Characterization and analysis of thermal denaturation of antibodies by size exclusion high-performance liquid chromatography with quadruple detection

被引:59
作者
Hartmann, WK [1 ]
Saptharishi, N [1 ]
Yang, XY [1 ]
Mitra, G [1 ]
Soman, G [1 ]
机构
[1] SAIC Frederick Inc, Bioanalyt Dev Lab, Biopharmaceut Dev Program, Frederick, MD 21702 USA
关键词
online SE-HPLC; light scattering; refractometry; intrinsic viscosity; protein aggregation kinetics; stability; thermal denaturation;
D O I
10.1016/j.ab.2003.10.031
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Size exclusion chromatography (SEC) coupled with online light scattering, viscometry, refractometry, and UV-visible spectroscopy provides a very powerful tool for studying protein size, shape, and aggregation. This technique can be used to determine the molecular weight of the component peaks independent of the retention times in the SEC column and simultaneously measure the hydrodynamic radius and polydispersity of the protein. We applied this technology by coupling an Agilent Chernstation high-performance liquid chromatography system with a diode array UV-visible detector and a Viscotek 300 EZ Pro triple detector (combination of a light scattering detector, refractometer, and differential pressure viscometer) to characterize and compare the molecular properties of a number of monoclonal antibodies. Our studies reveal that different monoclonal immunoglobulin Gs (IgGs) and chimeric IgGs show slightly different retention times and therefore different molecular weights in gel filtration analysis. However, when they are analyzed by light scattering, refractometry, and viscometry, different IgGs have comparable molecular weight, molecular homogeneity (polydispersity), and size. Gel filtration coupled with UV or refractive index detection suggests that antibodies purified and formulated for preclinical and clinical development are more than 95% monomer with little or no detectable soluble aggregates. Light scattering measurements showed the presence of trace amounts of soluble aggregate in all the IgG preparations. The different IgG molecules showed different susceptibility to heat and pH. One of the murine antibodies was considerably less stable than the others at 55 degreesC. The application of this powerful technology for the characterization of monoclonal antibodies of therapeutic potential is discussed. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:227 / 239
页数:13
相关论文
共 54 条
[1]   Determination of carbohydrate contents from excess light scattering [J].
Arakawa, T ;
Wen, J .
ANALYTICAL BIOCHEMISTRY, 2001, 299 (02) :158-161
[2]   Studies of the hydrodynamic volume changes that occur during refolding of lysozyme using size-exclusion chromatography [J].
Batas, B ;
Jones, HR ;
Chaudhuri, JB .
JOURNAL OF CHROMATOGRAPHY A, 1997, 766 (1-2) :109-119
[3]  
Bloomfield VA, 2000, BIOPOLYMERS, V54, P168, DOI 10.1002/1097-0282(200009)54:3<168::AID-BIP20>3.0.CO
[4]  
2-9
[5]  
Bohidar HB, 1998, BIOPOLYMERS, V45, P1
[6]   Thermal stability studies of immunoglobulins using capillary isoelectric focusing and capillary zone electrophoretic methods [J].
Dai, HJ ;
Krull, IS .
JOURNAL OF CHROMATOGRAPHY A, 1998, 807 (01) :121-128
[7]   PRACTICAL ONLINE DETERMINATION OF BIOPOLYMER MOLECULAR-WEIGHTS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CLASSICAL LIGHT-SCATTERING DETECTION [J].
DOLLINGER, G ;
CUNICO, B ;
KUNITANI, M ;
JOHNSON, D ;
JONES, R .
JOURNAL OF CHROMATOGRAPHY, 1992, 592 (1-2) :215-228
[8]   ANALYSIS OF PROTEIN DENATURATION BY HIGH-PERFORMANCE CONTINUOUS DIFFERENTIAL VISCOMETRY [J].
DUTTA, PK ;
HAMMONS, K ;
WILLIBEY, B ;
HANEY, MA .
JOURNAL OF CHROMATOGRAPHY, 1991, 536 (1-2) :113-121
[9]  
FASMAN GD, 1989, CRC HDB BIOCH MOL BI, V2
[10]   TREATMENT OF INTRINSIC VISCOSITIES [J].
FLORY, PJ ;
FOX, TG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1951, 73 (05) :1904-1908