Monitoring Strategic Hydraulic Infrastructures by Brillouin Distributed Fiber Optic Sensors

被引:13
作者
Bertulessi, Manuel [1 ]
Bignami, Daniele Fabrizio [2 ]
Boschini, Ilaria [1 ]
Brunero, Marco [3 ]
Ferrario, Maddalena [3 ]
Menduni, Giovanni [1 ]
Morosi, Jacopo [3 ]
Paganone, Egon Joseph [4 ]
Zambrini, Federica [1 ]
机构
[1] Politecn Milan, Civil & Environm Engn Dept, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
[2] Fdn Politecn Milano, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
[3] Cohaerentia Srl, Via Pinturicchio 5, I-20131 Milan, Italy
[4] CVA SpA, Via Stn 31, I-11024 Chatillon, Italy
关键词
structural health monitoring; hydraulic infrastructures; smart structures; flood risk management; non-structural risk prevention measures; Brillouin fiber optic distributed sensors; vibrating wire extensometers; strain monitoring; comparing sensing technologies; OF-THE-ART; STRAIN; LEVEE; LESSONS; DESIGN;
D O I
10.3390/w14020188
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We present a case study of a Structural Health Monitoring (SHM) hybrid system based on Brillouin Distributed Fiber Optic Sensors (D-FOS), Vibrating Wire (VW) extensometers and temperature probes for an existing historical water penstock bridge positioned in a mountain valley in Valle d'Aosta Region, Northwestern Italy. We assessed Brillouin D-FOS performances for this kind of infrastructure, characterized by a complex structural layout and located in a harsh environment. A comparison with the more traditional strain monitoring technology offered by VW strain gauges was performed. The D-FOS strain cable has been bonded to the concrete members using a polyurethane-base adhesive, ensuring a rigid strain transfer. The raw data from all sensors are interpolated on a unique general timestamp with hourly resolution. Strain data from D-FOS and VW strain gauges are then corrected from temperature effects and compared. Considering the inherent differences between the two monitoring technologies, results show a good overall matching between strain time series collected by D-FOS and VW sensors. Brillouin D-FOS proves to be a good solution in terms of performance and economic investment for SHM systems on complex infrastructures such as hydropower plants, which involve extensive geometry combined with the need for detailed and continuous strain monitoring.
引用
收藏
页数:17
相关论文
共 34 条
[1]   Mechanics of bond and interface shear transfer in optical fiber sensors [J].
Ansari, F ;
Libo, Y .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 1998, 124 (04) :385-394
[2]   Practical implementation of optical fiber sensors in civil structural health monitoring [J].
Ansari, Farhad .
JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2007, 18 (08) :879-889
[3]   RISK OF DAM FAILURE IN BENEFIT-COST-ANALYSIS [J].
BAECHER, GB ;
PATE, ME ;
DENEUFVILLE, R .
WATER RESOURCES RESEARCH, 1980, 16 (03) :449-456
[4]   Tensile and compressive strain measurement in the lab and field with the distributed Brillouin scattering sensor [J].
Bao, XY ;
DeMerchant, M ;
Brown, A ;
Bremner, T .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 2001, 19 (11) :1698-1704
[5]   A Review of Distributed Optical Fiber Sensors for Civil Engineering Applications [J].
Barrias, Antonio ;
Casas, Joan R. ;
Villalba, Sergi .
SENSORS, 2016, 16 (05)
[6]  
Bastianini F., 2007, E J EXHIBITION NONDE, P269
[7]   Optical Fiber Sensing Cables for Brillouin-Based Distributed Measurements [J].
Bastianini, Filippo ;
Di Sante, Raffaella ;
Falcetelli, Francesco ;
Marini, Diego ;
Bolognini, Gabriele .
SENSORS, 2019, 19 (23)
[8]   Conceptualization and Prototype of an Anti-Erosion Sensing Revetment for Levee Monitoring: Experimental Tests and Numerical Modeling [J].
Bertulessi, Manuel ;
Bignami, Daniele F. ;
Boschini, Ilaria ;
Chiarini, Andrea ;
Ferrario, Maddalena ;
Mazzon, Nicola ;
Menduni, Giovanni ;
Morosi, Jacopo ;
Zambrini, Federica .
WATER, 2020, 12 (11) :1-16
[9]   Structural health monitoring of civil infrastructure [J].
Brownjohn, J. M. W. .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2007, 365 (1851) :589-622
[10]  
Chen H.P., 2018, Structural Health Monitoring of Large Civil Engineering Structures