Efficient scatter modelling for incorporation in maximum likelihood reconstruction

被引:25
作者
Hutton, BF
Baccarne, V
机构
[1] Westmead Hosp, Dept Med Phys, Sydney, NSW 2145, Australia
[2] Westmead Hosp, Dept Med Nucl & Ultrasound, Sydney, NSW 2145, Australia
关键词
single-photon emission tomography; scatter correction; maximum likelihood reconstruction; Monte Carlo simulation;
D O I
10.1007/s002590050345
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Definition of a simplified model of scatter which can be incorporated in maximum likelihood reconstruction for single-photon emission tomography (SPET) continues to be appealing; however, implementation must be efficient for it to be clinically applicable. In this paper an efficient algorithm for scatter estimation is described in which the spatial scatter distribution is implemented as a spatially invariant convolution for points of constant depth in tissue. The scatter estimate is weighted by a space-dependent build-up factor based on the measured attenuation in tissue, Monte Carlo simulation of a realistic thorax phantom was used to validate this approach. Further efficiency was introduced by estimating scatter once after a small number of iterations using the ordered subsets expectation maximisation (OSEM) reconstruction algorithm. The scatter estimate was incorporated as a constant term in subsequent iterations rather than modifying the scatter estimate each iteration. Monte Carlo simulation was used to demonstrate that the scatter estimate does not change significantly provided at least two iterations OSEM reconstruction, subset size 8, is used. Complete scatter-corrected reconstruction of 64 projections of 40x128 pixels was achieved in 38 min using a Sun Sparc20 computer.
引用
收藏
页码:1658 / 1665
页数:8
相关论文
共 24 条
  • [1] Deriving attenuation coefficients from 3D CT data for SPECT Monte Carlo simulations
    Baccarne, V
    Turzo, A
    Bizais, Y
    Farine, M
    [J]. PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 171 - 181
  • [2] Simultaneous emission transmission tomography using technetium-99m for both emission and transmission
    Barnden, LR
    Ong, PL
    Rowe, CC
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (11) : 1390 - 1397
  • [3] SPECT scatter modelling in non-uniform attenuating objects
    Beekman, FJ
    denHarder, JM
    Viergever, MA
    vanRijk, PP
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (06) : 1133 - 1142
  • [4] BEEKMAN FJ, 1993, IEEE T NUCL SCI, V40, P1308
  • [5] BOWSHER JE, 1991, J NUCL MED, V32, P1285
  • [6] SCATTER CORRECTION IN SCINTIGRAPHY - THE STATE-OF-THE-ART
    BUVAT, I
    BENALI, H
    TODDPOKROPEK, A
    DIPAOLA, R
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1994, 21 (07): : 675 - 694
  • [7] Frey E. C., 1997, Journal of Nuclear Medicine, V38, p88P
  • [8] PARAMETERIZATION OF THE SCATTER RESPONSE FUNCTION IN SPECT IMAGING USING MONTE-CARLO SIMULATION
    FREY, EC
    TSUI, BMW
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (03) : 1308 - 1315
  • [9] FREY EC, 1996, P IEEE MED IM C AN
  • [10] ACCELERATED IMAGE-RECONSTRUCTION USING ORDERED SUBSETS OF PROJECTION DATA
    HUDSON, HM
    LARKIN, RS
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (04) : 601 - 609