Robust principal component analysis-based four-dimensional computed tomography

被引:157
|
作者
Gao, Hao [1 ]
Cai, Jian-Feng [1 ]
Shen, Zuowei [2 ]
Zhao, Hongkai [3 ]
机构
[1] Univ Calif Los Angeles, Dept Math, Los Angeles, CA 90095 USA
[2] Natl Univ Singapore, Dept Math, Singapore 117543, Singapore
[3] Univ Calif Irvine, Dept Math, Irvine, CA 92697 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 11期
关键词
RADIATION-THERAPY; IMAGE-RESTORATION; DOSE REDUCTION; DATA-FIDELITY; CT; ALGORITHM; RECONSTRUCTION; REGULARIZATION; REGISTRATION; METHODOLOGY;
D O I
10.1088/0031-9155/56/11/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this paper for four-dimensional (4D) computed tomography (CT) is threefold. (1) A new spatiotemporal model is presented from the matrix perspective with the row dimension in space and the column dimension in time, namely the robust PCA (principal component analysis)-based 4D CT model. That is, instead of viewing the 4D object as a temporal collection of three-dimensional (3D) images and looking for local coherence in time or space independently, we perceive it as a mixture of low-rank matrix and sparse matrix to explore the maximum temporal coherence of the spatial structure among phases. Here the low-rank matrix corresponds to the 'background' or reference state, which is stationary over time or similar in structure; the sparse matrix stands for the 'motion' or time-varying component, e. g., heart motion in cardiac imaging, which is often either approximately sparse itself or can be sparsified in the proper basis. Besides 4D CT, this robust PCA-based 4D CT model should be applicable in other imaging problems for motion reduction or/and change detection with the least amount of data, such as multi-energy CT, cardiac MRI, and hyperspectral imaging. (2) A dynamic strategy for data acquisition, i.e. a temporally spiral scheme, is proposed that can potentially maintain similar reconstruction accuracy with far fewer projections of the data. The key point of this dynamic scheme is to reduce the total number of measurements, and hence the radiation dose, by acquiring complementary data in different phases while reducing redundant measurements of the common background structure. (3) An accurate, efficient, yet simple-to-implement algorithm based on the split Bregman method is developed for solving the model problem with sparse representation in tight frames.
引用
收藏
页码:3181 / 3198
页数:18
相关论文
共 50 条
  • [31] Four-dimensional computed tomography: Image formation and clinical protocol
    Rietzel, E
    Pan, TS
    Chen, GTY
    MEDICAL PHYSICS, 2005, 32 (04) : 874 - 889
  • [32] Commissioning a four-dimensional computed tomography system for clinical implementation
    Sasaki, D. K.
    Ingleby, H.
    Venkataraman, S.
    MEDICAL PHYSICS, 2009, 36 (09) : 4319 - 4320
  • [33] Robust principal component analysis-based coherency identification of generators with missing PMU measurements
    Qing, Xiangyun
    Wang, Shaobo
    Jia, Tinggang
    Niu, Yugang
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2016, 11 (01) : 36 - 42
  • [34] Utility of four-dimensional computed tomography for analysis of intrafractional and interfractional variation in lung volumes
    Rosen, Benjamin
    Starkschall, George
    Britton, Keith
    Mohan, Radhe
    Cox, James D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : 288 - 294
  • [35] Availability of a simplified lung ventilation imaging algorithm based on four-dimensional computed tomography
    Tian, Yuan
    Miao, Junjie
    Liu, Zhiqiang
    Huang, Peng
    Wang, Wenqin
    Wang, Xin
    Zhai, Yirui
    Wang, Jingbo
    Li, Minghui
    Ma, Pan
    Zhang, Ke
    Yan, Hui
    Dai, Jianrong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 53 - 58
  • [36] Four-dimensional computed tomography based assessment and analysis of lung tumor mobility during free breathing respiration
    Wang, Yan
    Bao, Yong
    He, Han
    Zhang, Li
    Fan, Wei
    Yu, Hong-bo
    Deng, Xiao-Wu
    Chen, Ming
    JOURNAL OF THORACIC ONCOLOGY, 2009, 4 (09) : S940 - S940
  • [37] Analysis of principal component analysis-based and fisher discriminant analysis-based face recognition algorithms
    Naz, Erum
    Farooq, Umar
    Naz, Tabbasum
    SECOND INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES 2006, PROCEEDINGS, 2006, : 121 - 127
  • [38] Principal Component Analysis-Based Visual Saliency Detection
    Yang, Bing
    Zhang, Xiaoyun
    Chen, Li
    Gao, Zhiyong
    IEEE TRANSACTIONS ON BROADCASTING, 2016, 62 (04) : 842 - 854
  • [39] Improvement in banding artefacts in four-dimensional computed tomography for radiotherapy planning
    Mori, Shinichiro
    Endo, Masahiro
    Asakura, Hiroshi
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (20): : 5231 - 5244
  • [40] Four-Dimensional Inverse Geometry Computed Tomography: Concept and Its Validation
    Kim, K.
    Kim, D.
    Kim, T.
    Kang, S.
    Cho, M.
    Shin, D.
    Suh, T.