Cramer-Rao Lower Bound for Unbiased Estimators of Sampled Noisy Sine-Wave Parameters

被引:0
|
作者
Belega, Daniel [1 ]
Petri, Dario [2 ]
机构
[1] Univ Politehn Timisoara, Dept Measurements & Opt Elect, Timisoara 300223, Romania
[2] Univ Trento, Dept Ind Engn, I-38123 Trento, Italy
关键词
Parameter estimation; random noise; signal sampling; statistical analysis; uncertainty; 3-PARAMETER; ACCURACY; BIAS;
D O I
10.1109/TIM.2021.3122791
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, the Cramer-Rao lower bounds (CRLBs) for unbiased estimators of sampled real-valued sine-wave parameters are analyzed. Sine-wave frequency is assumed either known or unknown, and both coherent and noncoherent sampling conditions are considered. It is shown that the CRLBs coincide with the relationships widely used in the literature only when both coherent sampling occurs and the sine-wave frequency is known. In fact, when few sine-wave cycles are observed, errors associated with the widely used relationships may be significant. Approximate, but accurate and quite simple expressions for the CRLBs are also proposed in this article. All the derived expressions are verified through numerical results or computer simulations.
引用
收藏
页数:9
相关论文
共 25 条
  • [21] Cramer-Rao lower bound for single target tracking accuracy with coordinated turn maneuvers using range and bearing measurements
    Karan, M
    Lobbia, RN
    FUSION 2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE OF INFORMATION FUSION, VOLS 1 AND 2, 2003, : 911A - 918A
  • [22] Cramer-Rao Lower Bound Optimization for Hidden Moving Target Sensing via Multi-IRS-Aided Radar
    Esmaeilbeig, Zahra
    Mishra, Kumar Vijay
    Eamaz, Arian
    Soltanalian, Mojtaba
    IEEE SIGNAL PROCESSING LETTERS, 2022, 29 : 2422 - 2426
  • [23] Cramer-Rao Lower Bound for Point Based Image Registration With Heteroscedastic Error Model for Application in Single Molecule Microscopy
    Cohen, E. A. K.
    Kim, D.
    Ober, R. J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (12) : 2632 - 2644
  • [24] Cramer-Rao lower bound for single target tracking accuracy with coordinated turn maneuvers using range and bearing measurements
    Karan, M
    Lobbia, RN
    FUSION 2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE OF INFORMATION FUSION, VOLS 1 AND 2, 2003, : 911 - 918
  • [25] Optimizing Proton Stopping Power Ratio Prediction with Dual-Energy Cone-Beam CT Using the Cramer-Rao Lower Bound
    Leibold, David
    Schaart, Dennis R.
    Goorden, Marlies C.
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925