrith ;
Bhimaraj, Arvind ;
Suarez, Erik E. ;
Bruckner, Brian A. ;
Torre-Amione, Guillermo ;
Park, Myung H. ;
Trachtenberg, Barry H. .
ASAIO JOURNAL, 2017, 63 (06) :704-712
[38]   Clinical characteristics and outcomes of patients with ventricular arrhythmias after continuous-flow left ventricular assist device implant [J].
Gulletta, Simone ;
Scandroglio, Anna Mara ;
Pannone, Luigi ;
Falasconi, Giulio ;
Melisurgo, Giulio ;
Ajello, Silvia ;
D'Angelo, Giuseppe ;
Gigli, Lorenzo ;
Lipartiti, Felicia ;
Agricola, Eustachio ;
Lapenna, Elisabetta ;
Castiglioni, Alessandro ;
De Bonis, Michele ;
Landoni, Giovanni ;
Della Bella, Paolo ;
Zangrillo, Alberto ;
Vergara, Pasquale .
ARTIFICIAL ORGANS, 2022, 46 (08) :1608-1615
[39]   Implantable Cardioverter Defibrillators and Survival in Continuous-Flow Left Ventricular Assist Device Patients [J].
Kutyifa, Valentina ;
Fernandez, Genaro ;
Sherazi, Saadia ;
Aktas, Mehmet ;
Huang, David ;
McNitt, Scott ;
Papernov, Anna ;
Wang, Meng ;
Massey, H. Todd ;
Chen, Leway ;
Alexis, Jeffrey D. .
ASAIO JOURNAL, 2019, 65 (01) :49-53
[40]   Ventricular arrhythmias following continuous-flow left ventricular assist device implantation: A systematic review [J].
Gordon, Jonathan S. ;
Maynes, Elizabeth J. ;
Choi, Jae Hwan ;
Wood, Chelsey T. ;
Weber, Matthew P. ;
Morris, Rohinton J. ;
Massey, H. Todd ;
Tchantchaleishvili, Vakhtang .
ARTIFICIAL ORGANS, 2020, 44 (08) :E313-E325