A real-time, quantitative PCR method using hydrolysis probes for the monitoring of Plasmodium falciparum load in experimentally infected human volunteers

被引:83
作者
Rockett, Rebecca J.
Tozer, Sarah J.
Peatey, Chris [1 ]
Bialasiewicz, Seweryn
Whiley, David M.
Nissen, Michael D.
Trenholme, Katharine [1 ]
Mc Carthy, James S. [2 ]
Sloots, Theo P.
机构
[1] Queensland Inst Med Res, Malaria Biol Lab, Brisbane, Qld 4006, Australia
[2] Univ Queensland, Queensland Inst Med Res, Clin Trop Med Lab, Brisbane, Qld 4072, Australia
来源
MALARIA JOURNAL | 2011年 / 10卷
关键词
POLYMERASE-CHAIN-REACTION; MALARIA PARASITES; BLOOD;
D O I
10.1186/1475-2875-10-48
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: The accurate quantification of Plasmodium falciparum parasite numbers by PCR is an important tool for monitoring growth kinetics in subjects infected and subsequently treated with anti-malarial agents. Methods: A real-time quantitative PCR (rt-qPCR) method using primers and a hydrolysis probe that targets the 18S rRNA gene was adapted and optimized to estimate parasite load in blood samples. Samples included laboratory prepared blood samples of varying parasite concentrations (6.4 x 10(5) to 6.4 parasites per 500 mu l of packed red blood cells (500pRBC)) and blood samples collected from an experimentally infected human subject collected at 19 time points over 10 days. Sample preparation and extraction, detection chemistry, assay reproducibility, and limit of detection were compared to a previously published SYBR Green rt-qPCR used in a malaria vaccine clinical trial. Results: Both the rt-qPCR hydrolysis probe assay and SYBR Green rt-qPCR provided a limit of detection of 6.4 x 101 parasites per 500pRBC. However non-specific amplification in the SYBR Green rt-qPCR assay led to either inaccurate estimation of parasite load at levels below 6.4 x 102 parasites per 500pRBC and to false-positive detection of parasites in negative samples. The rt-qPCR hydrolysis probe assay was specific and provided reliable quantification of parasitaemia down to 6.4 x 10(1) parasites per 500pRBC. Notably, 12 of the 19 consecutive samples collected from the experimentally infected subject were at or below 6.4 x 10(2) copies per 500pRBC. Conclusions: These results show that the hydrolysis probe rt-qPCR assay is superior to the SYBR Green rt-qPCR for the quantification of P. falciparum in human blood samples. The hydrolysis probe rt-qPCR is now in use in the Queensland paediatric infectious diseases laboratory (QPID) to monitor parasitaemia in experimentally-infected clinical trial subjects.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Prevalence of Plasmodium falciparum and P. vivax in an area of transmission located in Para State, Brazil, determined by amplification of mtDNA using a real-time PCR assay
    Souza, C. R. T.
    Carvalho, T. A. A.
    Amaral, R. C. G.
    Cunha, L. S.
    Cunha, M. G.
    Guerreiro, J. F.
    GENETICS AND MOLECULAR RESEARCH, 2012, 11 (03) : 3409 - 3413
  • [42] A DNA Real-Time Quantitative PCR Method Suitable for Routine Monitoring of Low Levels of Minimal Residual Disease in Chronic Myeloid Leukemia
    Bartley, Paul A.
    Latham, Susan
    Budgen, Bradley
    Ross, David M.
    Hughes, Elizabeth
    Branford, Susan
    White, Deborah
    Hughes, Timothy P.
    Morley, Alexander A.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2015, 17 (02) : 185 - 192
  • [43] Genome Mininge-Based Identification of Identical Multirepeat Sequences in Plasmodium falciparum Genome for Highly Sensitive Real-Time Quantitative PCR Assay and Its Application in Malaria Diagnosis
    Raju, Lolabattu S.
    Kamath, Shwetha
    Shetty, Manjunatha C.
    Satpathi, Sanghamitra
    Mohanty, Akshaya K.
    Ghosh, Susanta K.
    Kolluri, Nikunja
    Klapperich, Catherine M.
    Cabodi, Mario
    Padmanaban, Govindarajan
    Nagaraj, Viswanathan A.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2019, 21 (05) : 824 - 838
  • [44] Field evaluation of the photo-induced electron transfer fluorogenic primers (PET) real-time PCR for the detection of Plasmodium falciparum in Tanzania
    Talundzic, Eldin
    Maganga, Mussa
    Masanja, Irene M.
    Peterson, David S.
    Udhayakumar, Venkatachalam
    Lucchi, Naomi W.
    MALARIA JOURNAL, 2014, 13
  • [45] Reference gene selection for gene expression studies in lily using quantitative real-time PCR
    Zhang, M. F.
    Liu, Q.
    Jia, G. X.
    GENETICS AND MOLECULAR RESEARCH, 2016, 15 (02)
  • [46] Development, Application, and Results of Routine Monitoring of Marek's Disease Virus in Broiler House Dust Using Real-Time Quantitative PCR
    Walkden-Brown, Stephen W.
    Islam, Aminul
    Groves, Peter J.
    Rubite, Ambrosio
    Sharpe, Sue M.
    Burgess, Susan K.
    AVIAN DISEASES, 2013, 57 (02) : 544 - 554
  • [47] Chimerism Monitoring after Allogeneic Hematopoietic Stem Cell Transplantation Using Quantitative Real-Time PCR of Biallelic Insertion/Deletion Polymorphisms
    Kim, Seon Young
    Jeong, Moon Hwan
    Park, Nare
    Ra, Eunkyoung
    Park, Hyunwoong
    Seo, Soo Hyun
    Kim, Ji Yeon
    Seong, Moon-Woo
    Park, Sung Sup
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2014, 16 (06) : 679 - 688
  • [48] Highly Sensitive Quantitative Real-Time PCR for the Detection of Plasmodium Liver-Stage Parasite Burden following Low-Dose Sporozoite Challenge
    Schussek, Sophie
    Groves, Penny L.
    Apte, Simon H.
    Doolan, Denise L.
    PLOS ONE, 2013, 8 (10):
  • [49] A sensitive, specific and reproducible real-time polymerase chain reaction method for detection of Plasmodium vivax and Plasmodium falciparum infection in field-collected anophelines
    Bickersmith, Sara A.
    Lainhart, William
    Moreno, Marta
    Chu, Virginia M.
    Vinetz, Joseph M.
    Conn, Jan E.
    MEMORIAS DO INSTITUTO OSWALDO CRUZ, 2015, 110 (04): : 573 - 576
  • [50] Specific Detection of Rinderpest Virus by Real-Time Reverse Transcription-PCR in Preclinical and Clinical Samples from Experimentally Infected Cattle
    Carrillo, C.
    Prarat, M.
    Vagnozzi, A.
    Calahan, J. D.
    Smoliga, G.
    Nelson, W. M.
    Rodriguez, L. L.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (11) : 4094 - 4101