Young's modulus in normal corners and the effect on applanation tonometry

被引:89
作者
Hamilton, Kirsten E. [1 ,2 ]
Pye, David C. [2 ]
机构
[1] Cardiff Univ, Sch Optometry & Vis Sci, Cardiff CF24 4LU, Wales
[2] Univ New S Wales, Sch Optometry & Vis Sci, Sydney, NSW, Australia
关键词
cornea; biomechanics; tonometry; Goldmann; applanation; intraocular pressure;
D O I
10.1097/OPX.0b013e3181783a70
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives. To determine the statistically normal range of corneal Young's modulus in young healthy eyes in vivo, and to establish if this variation has a clinically significant influence on intraocular pressure (IOP) measurement using applanation tonometry. Methods. Central corneal curvature, central corneal thickness (CCT), and applanation IOP (Goldmann tonometer) were measured using standard clinical techniques in one eye of 100 normal human subjects'(22.0 +/- 2.9 years) in vivo. The Orssengo-Pye algorithm was used to calculate the corneal Young's modulus of these experimental subjects, and to produce a theoretical model of potential errors in Goldmann applanation tonometry estimates of IOP due to variations of Young's modulus and CCT. Results. Corneal Young's modulus was 0.29 +/- 0.06 MPa [95% confidence interval (CI) 0.17 to 0.40 MPa]. According to the Orssengo-Pye model, the relationship between Young's modulus and the error in applanation IOP is linear; the slope was 23 mm Hg per MPa. An increase from the minimum to the maximum value of the calculated limits of agreement (95% CI) of Young's modulus caused a variation in applanation IOP of 5.35 mm Hg. The anticipated error at the extremes of the limits of agreement (95% CI) of CCT was similar at 4.67 mm Hg. Conclusion. Physiological variations in corneal Young's modulus may cause clinically significant errors in Goldmann applanation tonometry estimates of IOP.
引用
收藏
页码:445 / 450
页数:6
相关论文
共 31 条
[1]   BIOMECHANICAL PROPERTIES OF KERATOCONUS AND NORMAL CORNEAS [J].
ANDREASSEN, TT ;
SIMONSEN, AH ;
OXLUND, H .
EXPERIMENTAL EYE RESEARCH, 1980, 31 (04) :435-441
[2]   Constitutive laws for biomechanical modeling of refractive surgery [J].
Bryant, MR ;
McDonnell, PJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (04) :473-481
[3]  
Buzard K A, 1992, Refract Corneal Surg, V8, P127
[4]  
Daxer A, 1998, INVEST OPHTH VIS SCI, V39, P644
[5]   Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach [J].
Doughty, MJ ;
Zaman, ML .
SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) :367-408
[6]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
[7]   Assessment of corneal biomechanical properties and their variation with age [J].
Elsheikh, Ahmed ;
Wang, Defu ;
Brown, Michael ;
Rama, Paolo ;
Campanelli, Marino ;
Pye, David .
CURRENT EYE RESEARCH, 2007, 32 (01) :11-19
[8]   Evaluation of goldmann applanation tonometry using a nonlinear finite element ocular model [J].
Elsheikh, Ahmed ;
Wang, Defu ;
Kotecha, Aachal ;
Brown, Michael ;
Garway-Heath, David .
ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (10) :1628-1640
[9]  
Fung Y. C., 2013, BIOMECHANICS MECH PR
[10]  
Hjortdal JO, 1998, ACTA OPHTHALMOL SCAN, V76, P3