B-mode flow imaging of the carotid artery

被引:57
作者
Umemura, A [1 ]
Yamada, K [1 ]
机构
[1] Nagoya City Univ, Sch Med, Dept Neurosurg, Mizuho Ku, Nagoya, Aichi 4678601, Japan
关键词
carotid arteries; carotid stenosis; diagnostic imaging; ultrasonography;
D O I
10.1161/hs0901.095648
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-B-mode ultrasonography has been used to evaluate cervical carotid artery lesions. Recently, the technology for direct visualization of blood reflectors has made B-mode flow imaging (B-flow) possible without the limitations of Doppler technology. We evaluated the efficacy of B-flow in examining the cervical carotid artery. Methods-Sixty patients with ischemic cerebrovascular disease were examined. Conventional B-mode imaging and blood flow images by power Doppler imaging (PDI) and B-flow were obtained. Results-B-flow enabled simultaneous imaging of tissue and blood flow. Compared with PDI, B-flow provided higher spatial resolution and higher frame rate hemodynamic imaging. Consequently, a clear definition of the vessel lumen was L-h obtained even in the stenotic portion of the carotid artery. In evaluating the degree of carotid stenosis, B-flow measurement agreed with digital subtraction angiography as well as PDI measurement. In addition, bloodstream swirl at the site of wall ulceration or vascular elongation was observed. Conclusions-B-flow was prominent in visualizing hemodynamic flow and detection of stenotic lesion in the cervical carotid artery. Combined with conventional B-mode technique, B-flow seems to be useful in evaluating carotid stenosis.
引用
收藏
页码:2055 / 2057
页数:3
相关论文
共 10 条
[1]   Cerebrovascular disease assessed by color-flow and power Doppler ultrasonography - Comparison with digital subtraction angiography in internal carotid artery stenosis [J].
Griewing, B ;
Morgenstern, C ;
Driesner, F ;
Kallwellis, G ;
Walker, ML ;
Kessler, C .
STROKE, 1996, 27 (01) :95-100
[2]   ULTRASONIC EVALUATION OF EARLY CAROTID ATHEROSCLEROSIS [J].
HANDA, N ;
MATSUMOTO, M ;
MAEDA, H ;
HOUGAKU, H ;
OGAWA, S ;
FUKUNAGA, R ;
YONEDA, S ;
KIMURA, K ;
KAMADA, T .
STROKE, 1990, 21 (11) :1567-1572
[3]   Modality effects and the development of the word length effect in children [J].
Henry, LA ;
Turner, JE ;
Smith, PT ;
Leather, C .
MEMORY, 2000, 8 (01) :1-17
[4]   Validity of B-mode ultrasonographic findings in patients undergoing carotid endarterectomy in comparison with angiographic and clinicopathologic features [J].
Kagawa, R ;
Moritake, K ;
Shima, T ;
Okada, Y .
STROKE, 1996, 27 (04) :700-705
[5]   New application of B-flow sono-angiography in perinatology [J].
Pooh, RK .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 15 (02) :163-163
[6]   PROGNOSTIC VALUE AND REPRODUCIBILITY OF MEASUREMENTS OF CAROTID STENOSIS - A COMPARISON OF 3 METHODS ON 1001 ANGIOGRAMS [J].
ROTHWELL, PM ;
GIBSON, RJ ;
SLATTERY, J ;
WARLOW, CP .
STROKE, 1994, 25 (12) :2440-2444
[7]   Sonographic assessment of carotid artery stenosis - Comparison of power Doppler imaging and color Doppler flow imaging [J].
Steinke, W ;
Meairs, S ;
Ries, S ;
Hennerici, M .
STROKE, 1996, 27 (01) :91-94
[8]   Power Doppler imaging of carotid artery stenosis - Comparison with color Doppler flow imaging and angiography [J].
Steinke, W ;
Ries, S ;
Artemis, N ;
Schwartz, A ;
Hennerici, M .
STROKE, 1997, 28 (10) :1981-1987
[9]   SHEAR-INDUCED PLATELET-AGGREGATION IN CEREBRAL-ISCHEMIA [J].
UCHIYAMA, S ;
YAMAZAKI, M ;
MARUYAMA, S ;
HANDA, M ;
IKEDA, Y ;
FUKUYAMA, M ;
ITAGAKI, I .
STROKE, 1994, 25 (08) :1547-1551
[10]  
Weskott HP, 2000, ULTRASCHALL MED, V21, P59