In-tube solid-phase microextraction coupled to liquid chromatography (in-tube SPME/LC) analysis of nontricyclic antidepressants in human plasma

被引:70
作者
Goncalves Silva, Bruno Jose [1 ]
Lancas, Fernando Mauro [2 ]
Costa Queiroz, Maria Eugenia [1 ]
机构
[1] Univ Sao Paulo, Dept Quim, Fac Filosofia Ciencias & Letras Ribeirao Preto, BR-14040901 Ribeirao Preto, SP, Brazil
[2] Univ Sao Paulo, Inst Quim Sao Carlos, BR-13560970 Sao Carlos, SP, Brazil
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2008年 / 862卷 / 1-2期
关键词
in-tube solid-phase microextraction; plasma samples; nontricyclic antidepressants;
D O I
10.1016/j.jchromb.2007.12.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive, selective, and reproducible in-tube solid-phase microextraction and liquid chromatographic (in-tube SPME/LC-UV) method for simultaneous determination of mirrazapine, citalopram, paroxetine, duloxetine, fluoxetine, and sertraline in human plasma was developed, validated and further applied to the analysis of plasma samples from elderly patients undergoing therapy with antidepressants. Important factors in the optimization of in-tube SPME efficiency are discussed, including the sample draw/eject volume, draw/eject cycle number, draw/eject flow-rate, sample pH, and influence of plasma proteins. The quantification limits of the in-tube SPME/LC method varied between 20 and 50 ng/mL, with a coefficient of variation lower than 10%. The response of the in-tube SPME/LC method for most of the drugs was linear over a dynamic range from 50 to 500 ng/mL, with correlation coefficients higher than 0.9985. The in-tube SPME/LC can be successfully used to analyze plasma samples from ageing patients undergoing therapy with nontricyclic antidepressants. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:181 / 188
页数:8
相关论文
共 23 条
[11]   Selective serotonin reuptake inhibitors in affective disorders - I. Basic pharmacology [J].
Goodnick, PJ ;
Goldstein, BJ .
JOURNAL OF PSYCHOPHARMACOLOGY, 1998, 12 (03) :S5-S20
[12]   Simultaneous determination of fluoxetine, citalopram, paroxetine, venlafaxine in plasma by high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI) [J].
He, J ;
Zhou, ZL ;
Li, HD .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 820 (01) :33-39
[13]   Rapid and sensitive method for the determination of sertraline in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS) [J].
Jain, DS ;
Sanyal, M ;
Subbaiah, G ;
Pande, UC ;
Shrivastav, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 829 (1-2) :69-74
[14]  
Jinno K, 2001, ELECTROPHORESIS, V22, P3785, DOI 10.1002/1522-2683(200109)22:17<3785::AID-ELPS3785>3.0.CO
[15]  
2-U
[17]  
Lanças FM, 2004, LC GC N AM, V22, P970
[18]   Microextraction of drugs [J].
Lord, H ;
Pawliszyn, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (01) :17-63
[19]  
Pawliszyn J., 1997, SOLID PHASE MICROEXT
[20]   Validation of chromatographic methods: Evaluation of detection and quantification limits in the determination of impurities in orneprazole [J].
Ribani, Marcelo ;
Collins, Carol H. ;
Bottoli, Carla B. G. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1156 (1-2) :201-205