Endoscopic removal and trimming of distal self-expandable metallic biliary stents

被引:27
作者
Ishii, Kentaro [1 ]
Itoi, Takao
Sofuni, Atsushi
Itokawa, Fumihide
Tsuchiya, Takayoshi
Kurihara, Toshio
Tsuji, Shujiro
Ikeuchi, Nobuhito
Umeda, Junko
Moriyasu, Fuminori
Tsuchida, Akihiko [2 ]
机构
[1] Tokyo Med Univ, Dept Gastroenterol & Hepatol, Shinjuku Ku, 6-7-1 Nishishinjuku, Tokyo 1600023, Japan
[2] Tokyo Med Univ, Dept Surg 3, Tokyo 1600023, Japan
关键词
Self-expandable metallic stent; Endoscopic biliary stenting; Endoscopic stent removal; Endoscopic stent trimming; COMMON BILE-DUCT; ARGON PLASMA COAGULATION; STRICTURES; OBSTRUCTION; WALLSTENTS; MANAGEMENT; PLACEMENT; TRIAL; VIDEO;
D O I
10.3748/wjg.v17.i21.2652
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM: To evaluate the efficacy and safety of endoscopic removal and trimming of self-expandable metallic stents (SEMS). METHODS: All SEMS had been placed for distal biliary strictures. Twenty-seven endoscopic procedures were performed in 19 patients in whom SEMS (one uncovered and 18 covered) removal had been attempted, and 8 patients in whom stent trimming using argon plasma coagulation (APC) had been attempted at Tokyo Medical University Hospital. The APC settings were: voltage 60-80 W and gas flow at 1.5 L/min. RESULTS: The mean stent indwelling period for all patients in whom stent removal had been attempted was 113.7 +/- 77.6 d (range, 8-280 d). Of the 19 patients in whom removal of the SEMS had been attempted, the procedure was successful in 14 (73.7%) without procedure-related adverse events. The indwelling period in the stent removable group was shorter than that in the unremovable group (94.9 +/- 71.5 d vs 166.2 +/- 76.2 d, P = 0.08). Stent trimming was successful for all patients with one minor adverse event consisting of self-limited hemorrhage. Trimming time ranged from 11 to 16 min. CONCLUSION: Although further investigations on larger numbers of cases are necessary to accumulate evidence, the present data suggested that stent removal and stent trimming is feasible and effective for stent-related complications. (C) 2011 Baishideng. All rights reserved.
引用
收藏
页码:2652 / 2657
页数:6
相关论文
共 50 条
[1]   Endoscopic removal and trimming of distal self-expandable metallic biliary stents [J].
Kentaro Ishii ;
Takao Itoi ;
Atsushi Sofuni ;
Fumihide Itokawa ;
Takayoshi Tsuchiya ;
Toshio Kurihara ;
Shujiro Tsuji ;
Nobuhito Ikeuchi ;
Junko Umeda ;
Fuminori Moriyasu ;
Akihiko Tsuchida .
World Journal of Gastroenterology, 2011, 17 (21) :2652-2657
[2]   Superiority of Self-Expandable Metallic Stents Over Plastic Stents in Treatment of Malignant Distal Biliary Strictures [J].
Jang, Sunguk ;
Stevens, Tyler ;
Parsi, Mansour A. ;
Bhatt, Amit ;
Kichler, Adam ;
Vargo, John J. .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2022, 20 (02) :E182-E195
[3]   Endoscopic removal of self-expandable metal stents from the esophagus [J].
van Heel, Nicoline C. M. ;
Haringsma, Jelle ;
Wijnhoven, Bas P. L. ;
Kuipers, Ernst J. .
GASTROINTESTINAL ENDOSCOPY, 2011, 74 (01) :44-50
[4]   Measurement of radial and axial forces of biliary self-expandable metallic stents [J].
