Endoscopic removal and trimming of distal self-expandable metallic biliary stents

被引:27
|
作者
Ishii, Kentaro [1 ]
Itoi, Takao
Sofuni, Atsushi
Itokawa, Fumihide
Tsuchiya, Takayoshi
Kurihara, Toshio
Tsuji, Shujiro
Ikeuchi, Nobuhito
Umeda, Junko
Moriyasu, Fuminori
Tsuchida, Akihiko [2 ]
机构
[1] Tokyo Med Univ, Dept Gastroenterol & Hepatol, Shinjuku Ku, 6-7-1 Nishishinjuku, Tokyo 1600023, Japan
[2] Tokyo Med Univ, Dept Surg 3, Tokyo 1600023, Japan
关键词
Self-expandable metallic stent; Endoscopic biliary stenting; Endoscopic stent removal; Endoscopic stent trimming; COMMON BILE-DUCT; ARGON PLASMA COAGULATION; STRICTURES; OBSTRUCTION; WALLSTENTS; MANAGEMENT; PLACEMENT; TRIAL; VIDEO;
D O I
10.3748/wjg.v17.i21.2652
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM: To evaluate the efficacy and safety of endoscopic removal and trimming of self-expandable metallic stents (SEMS). METHODS: All SEMS had been placed for distal biliary strictures. Twenty-seven endoscopic procedures were performed in 19 patients in whom SEMS (one uncovered and 18 covered) removal had been attempted, and 8 patients in whom stent trimming using argon plasma coagulation (APC) had been attempted at Tokyo Medical University Hospital. The APC settings were: voltage 60-80 W and gas flow at 1.5 L/min. RESULTS: The mean stent indwelling period for all patients in whom stent removal had been attempted was 113.7 +/- 77.6 d (range, 8-280 d). Of the 19 patients in whom removal of the SEMS had been attempted, the procedure was successful in 14 (73.7%) without procedure-related adverse events. The indwelling period in the stent removable group was shorter than that in the unremovable group (94.9 +/- 71.5 d vs 166.2 +/- 76.2 d, P = 0.08). Stent trimming was successful for all patients with one minor adverse event consisting of self-limited hemorrhage. Trimming time ranged from 11 to 16 min. CONCLUSION: Although further investigations on larger numbers of cases are necessary to accumulate evidence, the present data suggested that stent removal and stent trimming is feasible and effective for stent-related complications. (C) 2011 Baishideng. All rights reserved.
引用
收藏
页码:2652 / 2657
页数:6
相关论文
共 50 条
  • [1] Endoscopic removal and trimming of distal self-expandable metallic biliary stents
    Kentaro Ishii
    Takao Itoi
    Atsushi Sofuni
    Fumihide Itokawa
    Takayoshi Tsuchiya
    Toshio Kurihara
    Shujiro Tsuji
    Nobuhito Ikeuchi
    Junko Umeda
    Fuminori Moriyasu
    Akihiko Tsuchida
    World Journal of Gastroenterology, 2011, 17 (21) : 2652 - 2657
  • [2] Superiority of Self-Expandable Metallic Stents Over Plastic Stents in Treatment of Malignant Distal Biliary Strictures
    Jang, Sunguk
    Stevens, Tyler
    Parsi, Mansour A.
    Bhatt, Amit
    Kichler, Adam
    Vargo, John J.
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2022, 20 (02) : E182 - E195
  • [3] Endoscopic removal of self-expandable metal stents from the esophagus
    van Heel, Nicoline C. M.
    Haringsma, Jelle
    Wijnhoven, Bas P. L.
    Kuipers, Ernst J.
