Amperometric determination of sympathomimetic drugs by flow injection analysis with a metallic copper electrode

被引:6
作者
Chicharro, M [1 ]
Zapardiel, A [1 ]
Bermejo, E [1 ]
Pérez, JA [1 ]
Hernández, L [1 ]
机构
[1] Univ Autonoma Madrid, Fac Ciencias, Dept Quim Analit & Anal Instrumental, E-28049 Madrid, Spain
关键词
copper electrode; copper; flow injection analysis; sympathomimetic drugs; norephedrine; ephedrine;
D O I
10.1016/S0003-2670(98)00656-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The detection and determination of sympathomimetic drugs in flow injection systems with an amperometric method based on a metallic copper wire electrode is described. The copper electrode is shown to give sensitive response toward sympathomimetic drugs, especially for norephedrine in flow injection analysis. The copper electrodes require no pretreatment except polishing before use. Furthermore, the copper working electrode shows stable response in such a system and the relative standard deviation is only 4.6% for 30 consecutive norephedrine injections at a 0.15 mM level. A detection limit of 10(-9) mol (0.15 mu g norephedrine) for a sample loop of 0.1 mi was obtained at a fixed potential of +0.6 V (vs. Ag/AgCl) in NaOH 0.1 M and a Bow rate of 2.0 ml/min. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 14 条
[1]  
Ateya Badr G., 1981, J. Electroanal. Chem, V117, P309, DOI [10.1016/S0022-0728(81)80091-5, DOI 10.1016/S0022-0728(81)80091-5]
[2]   THE PARTICIPATION OF INTERFACIAL HYDROUS OXIDE SPECIES IN SOME ANODIC REACTIONS AT COPPER ELECTRODES IN BASE [J].
BURKE, LD ;
RYAN, TG .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1990, 137 (05) :1358-1364
[3]   Potentiometric detection of aliphatic amines by flow injection analysis and ion-interaction chromatography with a metallic copper electrode [J].
Chen, ZL ;
Alexander, PW .
JOURNAL OF CHROMATOGRAPHY A, 1997, 758 (02) :227-233
[4]   DETERMINATION OF EPHEDRINE IN HUMAN URINE USING A GLASSY-CARBON ELECTRODE [J].
CHICHARRO, M ;
ZAPARDIEL, A ;
BERMEJO, E ;
PEREZ, JA ;
HERNANDEZ, L .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :361-368
[5]  
CHICHARRO M, 1995, ANALUSIS, V23, P131
[6]   EPHEDRINE DETERMINATION IN HUMAN URINE USING A CARBON-PASTE ELECTRODE MODIFIED WITH C-18 BONDED SILICA-GEL [J].
CHICHARRO, M ;
ZAPARDIEL, A ;
BERMEJO, E ;
PEREZ, JA ;
HERNANDEZ, L .
ANALYTICAL LETTERS, 1994, 27 (10) :1809-1831
[7]   DIRECT DETERMINATION OF EPHEDRINE ALKALOIDS AND EPINEPHRINE IN HUMAN URINE BY CAPILLARY ZONE ELECTROPHORESIS [J].
CHICHARRO, M ;
ZAPARDIEL, A ;
BERMEJO, E ;
PEREZLOPEZ, JA ;
HERNANDEZ, L .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (07) :1363-1381
[8]  
JONHSON DC, 1990, ANAL CHEM A, V589, P62
[9]   AMPEROMETRIC DETECTION OF AMINO-ACIDS WITH A PASSIVATED COPPER ELECTRODE [J].
KOK, WT ;
HANEKAMP, HB ;
BOS, P ;
FREI, RW .
ANALYTICA CHIMICA ACTA, 1982, 142 (OCT) :31-45
[10]   CONSTANT POTENTIAL AMPEROMETRIC DETECTION OF UNDERIVATIZED AMINO-ACIDS AND PEPTIDES AT A COPPER ELECTRODE [J].
LUO, PF ;
ZHANG, FZ ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1702-1707