Isayama, Hiroyuki ;
Nakai, Yousuke ;
Toyokawa, Yoshihide ;
Togawa, Osamu ;
Gon, Chimyon ;
Ito, Yukiko ;
Yashima, Yoko ;
Yagioka, Hiroshi ;
Kogure, Hirofumi ;
Sasaki, Takashi ;
Arizumi, Toshihiko ;
Matsubara, Saburo ;
Yamamoto, Natsuyo ;
Sasahira, Naoki ;
Hirano, Kenji ;
Tsujino, Takeshi ;
Toda, Nobuo ;
Tada, Minoru ;
Kawabe, Takao ;
Omata, Masao .
GASTROINTESTINAL ENDOSCOPY, 2009, 70 (01) :37-44
[5]   Management of dysfunctional covered self-expandable metallic stents in patients with malignant distal biliary obstruction [J].
Togawa, Osamu ;
Isayama, Hiroyuki ;
Tsujino, Takeshi ;
Nakai, Yousuke ;
Kogure, Hirofumi ;
Hamada, Tsuyoshi ;
Sasaki, Takashi ;
Yashima, Yoko ;
Yagioka, Hiroshi ;
Arizumi, Toshihiko ;
Ito, Yukiko ;
Matsubara, Saburo ;
Yamamoto, Natsuyo ;
Sasahira, Naoki ;
Hirano, Kenji ;
Toda, Nobuo ;
Tada, Minoru ;
Koike, Kazuhiko .
JOURNAL OF GASTROENTEROLOGY, 2013, 48 (11) :1300-1307
[6]   Endoscopic removal of laser-cut covered self-expandable metallic biliary stents: A report of six cases [J].
Tanisaka, Yuki ;
Ryozawa, Shomei ;
Kobayashi, Masanori ;
Harada, Maiko ;
Kobatake, Tsutomu ;
Omiya, Kumiko ;
Iwano, Hirotoshi ;
Arai, Shin ;
Nonaka, Kouichi ;
Mashimo, Yumi .
MOLECULAR AND CLINICAL ONCOLOGY, 2018, 8 (02) :269-273
[7]   Self-expandable metallic stents vs. plastic stents for endoscopic biliary drainage in hepatocellular carcinoma [J].
Chung, Kwang Hyun ;
Lee, Sang Hyub ;
Park, Jin Myung ;
Lee, Jae Min ;
Ahn, Dong-Won ;
Ryu, Ji Kon ;
Kim, Yong-Tae .
ENDOSCOPY, 2015, 47 (06) :509-517
[8]   The Dramatic Haemostatic Effect of Covered Self-expandable Metallic Stents for Duodenal and Biliary Bleeding [J].
Sugimoto, Mitsuru ;
Takagi, Tadayuki ;
Suzuki, Rei ;
Konno, Naoki ;
Asama, Hiroyuki ;
Sato, Yuki ;
Irie, Hiroki ;
Nakamura, Jun ;
Takasumi, Mika ;
Hashimoto, Minami ;
Kato, Tsunetaka ;
Kobashi, Ryoichiro ;
Hikichi, Takuto ;
Ohira, Hiromasa .
INTERNAL MEDICINE, 2021, 60 (06) :883-889
[9]   No Benefit of Endoscopic Sphincterotomy Before Biliary Placement of Self-Expandable Metal Stents for Unresectable Pancreatic Cancer [J].
Hayashi, Tsuyoshi ;
Kawakami, Hiroshi ;
Osanai, Manabu ;
Ishiwatari, Hirotoshi ;
Naruse, Hirohito ;
Hisai, Hiroyuki ;
Yanagawa, Nobuyuki ;
Kaneto, Hiroyuki ;
Koizumi, Kazuya ;
Sakurai, Tamaki ;
Sonoda, Tomoko .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2015, 13 (06) :1151-+
[10]   Fully-covered, self-expandable metal stents (CSEMS) in malignant distal biliary strictures: Mid-term evaluation [J].
Bakhru, Mihir ;
Ho, Henry C. ;
Gohil, Vishal ;
Wang, Andrew Y. ;
Ellen, Kristi ;
Sauer, Bryan G. ;
Shami, Vanessa M. ;
Kahaleh, Michel .
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2011, 26 (06) :1022-1027