    GASTROINTESTINAL ENDOSCOPY, 2011, 74 (01) : 44 - 50
  • [4] Measurement of radial and axial forces of biliary self-expandable metallic stents
    Isayama, Hiroyuki
    Nakai, Yousuke
    Toyokawa, Yoshihide
    Togawa, Osamu
    Gon, Chimyon
    Ito, Yukiko
    Yashima, Yoko
    Yagioka, Hiroshi
    Kogure, Hirofumi
    Sasaki, Takashi
    Arizumi, Toshihiko
    Matsubara, Saburo
    Yamamoto, Natsuyo
    Sasahira, Naoki
    Hirano, Kenji
    Tsujino, Takeshi
    Toda, Nobuo
    Tada, Minoru
    Kawabe, Takao
    Omata, Masao
    GASTROINTESTINAL ENDOSCOPY, 2009, 70 (01) : 37 - 44
  • [5] Management of dysfunctional covered self-expandable metallic stents in patients with malignant distal biliary obstruction
    Togawa, Osamu
    Isayama, Hiroyuki
    Tsujino, Takeshi
    Nakai, Yousuke
    Kogure, Hirofumi
    Hamada, Tsuyoshi
    Sasaki, Takashi
    Yashima, Yoko
    Yagioka, Hiroshi
    Arizumi, Toshihiko
    Ito, Yukiko
    Matsubara, Saburo
    Yamamoto, Natsuyo
    Sasahira, Naoki
    Hirano, Kenji
    Toda, Nobuo
    Tada, Minoru
    Koike, Kazuhiko
    JOURNAL OF GASTROENTEROLOGY, 2013, 48 (11) : 1300 - 1307
  • [6] Endoscopic removal of laser-cut covered self-expandable metallic biliary stents: A report of six cases
    Tanisaka, Yuki
    Ryozawa, Shomei
    Kobayashi, Masanori
    Harada, Maiko
    Kobatake, Tsutomu
    Omiya, Kumiko
    Iwano, Hirotoshi
    Arai, Shin
    Nonaka, Kouichi
    Mashimo, Yumi
    MOLECULAR AND CLINICAL ONCOLOGY, 2018, 8 (02) : 269 - 273
  • [7] Self-expandable metallic stents vs. plastic stents for endoscopic biliary drainage in hepatocellular carcinoma
    Chung, Kwang Hyun
    Lee, Sang Hyub
    Park, Jin Myung
    Lee, Jae Min
    Ahn, Dong-Won
    Ryu, Ji Kon
    Kim, Yong-Tae
    ENDOSCOPY, 2015, 47 (06) : 509 - 517
  • [8] The Dramatic Haemostatic Effect of Covered Self-expandable Metallic Stents for Duodenal and Biliary Bleeding
    Sugimoto, Mitsuru
    Takagi, Tadayuki
    Suzuki, Rei
    Konno, Naoki
    Asama, Hiroyuki
    Sato, Yuki
    Irie, Hiroki
    Nakamura, Jun
    Takasumi, Mika
    Hashimoto, Minami
    Kato, Tsunetaka
    Kobashi, Ryoichiro
    Hikichi, Takuto
    Ohira, Hiromasa
    INTERNAL MEDICINE, 2021, 60 (06) : 883 - 889
  • [9] No Benefit of Endoscopic Sphincterotomy Before Biliary Placement of Self-Expandable Metal Stents for Unresectable Pancreatic Cancer
    Hayashi, Tsuyoshi
    Kawakami, Hiroshi
    Osanai, Manabu
    Ishiwatari, Hirotoshi
    Naruse, Hirohito
    Hisai, Hiroyuki
    Yanagawa, Nobuyuki
    Kaneto, Hiroyuki
    Koizumi, Kazuya
    Sakurai, Tamaki
    Sonoda, Tomoko
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2015, 13 (06) : 1151 - +
  • [10] Fully-covered, self-expandable metal stents (CSEMS) in malignant distal biliary strictures: Mid-term evaluation
    Bakhru, Mihir
    Ho, Henry C.
    Gohil, Vishal
    Wang, Andrew Y.
    Ellen, Kristi
    Sauer, Bryan G.
    Shami, Vanessa M.
    Kahaleh, Michel
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2011, 26 (06) : 1022 - 1027