Glycemic Variability Is Associated with Frequency of Blood Glucose Testing and Bolus: Post Hoc Analysis Results from the ProAct Study

被引:13
作者
Pfuetzner, Andreas [1 ]
Weissmann, Joerg [2 ]
Mougiakakou, Stavroula [3 ]
Daskalaki, Elena [3 ]
Weis, Norbert [2 ]
Ziegler, Ralph [4 ]
机构
[1] Diabet Ctr & Practice, Mainz, Germany
[2] Roche Diagnost Deutschland GmbH, Mannheim, Germany
[3] Univ Bern, Biomed Engn Res Ctr, ARTORG, Bern, Switzerland
[4] Diabet Clin Children & Adolescents, Munster, Germany
关键词
SUBCUTANEOUS INSULIN INFUSION; SEVERE HYPOGLYCEMIA; DIABETES-MELLITUS; METABOLIC-CONTROL; PUMP THERAPY; TYPE-1; ADOLESCENTS; QUALITY;
D O I
10.1089/dia.2014.0278
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The ProAct study has shown that a pump switch to the Accu-Chek((R)) Combo system (Roche Diagnostics Deutschland GmbH, Mannheim, Germany) in type 1 diabetes patients results in stable glycemic control with significant improvements in glycated hemoglobin (HbA1c) in patients with unsatisfactory baseline HbA1c and shorter pump usage time. Patients and Methods: In this post hoc analysis of the ProAct database, we investigated the glycemic control and glycemic variability at baseline by determination of several established parameters and scores (HbA1c, hypoglycemia frequency, J-score, Hypoglycemia and Hyperglycemia Indexes, and Index of Glycemic Control) in participants with different daily bolus and blood glucose measurement frequencies (less than four day, four or five per day, and more than five per day, in both cases). The data were derived from up to 299 patients (172 females, 127 males; age [mean +/- SD], 39.4 +/- 15.2 years; pump treatment duration, 7.0 +/- 5.2 years). Results: Participants with frequent glucose readings had better glycemic control than those with few readings (more than five readings per day vs. less than four readings per day: HbA1c, 7.2 +/- 1.1% vs. 8.0 +/- 0.9%; mean daily blood glucose, 151 +/- 22 mg/dL vs. 176 +/- 30 mg/dL; percentage of readings per month >300 mg/dL, 10 +/- 4% vs. 14 +/- 5%; percentage of readings in target range [80-180 mg/dL], 59% vs. 48% [P<0.05 in all cases]) and had a lower glycemic variability (J-score, 49 +/- 13 vs. 71 +/- 25 [P<0.05]; Hyperglycemia Index, 0.9 +/- 0.5 vs. 1.9 +/- 1.2 [P<0.05]; Index of Glycemic Control, 1.9 +/- 0.8 vs. 3.1 +/- 1.6 [P<0.05]; Hypoglycemia Index, 0.9 +/- 0.8 vs. 1.2 +/- 1.3 [not significant]). Frequent self-monitoring of blood glucose was associated with a higher number of bolus applications (6.1 +/- 2.2 boluses/day vs. 4.5 +/- 2.0 boluses/day [P<0.05]). Therefore, a similar but less pronounced effect on glycemic variability in favor of more daily bolus applications was observed (more than five vs. less than four bolues per day: J-score, 57 +/- 17 vs. 63 +/- 25 [not significant]; Hypoglycemia Index, 1.0 +/- 1.0 vs. 1.5 +/- 1.4 [P<0.05]; Hyperglycemia Index, 1.3 +/- 0.6 vs. 1.6 +/- 1.1 [not significant]; Index of Glycemic Control, 2.3 +/- 1.1 vs. 3.1 +/- 1.7 [P<0.05]). Conclusions: Pump users who perform frequent daily glucose readings have a better glycemic control with lower glycemic variability.
引用
收藏
页码:392 / 397
页数:6
相关论文
共 19 条
[1]   Continuous subcutaneous insulin infusion - A new way to lower risk of severe hypoglycemia, improve metabolic control, and enhance coping in adolescents with type 1 diabetes [J].
Boland, EA ;
Grey, M ;
Oesterle, A ;
Fredrickson, L ;
Tamborlane, WV .
DIABETES CARE, 1999, 22 (11) :1779-1784
[2]   Insulin pump therapy in adults [J].
Didangelos, Triantafillos ;
Iliadis, Fotios .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2011, 93 :S109-S113
[3]  
Hill NR, 2003, DIABETIC MED, V24, P753
[4]   Comparison of the effects of continuous subcutaneous insulin infusion (CSII) and NPH-based multiple daily insulin injections (MDI) on glycaemic control and quality of life: results of the 5-nations trial [J].
Hoogma, RPLM ;
Hammond, PJ ;
Gomis, R ;
Kerr, D ;
Bruttomesso, D ;
Bouter, KP ;
Wiefels, KJ ;
de la Calle, H ;
Schweitzer, DH ;
Pfohl, M ;
Torlone, E ;
Krinelke, LG ;
Bolli, GB .
DIABETIC MEDICINE, 2006, 23 (02) :141-147
[5]  
Kovatchev B.P., 2001, J THEORETICAL MED, V3, P1
[6]  
Kovatchev Boris P, 2005, Diabetes Technol Ther, V7, P849, DOI 10.1089/dia.2005.7.849
[7]   Evaluation of a new measure of blood glucose variability in diabetes [J].
Kovatchev, Boris P. ;
Otto, Erik ;
Cox, Daniel ;
Gonder-Frederick, Linda ;
Clarke, William .
DIABETES CARE, 2006, 29 (11) :2433-2438
[8]  
Kovatchev Boris P, 2003, Diabetes Technol Ther, V5, P817, DOI 10.1089/152091503322527021
[9]   Evidence of a Strong Association Between Frequency of Self-Monitoring of Blood Glucose and Hemoglobin A1c Levels in T1D Exchange Clinic Registry Participants [J].
Miller, Kellee M. ;
Beck, Roy W. ;
Bergenstal, Richard M. ;
Goland, Robin S. ;
Haller, Michael J. ;
McGill, Janet B. ;
Rodriguez, Henry ;
Simmons, Jill H. ;
Hirsch, Irl B. .
DIABETES CARE, 2013, 36 (07) :2009-2014
[10]   Frequency of blood glucose testing in well educated patients with diabetes mellitus type 1: How often is enough? [J].
Minder, Anna Elisabeth ;
Albrecht, Dominique ;
Schaefer, Juliane ;
Zulewski, Henryk .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2013, 101 (01) :57-61